Texas Instruments uA 7906 C, uA 7908 C INSTALLATION INSTRUCTIONS

0 (0)

 

 

 

 

 

 

 

 

 

 

 

 

 

μA7900 SERIES

 

 

 

NEGATIVE-VOLTAGE REGULATORS

 

 

 

 

 

SLVS058A ± JUNE 1976 ± REVISED OCTOBER 1996

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

3-Terminal Regulators

 

 

KC PACKAGE

 

D Output Current Up to 1.5 A

 

 

(TOP VIEW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

No External Components

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

D Internal Thermal Overload Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

D

High-Power Dissipation Capability

 

 

 

 

 

 

 

 

 

 

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D Internal Short-Circuit Current Limiting

The input terminal is in electrical

 

D Output Transistor Safe-Area Compensation

contact with the mounting base

 

D Essentially Equivalent to National LM320

 

 

TO±220AB

 

 

Series

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

description

 

 

 

 

 

 

 

 

 

 

C

 

 

This series of fixed-negative-voltage monolithic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

integrated-circuit voltage regulators is designed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to complement Series μA7800 in a wide range of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

applications. These applications include on-card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

regulation for elimination of noise and distribution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

problems associated with single-point regulation.

 

 

KTE PACKAGE

 

 

Each of these regulators can deliver up to 1.5 A of

 

 

 

 

 

 

(TOP VIEW)

 

 

output current. The internal current limiting and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thermal shutdown features of these regulators

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

make them essentially immune to overload. In

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

addition to use as fixed-voltage regulators, these

 

 

 

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

devices can be used with external components to

 

 

 

 

 

 

 

 

 

 

COMMON

 

 

obtain adjustable output voltages and currents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.DataSheet4U.com

and also as the power pass element in precision

 

 

 

 

 

 

 

 

 

 

 

 

The input terminal is in electrical con-

 

 

regulators.

 

 

 

tact with the mounting base.

O I

C

AVAILABLE OPTIONS

 

VO(nom)

PACKAGED DEVICES

CHIP

TA

HEAT-SINK MOUNTED

HEAT-SINK MOUNTED²

FORM

(V)

 

(KC)

(KTE)

(Y)

 

 

 

 

 

 

 

 

± 5

μA7905CKC

μA7905CKTE

μA7905Y

 

± 5.2

μA7952CKC

μA7952CKTE

μA7952Y

 

± 6

μA7906CKC

μA7906CKTE

μA7906Y

0°C to 125°C

± 8

μA7908CKC

μA7908CKTE

μA7908Y

±12

μA7912CKC

μA7912CKTE

μA7912Y

 

 

±15

μA7915CKC

μA7915CKTE

μA7915Y

 

±18

μA7918CKC

μA7918CKTE

μA7918Y

 

± 24

μA7924CKC

μA7924CKTE

μA7924Y

² The KTE package is also available taped and reeled.

Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.

PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.

Copyright 1996, Texas Instruments Incorporated

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

1

Texas Instruments uA 7906 C, uA 7908 C INSTALLATION INSTRUCTIONS

μA7900 SERIES

NEGATIVE-VOLTAGE REGULATORS

SLVS058A ± JUNE 1976 ± REVISED OCTOBER 1996

schematic

5 V to 8 V

12 V to 18 V

COMMON

5 kΩ

OUTPUT

6.2

V

20 kΩ

0.2 kΩ

 

INPUT

 

INPUT

 

All component values are nominal.

absolute maximum ratings over operating temperature range (unless otherwise noted)

www.DataSheet4U.com

Input voltage, VI: μA7924C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . ±40 V

All others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . ±35 V

Continuous total power dissipation at (or below): TA = 25°C (see Note 1) . . .

See Dissipation Rating Tables

TC = 90°C (see Note 1) . . .

See Dissipation Rating Tables

Operating free-air, TA, case, TC, or virtual junction, TJ, temperature range . . .

. . . . . . . . . . . . . . . . 0 to 150°C

Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . ±65 to 150°C

Lead temperature 3.2 mm (1/8 inch) from case for 10 seconds . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . 260°C

NOTE 1: For operation above 25°C free-air or 90°C case temperature, refer to Figures 1 and 2. To avoid exceeding the design maximum virtual junction temperature, these ratings should not be exceeded. Due to variations in individual device electrical characteristics and thermal resistance, the built-in thermal overload protection may be activated at power levels slightly above or below the rated dissipation.

DISSIPATION RATING TABLE Ð FREE-AIR TEMPERATURE

 

PACKAGE

TA 25°C

DERATING FACTOR

TA = 70°C

TA = 105°C

 

TA = 125°C

 

 

POWER RATING

ABOVE TA = 25°C

 

POWER RATING

POWER RATING

POWER RATING

 

 

 

 

 

 

KC

2000 mW

16.0 mW/°C

 

1280 mW

720 mW

 

400 mW

 

 

 

 

 

 

 

 

 

 

 

 

KTE

1900 mW

15.2 mW/°C

 

1216 mW

684 mW

 

380 mW

 

 

 

DISSIPATION RATING TABLE Ð CASE TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PACKAGE

TC 90°C

DERATING FACTOR

TA = 125°C

 

 

 

 

 

POWER RATING

 

ABOVE TC = 90°C

POWER RATING

 

 

 

 

 

 

 

 

 

 

 

 

KC

15000 mW

 

250.0 mW/°C

6250 mW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KTE

14300 mW

 

238.0 mW/°C

5970 mW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

μA7900 SERIES

NEGATIVE-VOLTAGE REGULATORS

SLVS058A ± JUNE 1976 ± REVISED OCTOBER 1996

Maximum Continuous Dissipation ± mW

FREE-AIR TEMPERATURE

CASE TEMPERATURE

DISSIPATATION DERATING CURVE

DISSIPATION DERATING CURVE

2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

Derating factor = 16 mW/°C

 

 

 

 

 

 

 

 

 

200

 

RθJA 62.5°C/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

50

75

100

125

150

TA ± Free-Air Temperature ± °C

 

16

 

 

 

 

 

W

14

 

 

 

 

 

±

 

 

 

 

 

 

Dissipation

12

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

Continuous

8

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

Maximum

4

 

 

 

 

 

2

Derating factor = 0.25 W/°C

 

 

above 90°C

 

 

 

 

 

 

 

 

 

 

 

RθJA 4°C/W

 

 

 

 

 

0

 

 

 

 

 

 

25

50

75

100

125

150

 

 

TC ± Case Temperature ± °C

 

Figure 1 Figure 2

recommended operating conditions

www.DataSheet4U.com

 

 

MIN

MAX

UNIT

 

 

 

 

 

 

μA7905C

± 7

± 25

 

 

 

 

 

 

 

 

 

 

 

 

μA7952C

± 7.2

± 25

 

 

 

 

 

 

 

 

 

μA7906C

± 8

± 25

 

 

 

 

 

 

 

 

Input voltage, VI

μA7908C

± 10.5

± 25

V

 

 

 

 

 

μA7912C

± 14.5

± 30

 

 

 

 

 

 

 

 

 

 

 

μA7915C

± 17.5

± 30

 

 

 

 

 

 

 

 

 

μA7918C

± 21

± 33

 

 

 

 

 

 

 

 

 

μA7924C

± 27

± 28

 

 

 

 

 

 

 

 

Output current, IO

 

 

1.5

A

 

Operating virtual junction temperature, TJ

 

0

125

°C

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

3

Loading...
+ 7 hidden pages