Vitek VT-3538 SR User Manual [ru]

0 (0)
Vitek VT-3538 SR User Manual

ENGLISH

WIRELESS WEATHER STATION

DESCRIPTION

Main unit

1.«DOWN» button

2.«UP» button

3.«MODE» button

4.«ALARM» button

5.«TEMP ALERT» button

6.«SNOOZE-LIGHT» button

7.Current time projector

8.Battery compartment lid

9.AC/DC adapter connection socket 23.Power adapter

Display

10.Current time indication

11.Field of weather and atmospheric pressure indications

12.Temperature and humidity remote sensor indication «OUTDOOR»

13.Week day field

14.Integrated temperature and humidity sensor indication «INDOOR»

Remote sensor

15.Sensor

16.Display

17.Sensor wall mounting hole

18.Battery compartment lid

19.Stand

20.Temperature measurement unit selection buttons «°C/°F»

21.Transmission channel number selection button «CH»

22.Wired temperature sensor

SAFETY MEASURES

Before using the unit, read this instruction manual carefully and keep it for future reference.

Use the unit for intended purposes only, as specified in this manual. Mishandling the unit can lead to its breakage and cause harm to the user or damage to his/her property.

Before using the unit, make sure that your home mains voltage corresponds to the operating voltage of the unit.

The adapter cord should not:

touch hot objects,

run over sharp edges,

be used for carrying the unit.

Check the power adapter cord integrity periodically.

When using the unit, we recommend to unwind the power adapter cord to its full length.

Do not subject the units to impacts (dust and moisture are also to be avoided), as it can lead to failures, reduction of service life, battery damage and to deformation of the unit body parts.

Provide that no liquid gets inside the unit body. To prevent unit damage do not expose the unit to rain or moisture, do not put it in places with high humidity (near bath tubs, containers filled with water, kitchen sinks, washing machines, near a swimming pool, in wet basements, etc.). Prevent the unit from dripping and splashing.

The unit should not be placed near heat sources such as radiators, electric heaters, stoves, or in places exposed to direct sunlight, excessive dust, vibration or mechanical shocks.

Install the station on flat stable surface in places with proper ventilation. Do not block the ventilation openings of the unit.

Make sure that the wired sensor is not bent or pinched.

Do not let foreign objects get into unit openings.

Do not repair the unit or make any changes in it by yourself. If you find any damages, switch the unit off by removing the batteries from the battery compartment and apply to the authorized service center.

If you disassemble the unit, it will lead to warranty cancellation. No parts inside the unit require the user’s attention. Unplug the unit after every usage and before cleaning.

When unplugging the power adapter, do not pull the power cord, but hold the adapter.

For children safety reasons do not leave polyethylene bags, used as a packaging, unattended.

Attention! Do not allow children to play with polyethylene bags or packaging film. Danger of suffocation!

Do not allow children under 8 years of age to touch the unit body, the power adapter or the power cord during operation of the unit.

Do not leave children unattended to prevent using the unit as a toy.

Close supervision is necessary when children under 8 years of age or disabled persons are near the operating unit.

This unit is not intended for usage by children under 8 years of age.

Children aged 8 and over as well as disabled persons can use this unit only under supervision of a person who is responsible for their safety, if they are given all the necessary and understandable instructions concerning the safe usage of the unit and information about danger that can be caused by its improper usage.

To avoid damages, transport the unit in original package only.

Keep the unit out of reach of children.

THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY

BEFORE USING THE UNIT FOR THE FIRST TIME

After unit transportation or storage under cold (winter) conditions, it is necessary to keep it for at least two hours at room temperature before switching on.

Unpack the unit, remove any stickers that can prevent unit operation.

Check the unit for damages. In case of damages do not switch it on.

DEVICE CONNECTION Attention!

Batteries leakage can cause injuries or damage of the device. To avoid damages, follow the recommendations specified below:

insert batteries following the polarity;

use only new batteries of the type specified in the instruction manual;

do not insert batteries of different types, new batteries with old ones, batteries of different brands as well as rechargeable batteries of different capacity;

remove the batteries if you are not planning to use the device for a long time;

do not dismantle the batteries, do not subject them to high temperatures;

replace the batteries in time.

