MA40-704x Series, MA41-707x Series, and MA41-715x Series
S p e c i f i c a t i o n s
Inputs
|
Control signal |
On-off SPST contacts or Triacs (500 mA). |
|
|
Power |
Refer to Model Chart. |
|
|
|
|
|
|
Connections |
3 ft. (0.9 m) long, appliance cable, 1/2 in. conduit connectors. For M20 Metric conduit, use AM-756 |
|
|
adaptor. |
||
|
|
||
|
|
||
Outputs |
|
||
|
|
|
|
|
Motor Type |
MA40-704x, MA41-707x: Brush. |
|
|
MA41-715x: Brushless DC. |
||
|
|
||
|
|
|
|
|
|
MA40-7043-501: One auxiliary switch available, SPDT 6A resistive @ 24 Vac, adjustable 0 to 95 (0 to |
|
|
|
1 scale). UL listed, switch meets VDE requirements for 6 (1.5)A, 24 Vac. |
|
|
|
MA40-7040-501 or MA40-7041-50: One auxiliary switch available, SPDT 6A resistive @ 240 Vac, |
|
|
Electrical |
adjustable 0 to 95 (0 to 1 scale). UL listed, switch meets VDE requirements for 6 (1.5)A, 24 Vac. |
|
|
|
MA41-715x-502 or MA41-707x-502: Two auxiliary switches available, SPDT 7A resistive @ 250 Vac, |
|
|
|
one fixed @5 and one adjustable 25 to 85 . UL Listed, meets VDE requirements for 7 (2.5)A, 250 |
|
|
|
Vac. |
|
|
|
|
|
|
|
Direction of rotation: CW or CCW rotation is available through reverse mounting. |
|
|
|
|
|
|
|
Shaft clamp: Direct coupled using a through hole output hub. |
|
|
|
MA40-704x: Up to 5/8 in. round, 1/2 in. square shafts. |
|
|
Mechanical |
MA41-71xx: Up to 3/4 in. round, 1/2 in. square shafts. |
|
|
See Accessories for larger shaft options. |
||
|
|
||
|
|
|
|
|
|
Position Indicator: MA40-704x: Visual indicator, 0 to 1 (0 is the spring return position). |
|
|
|
MA41-707x, MA41-715x: Pointer (-5 to 90°) and scale are provided for position indication (-5 is normal |
|
|
|
or spring return position). |
|
|
|
||
Environment |
|
||
|
|
|
|
|
Ambient Temperature limits |
Shipping and storage: -40 to 160 F (-40 to 71 C). |
|
|
Operating: -22 to 140 F (-30 to 60 C). |
||
|
|
||
|
|
|
|
|
Humidity |
5 to 95% RH, non-condensing. |
|
|
|
|
|
|
|
MA40-704x: NEMA 2 (IEC 1P54) no restrictions. |
|
|
|
|
|
|
Locations |
MA41-707x: NEMA 1 (IEC IP30), NEMA 2 (IEC IP54) with conduit in the down position. |
|
|
|
|
|
|
|
MA41-715x: NEMA 1 (IEC IP30), NEMA 2 (IEC IP54) with conduit in the down position. |
|
|
|
|
|
Dimensions |
MA41-707x, MA41-715x: 10-1/2 H x 4 W x 3-1/2 D in. (287 x 100 x 89 mm). |
||
MA40-704x: 6-51/64 H x 4 W x 3-1/2 D in. (68 x 100 x 89 mm). |
|||
|
|
||
|
|
||
Agency Listings |
|
||
|
|
|
|
|
UL |
UL-873, Underwriters Laboratories Listed (File #E9429 Category Temperature-Indicating and |
|
|
Regulating Equipment). |
||
|
|
||
|
|
|
|
|
European Community |
EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). |
|
|
|
|
|
|
CUL |
Canadian Standards C22.2 No. 24-93. |
|
|
|
|
|
|
Australia |
This product meets requirements to bear the C-Tick mark according to the terms specified by the |
|
|
Communications Authority under the Radio Communications Act 1992. |
||
|
|
||
|
|
||
General Instructions |
Refer to F-26642. |
||
|
|
|
80 |
© Copyright 2006 TAC. All Rights Reserved. |