The weather station is intended for temperature and relative humidity level measurement. Use the main unit to measure indoor parameters and the remote sensor for outdoor or indoor measurement. Besides, the unit displays current time and date and has a built-in alarm clock.

DESCRIPTION

Main unit

1.«MAX/MIN» button

2.«▼» button

3.«SNOOZE-LIGHT» button

4.«ALARM» button

5.«▲» button

6.«SET» button

7.Sensor wall mounting hole

8.Battery compartment lid

9.Flap stand

Display

10.Remote temperature sensor indication «OUTDOOR»

11.Integrated temperature and humidity sensor indication «INDOOR»

12.Current time indication

Remote sensor

13.Sensor

14.Display

15.Sensor wall mounting hole

16.Temperature measurement unit selection buttons «°C/°F»

17.Battery compartment lid

18.Stand

19.Wired temperature sensor

SAFETY MEASURES

Before using the unit, read this instruction manual carefully and keep it for future reference.

Use the unit for intended purposes only, as specified in this manual. Mishandling the unit can lead to its breakage and cause harm to the user or damage to his/her property.

Do not subject the unit to impacts (dust and moisture are also to be avoided), as it can lead to failures, reduction of service life, battery damage and to deformation of the unit body parts.

Provide that no liquid gets inside the unit body. To prevent the unit’s damage, do not expose it to rain or moisture, do not place the unit in places with high humidity (near bathtubs, containers filled with water, kitchen sinks, washing machines, near a swimming pool, in wet basements, etc.). Protect the unit from dripping and splashing.

The unit should not be placed near heat sources such as radiators, electric heaters, stoves, or in places exposed to direct sunlight, excessive dust, vibration or mechanical shocks.

Install the unit on flat stable surface in places with proper ventilation. Do not block the unit ventilation openings.

Make sure that the wired sensor is not bent or pinched.

Do not let foreign objects get into the unit openings.

Do not repair the unit or make any changes in it by yourself. If you find any damages, switch the unit off by removing the batteries from the battery compartment and apply to the authorized service center.

If you disassemble the unit, it will lead to warranty cancellation. No parts inside the unit require the user’s attention.

This unit is not intended for usage by children under 8 years of age.

Children aged 8 and over as well as disabled persons can use this unit only under supervision of a person who is responsible for their safety, if they are given all the necessary and understandable instructions concerning the safe usage of the unit and information about danger that can be caused by its improper usage.

Do not leave children unattended to prevent using the unit as a toy.

For children safety reasons, do not leave polyethylene bags used as packaging unattended.

Attention! Do not allow children to play with polyethylene bags or packaging film. Danger of suffocation!

Do not disassemble the unit by yourself, if any malfunction is detected or after the unit was dropped, apply to the nearest authorized service center.

Do not use abrasives or substances causing damages of the body and the inner parts of the units for cleaning.

2

Transport the unit in the original package only.

Keep the unit out of reach of children and disabled persons.

THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY

BEFORE THE FIRST USE

After unit transportation or storage under cold (winter) conditions, it is necessary to keep it for at least two hours at room temperature before switching on.

Unpack the unit, remove any stickers that can prevent unit operation.

Check the unit for damages. In case of damages do not switch the unit on.

BATTERY INSTALLATION Attention!

Batteries leakage can cause injuries or the unit damage. To avoid damages, follow the recommendations specified below:

insert batteries following the polarity;

use only new batteries of the type specified in the instruction manual;

do not insert batteries of different types, new batteries with old ones, batteries of different brands as well as rechargeable batteries of different capacity;

remove the batteries if you are not planning to use the unit for a long time;

do not dismantle the batteries, do not subject them to high temperatures;

replace the batteries in time.

Notes:

If the batteries are already installed into the battery compartment, you need to remove the isolation insert.

Long operation under low or high temperatures can reduce the voltage of the batteries of the sensor (13), thus decreasing the transmission range.

If the symbols’ contrast on the display has significantly reduced, replace the batteries.

Remote sensor

Shift the battery compartment lid (17). Insert two “AAA” batteries (included), strictly following the polarity.

Select the temperature measurement units by pressing the button (16). The selected measurement units are shown on the display (14).

Install the battery compartment lid (17) back to its place.

Main unit

Remove the battery compartment lid (8) and insert two “AAA” batteries (included), strictly following the polarity.

Install the battery compartment lid (8) back to its place.

UNIT INSTALLATION

Use the flap stand (9) to set the main unit on a flat stable surface, use the stand (18) for the remote sensor (13).

You can also hang the main unit and the sensor

(13)on the wall by using the holes (7) and (15), respectively.

Place the remote sensor (13) outdoors so that it is not exposed to direct sunlight, rain or snow. The sensor is installed up to 30 meters away from the main unit in the line of sight. The distance from the main unit and the sensor to any interference sources (such as computers, television receivers etc.) should be at least 1,5-2 meters.

Do not place the unit near metal frames and do not use appliances (for example, headphones) operating at the same frequency (433 MHz) near the weather station.

The remote sensor (13) operates within the temperature range from –40°С до +60°С. If the outdoor temperature is below -20 °C or if the remote sensor

(13)can’t be installed outside, set it indoors and install the wired sensor (19) outside.

Note: Make sure that the wired sensor (19) is not bent or pinched.

DATE AND TIME SETTING

Note: If the buttons (2) and (5) are not pressed within 30 seconds during the setting process, the unit will be switched to the current time mode without saving the new settings.

Press and hold the SET button (6) for 2 seconds, the time indication format symbols (12 hour format or 24 hour format) will be flashing in the field (12).