Notes:

If the batteries are already installed into the battery compartment, you need to remove the isolation insert.

Long operation under low or high temperatures can reduce the voltage of the batteries of the sensor (15), thus decreasing the sensor’s transmission range.

Remote sensor

Shift the battery compartment lid (18). Insert two “AAA” batteries (included), strictly following the polarity.

Use the °C/°F button (20) to select the temperature measurement units. The selected measurement units are shown on the display (16).

Select the transmission channel number (from 1 to 3) by pressing the CH button (21) consequently.

Install the battery compartment lid (18) back to its place.

Installation of batteries into the main unit

Remove the battery compartment lid (8) and insert three “AA” batteries (included), strictly following the polarity.

Install the battery compartment lid (8) back to its place.

Connecting the main unit to the mains

You can connect the main unit directly to the mains using the power adapter (23).

Before switching the unit on, make sure that your home mains voltage corresponds to unit operating voltage.

Unwind the power adapter cord to its full length.

Insert the power adapter jack into the socket (9) and connect the adapter to the mains socket.

UNIT INSTALLATION

Place the main block and the remote sensor (15) on a flat steady surface. Use the stand (19) to set the remote sensor (15).

You can also hang the remote sensor (15) on the wall by using the hole (17).

Place the remote sensor (15) outdoors so that the sensor (15) is not exposed to direct sunlight, rain or snow. The remote sensor is installed up to 30 meters away from the main unit in the line of sight. The distance from the main unit and the remote sensor to any interference sources (such as computers, television receivers etc.) should be at least 1,5-2 meters.

Do not place the unit near metal frames and do not use appliances (for example, headphones) operating at the same frequency range (433 MHz) near the weather station.

The remote sensor (15) operates at the temperature from –40°C to +60° C. If the outdoor temperature is below -20 °C or if the remote sensor (15) can’t be installed outside, set it indoors and install the wired temperature sensor (22) outside. In this case

outdoor temperature and indoor humidity (at the remote sensor installation point) are displayed in the field (12).

Note: Make sure that the wired temperature sensor (22) is not bent or pinched.

DATE, TIME, TEMPERATURE AND PRESSURE MEASUREMENT UNITS SETTING

Notes:

The available languages for week day indication: English (EN), German (GE), Italian (IT), French (FR), Dutch (NE), Spanish (ES) and Danish (DA).

If the buttons (2) UP and (1) DOWN are not pressed within 30seconds during the setting process, the unit will be switched to the current time mode without saving the new settings.

Press and hold down the MODE button (3) for 2 seconds, the year numerical value will start flashing in the field (10).

Use the buttons (2) UP and (1) DOWN to set the required year.

Press the MODE button (3), the month numerical value will be flashing in the field (10).

Use the buttons (2) UP and (1) DOWN to set the required month.

Press the MODEbutton (3), the day numerical value will be flashing.

Use the buttons (2) UP and (1) DOWN to set the day.

Press the MODE button (3), the time indication format symbols (12 hour format or 24 hour format) will be flashing.

Use the buttons (2) UP and (1) DOWN to select the time indication format.

Press the MODE button (3), the hours digits will be flashing.

Use the buttons (2) UP and (1) DOWN to set time in hours.

Press the MODE button (3), the minute digits will be flashing.

Use the buttons (2) UP and (1) DOWN to set the time in minutes.

Press the MODE button (3), the language symbol used for week day indication will be flashing.

Use the buttons (2) UP and (1) DOWN to set the language for week day indication (for example, English).

Press the MODE button (3), the temperature measurement unit symbols will be flashing: «°С» - Celsius degrees or «°F» – Fahrenheit degrees.

Use the buttons (2) UP and (1) DOWN to select the temperature measurement units.

Press the MODE button (3), the pressure measurement unit symbols will be flashing: «hPa» - hectopascals or «inHg» - Hg millimeters.

