Texas Instruments UA9637ACPS, UA9637ACP, UA9637ACDR, UA9637ACJG, UA9637ACD Datasheet

0 (0)

uA9637AC DUAL DIFFERENTIAL LINE RECEIVER

SLLS111B ± SEPTEMBER 1980 ± REVISED MAY 1995

D Meets or Exceeds the Requirements of

uA9637AC . . . D OR P PACKAGE

ANSI Standards EIA/TIA-422-B and

 

 

 

(TOP VIEW)

 

EIA/TIA-423-B and ITU Recommendations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V.10 and V.11

VCC

 

 

1

8

 

1IN+

 

 

 

D Operates From Single 5-V Power Supply

1OUT

 

 

2

7

 

1IN ±

D Wide Common-Mode Voltage Range

2OUT

 

 

3

6

 

2IN+

D High Input Impedance

GND

 

4

5

 

2IN ±

 

 

 

 

 

 

 

D TTL-Compatible Outputs

 

 

 

 

 

 

 

D High-Speed Schottky Circuitry

 

 

 

 

 

 

 

D 8-Pin Dual-in-Line and Small-Outline

 

 

 

 

 

 

 

Packages

 

 

 

 

 

 

 

D Designed to Be Interchangeable With

 

 

 

 

 

 

 

National DS9637A

 

 

 

 

 

 

 

description

The uA9637AC is a dual differential line receiver designed to meet ANSI Standards EIA/TIA-422-B and EIA/TIA-423-B and ITU Recommendations V.10 and V.11. The line receiver utilizes Schottky circuitry and has TTL-compatible outputs. The inputs are compatible with either a single-ended or a differential-line system. This device operates from a single 5-V power supply and is supplied in an 8-pin dual-in-line package or small-outline package.

The uA9637AC is characterized for operation from 0°C to 70°C.

logic symbol²

 

 

 

 

 

 

logic diagram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

1IN +

 

 

2

1OUT

1IN +

 

 

 

 

 

 

2

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

1OUT

1IN ±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1IN ±

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

2IN +

 

 

3

2OUT

 

 

 

 

 

 

 

2IN +

 

 

 

 

 

3

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

2OUT

2IN ±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2IN ±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

²This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.

Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.

PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.

Copyright 1995, Texas Instruments Incorporated

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

1

Texas Instruments UA9637ACPS, UA9637ACP, UA9637ACDR, UA9637ACJG, UA9637ACD Datasheet

uA9637AC

DUAL DIFFERENTIAL LINE RECEIVER

SLLS111B ± SEPTEMBER 1980 ± REVISED MAY 1995

EQUIVALENT OF EACH INPUT

TYPICAL OF ALL OUTPUTS

VCC

VCC

 

 

50 Ω NOM

8 kΩ

 

 

Output

Current

 

Source

 

schematics of inputs and outputs

 

Input

 

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)²

Supply voltage range, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . ±0.5 V to 7

V

Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . ± 15

V

Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . ± 15

V

Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . ±0.5 V to 5.5

V

Low-level output current, IOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . 50 mA

Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

See Dissipation Rating Table

Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . 0°C to 70°C

Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . ±65°C to 150°C

Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . 260°C

² Stresses beyond those listed under ªabsolute maximum ratingsº may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under ªrecommended operating conditionsº is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

NOTES: 1. All voltage values, except differential input voltage, are with respect to the network ground terminal.

2. Differential input voltage is measured at the noninverting input with respect to the corresponding inverting input.

DISSIPATION RATING TABLE

PACKAGE

TA 25°C

OPERATING FACTOR

TA = 70°C

TA = 125°C

POWER RATING

ABOVE TA = 25°C

POWER RATING

POWER RATING

 

D

725 mW

5.8 mW/°C

464 mW

Ð

P

1000 mW

8.0 mW/°C

640 mW

Ð

 

 

 

 

 

2

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

uA9637AC DUAL DIFFERENTIAL LINE RECEIVER

SLLS111B ± SEPTEMBER 1980 ± REVISED MAY 1995

recommended operating conditions

 

MIN

NOM

MAX

UNIT

 

 

 

 

 

Supply voltage, VCC

4.75

5

5.25

V

Common-mode input voltage, VIC

 

 

± 7

V

Operating free-air temperature, TA

0

 

70

°C

electrical characteristics over recommended ranges of supply voltage, common-mode input voltage, and operating free-air temperature (unless otherwise noted)

 

PARAMETER

TEST CONDITIONS

MIN

TYP²

MAX

UNIT

VIT +

Positive-going input threshold voltage

See Note 3

 

 

 

0.2

V

 

 

 

 

 

 

 

0.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIT ±

Negative-going input threshold voltage

See Note 3

 

± 0.2

 

 

V

 

 

 

 

 

±0.4³

 

 

 

 

 

 

 

 

 

Vhys

Hysteresis voltage (VIT+ ± VIT±)

 

 

 

70

 

mV

VOH

High-level output voltage

VID = 0.2 V,

IO = ± 1 mA

2.5

3.5

 

V

VOL

Low-level output voltage

VID = ± 0.2 V,

IO = 20 mA

 

0.35

0.5

V

 

 

V = 0 to 5.5 V,

VI = 10 V

 

1.1

3.25

 

II

Input current

CC

 

 

 

 

mA

See Note 4

VI = ± 10 V

 

± 1.6

± 3.25

 

 

 

 

I

Short-circuit output current§

V = 0,

V = 0.2 V

± 40

± 75

± 100

mA

OS

 

O

ID

 

 

 

 

ICC

Supply current

VID = ± 0.5 V,

No load

 

35

50

mA

²All typical values are at VCC = 5 V, TA = 25°C.

³The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold levels

only.

§ Only one output should be shorted at a time, and duration of the short circuit should not exceed one second. NOTES: 3. The expanded threshold parameter is tested with a 500-Ω resistor in series with each input.

4. The input not under test is grounded.

switching characteristics, VCC = 5 V, TA = 25°C

 

PARAMETER

TEST CONDITIONS

MIN TYP

MAX

UNIT

 

 

 

 

 

 

tPLH

Propagation delay time, lowto high-level output

CL = 30 pF, See Figure 1

15

25

ns

tPHL

Propagation delay time, highto low-level output

13

25

ns

 

POST OFFICE BOX 655303 DALLAS, TEXAS 75265