Use the buttons (2) ▼ and (5) ▲ to set the time indication format.

Press the SET button (6), the hour digits will be flashing in the field (12).

Use the buttons (2) ▼ and (5) ▲ to set time in

hours. To set the afternoon time in the 12 hour format, press the buttons (2) ▼ and (5) ▲ until the symbol «PM» appears.

Press the SET button (6), the minute digits will be flashing.

Use the buttons (2) ▼ and (5) ▲ to set time in minutes.

Press the SET button (6), the year digits will be flashing.

Use the buttons (2) ▼ and (5) ▲ to set the necessary year.

Press the SET button (6), the month digits will be flashing.

Use the buttons (2) ▼ and (5) ▲ to set the necessary month.

Press the SET button (6), the day digits will be flashing.

Use the buttons (2) ▼ and (5) ▲ to set the day.

To save the settings, press the SET button (6).

ALARM SETTING

Note: If the buttons (2) and (5) are not pressed within 30 seconds during the setting process, the unit will be switched to the current time mode without saving the new settings.

To view the alarm settings, press the ALARM button (4).

To change the settings, press the ALARM button

(4)again and hold it down for 2 seconds while in the alarm settings displaying mode. The alarm hour digits will be flashing.

Use the buttons (2) ▼ and (5) ▲ to set the alarm time in hours.

Press the ALARM button (4), the alarm minute digits will be flashing.

Use the buttons (2) ▼ and (5) ▲ to set the alarm time in minutes.

To save the settings, press the ALARM button (4).

To switch the alarm on/off, enter the alarm settings displaying mode by pressing the ALARM button (4). While the alarm settings are shown on the display,

press the ALARM button (4) again. If the alarm is on, the symbol appears on the display.

Repeating alarm signal

The alarm signal will sound for 2 minutes if you do not press any buttons.

You can switch the alarm signal off for 5 minutes by pressing the SNOOZE button (3). The symbol «Zz» will appear on the display, the alarm signal will be repeated in 5 minutes.

To switch the alarm sound signal off, press any other button.

DISPLAY BACKLIGHT

To switch the display backlight on, press the SNOOZELIGHT button (3). The backlight will be on for 10 seconds.

TEMPERATURE AND HUMIDITY MEASUREMENT

The integrated thermometer is used for indoor temperature measurement within the range from 0 °С to +50°С, the remote sensor (13) is used for outdoor temperature measurement within the range from -40°C to +60° C. The integrated humidity meter operates within the relative humidity range from 20% to 90%. If the temperature and humidity values are below the specified range, the symbols «LL» will be shown in the corresponding field.

The outdoor temperature values are displayed in the field (10) «OUTDOOR». The indoor temperature and humidity data are displayed in the field (11) «INDOOR».

Temperature and relative humidity levels are measured every 30 seconds by the unit, and the outdoor temperature is measured minutely. The data are updated automatically.

Measurement unit selection

To select the measurement units (Celsius or Fahrenheit degrees), press the button (2) ▼.

Remote sensor data transmission

When the batteries are inserted in the remote sensor (13), it will start data transmission with an about 1-minute interval.

If the batteries are inserted in the main unit, the unit will start searching the signal from the remote sen-

sor (13). During the search the symbol

is shown

on the display of the main unit.

 

The signal search takes about 3 minutes. Data obtained from the remote sensor (13) will be shown in the field (10) «OUTDOOR».

If there is no remote sensor signal, the symbols «- -. -» will be shown in the field (10) «OUTDOOR».

To start a new search, press and hold down the button (5) ▲ for 2 seconds.

Memory function

The unit memory stores the data on maximal and minimal temperature and relative humidity values for the current day. When a new day comes at 0:00, the data for the previous day are deleted from the unit memory.

Press the MAX/MIN button (1) repeatedly to view:

the maximal temperature and humidity values (the symbol «MAX» in the corresponding field),

the minimal values (the symbol «MIN»),

the current values.

Maximal or minimal temperature and humidity values are shown on the display within 10 seconds.

To clear the unit memory, press and hold down the MAX/MIN button (1) while in the maximal or minimal values displaying mode.

CLEANING AND CARE

Switch the unit off before cleaning by removing the batteries from the battery compartment of the main unit and the remote sensor.

Use a soft cloth to clean the unit.

Do not use liquid or aerosol detergents to clean the unit.

STORAGE

Unplug and clean the unit before taking it away for storage.

Wind the wired temperature sensor (19). Do not wind the sensor wire around the unit.

Keep the unit away from children in a dry cool place.

DELIVERY SET

Weather station main unit – 1 pc. Remote sensor – 1 pc.

«ААА» batteries – 4 pcs. Instruction manual – 1 pc.

TECHNICAL SPECIFICATIONS

Measurements

Main unit

From 0oС to +50oС

Remote sensor

from -40oС to +60oС

Temperature measurement

0,1oС

precision

 

Relative humidity

from 20% to 90%

measurement

 

Relative humidity

1%

measurement precision

 

Remote sensor data transmission

Transmission frequency

433 MHz

Number of sensors

1

connected

 

Transmission range

Maximum 30 m

Power supply

 

Main unit

2 «ААА» type batteries

1,5 V

 

Remote sensor

2 «ААА» type batteries

1,5 V

 

The manufacturer preserves the right to change the specifications of the unit without a preliminary notification

Unit operating life is 3 years

Guarantee

Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

This product conforms to the EMCRequirements as laid down by the Council Directive 2004/108/ЕС and to the Low Voltage Regulation (2006/95/ЕС)