Use the buttons (2) UP and (1) DOWN to select the pressure measurement units.

2

To save the settings, press the MODE button (3).

After the date is set, the corresponding week day will be displayed in the field (13). See the symbols interpretation below.

DAYS OF WEEK

Day of

Eng-

Ger-

Ital-

French

Dutch

Spanish

Danish

week/

lish

man

ian

lan-

(EN)

(GE)

(IT)

(FR)

(NE)

(ES)

(DA)

guage

 

 

 

 

 

 

 

Mo.

MO

MO

LU

LU

MA

LU

MA

Tu.

TU

DI

MA

MA

DI

MA

TI

We.

WE

MI

ME

ME

WO

MI

ON

Th.

TH

DO

GI

JE

DO

JU

TO

Fr.

FR

FR

VE

VE

VR

VI

FR

Sa.

SA

SA

SA

SA

ZA

SA

LO

Su.

SU

SO

DO

DI

ZO

DO

SO

PROJECTOR

The projector is used for displaying the current time. Set the unit at a 3 meter distance from the surface on which the image is projected. If the main unit is powered by batteries, switch the projector on by pressing the SNOOZE/LIGHT button (6). The projector illumination will be on for 5 seconds.

If the unit is powered by the adapter, the projector illumination will light constantly.

To rotate the projected image by 180°, press the SNOOZE/LIGHT button (6) and hold it down for 5 seconds.

ALARM SETTING

Note: If the buttons (2) UP and (1) DOWN are not pressed within 30 seconds during the setting process, the unit will be switched back to the current time mode.

To set the alarm, press and hold down the ALARM button (4) for 2 seconds, the first alarm hour digits will be flashing.

Use the buttons (2) UP and (1) DOWN to set the first alarm time in hours.

Press the ALARM button (4), the first alarm minute digits will be flashing.

Use the buttons (2) UP and (1) DOWN to set the first alarm time in minutes.

Press the ALARM button (4), the second alarm hour digits will be flashing.

Use the buttons (2) UP and (1) DOWN to set the second alarm time in hours.

Press the ALARM button (4), the second alarm minute digits will be flashing.

Use the buttons (2) UP and (1) DOWN to set the second alarm time in minutes.

To save the settings, press the ALARM button (4).

To switch the alarm(s) on/off, press the DOWN button (1) while

in the alarm setting mode until the symbols

appear

in the field (10).

 

Alarm snooze

The alarm signal will sound for 2 minutes if you do not press any buttons.

You can switch the alarm signal off for 5 minutes by pressing the SNOOZE/LIGHT button (6). The symbol «Zz» will appear on the display, the alarm signal will be repeated in 5 minutes.

To switch the alarm signal off, press any other button.

DISPLAY BACKLIGHT

If the unit is powered by batteries, switch the display backlight on by pressing the SNOOZE/LIGHT button (6). The backlight will be on for 5 seconds.

If the unit is powered by the adapter, the display backlight will light constantly.

TEMPERATURE, HUMIDITY AND ATMOSPHERIC PRESSURE MEASUREMENT

Thermometer integrated in the main unit is used for temperature measurement within the range from 0 °С to +50°С, and the remote sensor (15) is used outdoors at the temperature from -40°С to +60°С. Indoor temperature and humidity indications are shown in the field (14) «INDOOR».

The humidity meters (of the main unit and remote sensor) operate within the relative humidity range from 20% to 90%.

Outdoor temperature and humidity indications are shown in the field (12) «OUTDOOR».

Temperature and relative humidity levels are measured every 30 seconds by the main unit, and minutely by the remote sensor (15). The data are updated automatically.

Remote sensor data transmission

When the batteries are inserted in the remote sensor (15), it will start data transmission.

After you set the batteries in the main unit, select the transmission channel number. For this press the UP button (2) consequently. The selected main unit channel number should match the channel number on the display (16) of the remote sensor (15).

The signal search takes about 3 minutes. If there is no remote sensor signal, the symbols «- -. -» will be shown in the field (12) «OUTDOOR». -».

