NSC 5962-9218101MDA, 5962-9218101MCA, 5962-9218101M2A, 54ACTQ02MDA Datasheet

0 (0)
NSC 5962-9218101MDA, 5962-9218101MCA, 5962-9218101M2A, 54ACTQ02MDA Datasheet

September 1998

54ACTQ02

Quad 2-Input NOR Gate

General Description

The 'ACTQ02 contains four, 2-input NOR gates.

The 'ACTQ utilize NSC Quiet Series technology to guarantee quiet output switching and improved dynamic threshold performance. FACT Quiet Series® features GTO® output control and undershoot corrector in addition to a split ground bus for superior ACMOS performance.

nGuaranteed simultaneous switching noise level and dynamic threshold performance

nImproved latch-up immunity

nMinimum 4 kV ESD protection

nOutputs source/sink 24 mA

n'ACTQ02 has TTL-compatible inputs

nStandard Microcircuit Drawing (SMD) 5962-9218101

Features

n ICC reduced by 50%

Logic Symbol

Connection Diagrams

IEEE/IEC

Pin Assignment

 

for DIP and Flatpak

DS010889-1 DS010889-2

 

 

Pin Names

Description

Pin Assignment

 

 

 

 

 

An, Bn

Inputs

for LCC

 

Outputs

 

 

O

n

 

DS010889-3

GTOis a trademark of National Semiconductor Corporation.

FACTand FACT Quiet Seriesare trademarks of Fairchild Semiconductor Corporation.

Gate NOR Input-2 Quad 54ACTQ02

© 1998 National Semiconductor Corporation

DS010889

www.national.com

Absolute Maximum Ratings (Note 1)

If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications.

Supply Voltage (VCC)

−0.5V to +7.0V

DC Input Diode Current (IIK)

 

VI = −0.5V

−20 mA

VI = VCC + 0.5V

+20 mA

DC Input Voltage (VI)

−0.5V to V CC + 0.5V

DC Output Diode Current (IOK)

 

VO = −0.5V

−20 mA

VO = VCC + 0.5V

+20 mA

DC Output Voltage (VO)

−0.5V to V CC + 0.5V

DC Output Source

 

or Sink Current (IO)

±50 mA

DC VCC or Ground Current

 

per Output Pin (ICC or IGND)

±50 mA

Storage Temperature (TSTG)

−65ÊC to +150ÊC

DC Latch-Up Source or

±300 mA

Sink Current

Junction Temperature (TJ)

 

CDIP

175ÊC

Recommended Operating

Conditions

Supply Voltage (VCC)

 

'ACTQ

4.5V to 5.5V

Input Voltage (VI)

0V to VCC

Output Voltage (VO)

0V to VCC

Operating Temperature (TA)

 

54ACTQ

−55ÊC to +125ÊC

Minimum Input Edge Rate ( V/

t)

'ACTQ Devices

 

VIN from 0.8V to 2.0V

 

VCC @ 4.5V, 5.5V

125 mV/ns

Note 1: Absolute maximum ratings are those values beyond which damage to the device may occur. The databook specifications should be met, without exception, to ensure that the system design is reliable over its power supply, temperature, and output/input loading variables. National does not recommend operation of FACTcircuits outside databook specifications.

DC Characteristics for 'ACTQ Family Devices

 

 

 

54ACTQ

 

 

 

 

 

 

 

 

Symbol

Parameter

VCC

TA =

Units

Conditions

 

 

(V)

−55ÊC to +125ÊC

 

 

 

 

 

Guaranteed Limits

 

 

 

 

 

 

 

 

VIH

Minimum High Level

4.5

2.0

V

VOUT = 0.1V

 

Input Voltage

5.5

2.0

 

or VCC − 0.1V

VIL

Maximum Low Level

4.5

0.8

V

VOUT = 0.1V

 

Input Voltage

5.5

0.8

 

or VCC − 0.1V

VOH

Minimum High Level

4.5

4.4

V

IOUT = −50 µA

 

Output Voltage

5.5

5.4

 

 

 

 

 

 

 

 

 

 

 

 

 

VIN = VIL or VIH

 

 

4.5

3.70

V

IOH = −24 mA

 

 

5.5

4.70

 

IOH = −24 mA

VOL

Maximum Low Level

4.5

0.1

V

IOUT = 50 µA

 

Output Voltage

5.5

0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

VIN = VIL or VIH

 

 

4.5

0.50

V

IOL = 24 mA

 

 

5.5

0.50

 

IOL = 24 mA

IIN

Maximum Input

5.5

±1.0

µA

VI = VCC, GND

 

Leakage Current

 

 

 

 

 

 

 

 

 

 

ICCT

Maximum ICC/Input

5.5

1.6

mA

VI = VCC − 2.1V

IOLD

Minimum Dynamic

5.5

50

mA

VOLD = 1.65V Max

IOHD

Output Current (Note 2)

5.5

−50

mA

V OHD = 3.85V Min

ICC

Maximum Quiescent

5.5

40.0

µA

VIN = VCC or GND

 

Supply Current

 

 

 

(Note 3)

 

 

 

 

 

 

VOLP

Quiet Output

5.0

1.5

V

 

 

Maximum Dynamic VOL

 

 

 

(Note 4)

VOLV

Quiet Output

5.0

-1.2

V

 

 

Minimum Dynamic VOL

 

 

 

(Note 4)

Note 2: Maximum test duration 2.0 ms, one output loaded at a time.

Note 3: ICC for 54ACTQ @ 25ÊC is identical to 74ACTQ @ 25ÊC.

Note 4: Max number of outputs defined as (n). Data inputs are 0V to 3V. One output @ GND.

www.national.com

2

Loading...
+ 3 hidden pages