To start a new search, press and hold down the UP button (2) for 2 seconds.

Note: You can connect the unit with two additional sensors operating on the frequency of 433 MHz. To do so every sensor should be assigned its own channel number (from 1 to 3). To view data from different sensors, press the UP button (2) consequently. If a sensor does not support the humidity measurement function, the symbols «- - -» will be shown in the field (12) «OUTDOOR» in humidity value.

Memory function

The unit memory keeps the data of maximal and minimal temperature values and relative humidity level.

Consequently press the DOWN button (1) to view:

the maximal temperature and humidity values (the symbol «MAX» in the corresponding field),

the minimal values (the symbol «MIN»),

the current values.

To clear the unit memory, press and hold the DOWN button (1) for 2 seconds while the unit is in the maximal or minimal value displaying mode.

Warning signal of temperature change

If the outdoor temperature is out of the range preset by you, the unit will give a tone signal.

To set the alert signal, press and hold down the TEMP ALERT button (5) for 2 seconds while in current time mode.

The temperature range upper limit symbol

will appear

on the display.

 

Use the buttons (2) UP and (1) DOWN to set the upper limit of the temperature range.

Press the TEMP ALERT button (5), the temperature range lower

limit symbol

will appear.

Use the buttons (2) UP and (1) DOWN to set the lower limit of the temperature range.

To save the settings, press the TEMP ALERT button (5).

To switch the alert signal on/off, press the TEMP ALERT button

(5) in the current time mode. The symbols

indicate

that the alert is on.

 

When the temperature is out of the preset range, you will hear a sound signal. To switch the signal off, press any button. If

you don’t press any button for 1 minute, the sound signal will be switched off, but the corresponding signal or

will be flashing on the display until the outdoor temperature is within the preset range.

Note: If the outdoor temperature is below 0°С, the warning symbol will appear on the display.

WEATHER FORECAST AND ATMOSPHERIC PRESSURE MEASUREMENT

The atmospheric pressure is measured every 15 minutes. The atmospheric pressure trends are indicated with arrows in the field (11). Weather forecast data are updated every hour. The following weather indications (depending on the temperature and humidity data received from the remote sensor) are shown on the display:

sunny

mainly clear

cloudy

rain

snow

CLEANING AND CARE

Switch the unit off before cleaning by removing the batteries from the battery compartment of the main unit and the remote sensor. If the unit is powered by the adapter, unplug the power adapter.

Use a soft cloth to clean the unit.

Do not use liquid or aerosol detergents to clean the unit.

STORAGE

Unplug and clean the unit before taking it away for storage.

Wind the wired temperature sensor (22). Do not wind the sensor wire around the unit.

Keep the unit away from children in a dry cool place.

DELIVERY SET

Weather station main unit – 1 pc. Remote sensor – 1 pc.

Power adapter – 1 pcs. «AAA» batteries – 2 pcs. Instruction manual – 1 pc.

TECHNICAL SPECIFICATIONS

Measurements

Main unit

From 0 °С to + 50 °С

Remote sensor

From -40°С to +60°С

Temperature measuring

0,1 °С

precision

 

Relative humidity

from 20% to 90%

measuring:

 

Relative humidity

1%

measuring precision

 

Remote sensor data transmission

Data transmission

433 MHz

frequency

 

Number of sensors

3

Transmission range

Maximum 30m

Power supply

 

 

3 «ААА» type batteries 1,5 V or power

Main unit

adapter

input voltage: 220-240 V ~ 50 Hz

 

 

output voltage: direct current (DC) 3 V

Remote sensor

2 «ААА» type batteries 1,5 V

The manufacturer preserves the right to change the specifications of the unit without a preliminary notification.

Device operating life is 3 years

Guarantee

Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee.

This product conforms to the EMC-Requirements as laid down by the Council Directive 2004/108/ЕС and to the Low Voltage Regulation (2006/95/ЕС)

3

VT-3538.indd 1

27.06.2014 10:04:34

Loading...