D-link DGS-1210-10P, DGS-1210-10, DGS-1210-52P, DGS-1210-52, DGS-1210-28P User Manual [ru]

...
0 (0)

WEB UI REFERENCE GUIDE

PRODUCT MODEL : DGS-1210/ME SERIES

METRO ETHERNET SWITCHES

RELEASE 1.10

©COPYRIGHT 2014. ALL RIGHTS RESERVED.

Table of Contents

DGS-1210 series Metro Ethernet Managed Switch User Manual

Table of Contents

 

 

Table of Contents .............................................................................................................................................

 

i

About This Guide.............................................................................................................................................

 

1

Terms/Usage..................................................................................................................................................

 

1

Copyright and Trademarks ............................................................................................................................

 

1

1 Product Introduction ...................................................................................................................................

 

2

Switch Description..........................................................................................................................................

 

2

Front Panel Description..................................................................................................................................

 

2

LED Indicators................................................................................................................................................

 

4

Rear Panel Description ..................................................................................................................................

 

5

Side Panel Description...................................................................................................................................

 

6

Gigabit Fiber Ports .........................................................................................................................................

 

6

Connecting the DPS-200 to the RPS Port (for DGS-1210-10/ME only) ........................................................

7

Installing the RPS into a Rack-mount Chassis (for DGS-1210-10/ME only) .................................................

7

DPS-800 Rack-mount Chassis...................................................................................................................

 

8

2 Hardware Installation ..................................................................................................................................

 

9

Step 1: Unpacking..........................................................................................................................................

 

9

Step 2: Switch Installation ..............................................................................................................................

 

9

Desktop or Shelf Installation.......................................................................................................................

 

9

Rack Installation .........................................................................................................................................

 

9

Step 3 – Plugging in the AC Power Cord.....................................................................................................

 

10

Power Failure ...........................................................................................................................................

 

11

3 Getting Started.............................................................................................................................................

 

6

Management Options.....................................................................................................................................

 

6

Using Web-based Management ....................................................................................................................

 

6

Supported Web Browsers ..........................................................................................................................

 

6

Connecting to the Switch............................................................................................................................

 

6

Login Web-based Management .................................................................................................................

 

7

Web-based Management...............................................................................................................................

 

7

4 Configuration ...............................................................................................................................................

 

8

Web-based Management...............................................................................................................................

 

8

Tool Bar > Save Menu ...................................................................................................................................

 

9

Save Configuration .....................................................................................................................................

 

9

Save Log ....................................................................................................................................................

 

9

Tool Bar > Tool Menu ....................................................................................................................................

 

9

Reset System .............................................................................................................................................

 

9

Reboot Device ............................................................................................................................................

 

9

Configuration Backup & Restore ..............................................................................................................

 

10

Firmware Backup & Upgrade ...................................................................................................................

 

10

Tool Bar > Online Help.................................................................................................................................

 

11

Function Tree ...............................................................................................................................................

 

11

Device Information....................................................................................................................................

 

12

System > System Settings .......................................................................................................................

 

13

System > Firmware Information ...............................................................................................................

 

13

System > IPv6 System Settings ...............................................................................................................

 

14

System > IPv6 Route Settings..................................................................................................................

 

14

System > IPv6 Neighbor Settings ............................................................................................................

 

14

System > DHCP Auto Configuration ........................................................................................................

 

15

i

Table of Contents

DGS-1210 series Metro Ethernet Managed Switch User Manual

System > Port Configuration > Port Settings ...........................................................................................

 

15

System > Port Configuration > Port Description

......................................................................................

16

System > Port Configuration > Port Error Disabled .................................................................................

17

System > SNMP Settings > SNMP Global State .....................................................................................

17

System > SNMP Settings > SNMP User Table........................................................................................

 

17

System > SNMP Settings > SNMP Group Table .....................................................................................

18

System > SNMP Settings > SNMP View Table .......................................................................................

 

19

System > SNMP Settings > SNMP Community Table .............................................................................

19

System > SNMP Settings > SNMP Host Table ........................................................................................

 

19

System > SNMP Settings > SNMP Engine ID .........................................................................................

 

20

System > SNMP Settings > SNMP Trap Settings ....................................................................................

20

System > User Accounts ..........................................................................................................................

 

21

System > MAC Address Aging Time........................................................................................................

 

21

System > ARP Aging Time Settings.........................................................................................................

 

21

System > PPPoE Circuit ID Insertion Settings .........................................................................................

 

22

System > Web Settings ............................................................................................................................

 

22

System > Telnet Settings .........................................................................................................................

 

22

System > Password Encryption................................................................................................................

 

23

System > Ping Test ..................................................................................................................................

 

23

System > MAC Notification Settings ........................................................................................................

 

23

System > System Log Configuration > System Log Settings ..................................................................

24

System > System Log Configuration > System Log Server .....................................................................

24

System > Time Profile ..............................................................................................................................

 

24

System > Power Saving ...........................................................................................................................

 

25

System > IEEE802.3az EEE Settings ......................................................................................................

 

26

System > SMTP Service > SMTP Server Settings ..................................................................................

26

System > SMTP Service > SMTP Service ...............................................................................................

 

27

System > D-Link Discover Protocol Settings............................................................................................

 

27

Configuration > Jumbo Frame..................................................................................................................

 

28

Configuration > 802.1Q VLAN..................................................................................................................

 

28

Configuration > 802.1Q Management VLAN............................................................................................

 

30

Configuration > VLAN Status ...................................................................................................................

 

31

Configuration > MAC-based VLAN Settings ............................................................................................

 

31

Configuration > GVRP Settings................................................................................................................

 

31

Configuration > GVRP Timer Settings .....................................................................................................

 

32

Configuration > QinQ > QinQ Settings .....................................................................................................

 

33

Configuration > QinQ > VLAN Translation CVID Entry Settings ..............................................................

34

Configuration > 802.1v Protocol VLAN > 802.1v Protocol Group Settings ..............................................

34

Configuration > 802.1v Protocol VLAN > 802.1v Protocol VLAN Settings...............................................

35

Configuration > VLAN Trunk Settings ......................................................................................................

 

35

Configuration > Link Aggregation > Port Trunkings .................................................................................

35

Configuration > Link Aggregation > LACP Port Settings..........................................................................

36

Configuration > BPDU Protection Settings...............................................................................................

 

37

Configuration > IGMP Snooping > IGMP Snooping .................................................................................

38

Configuration > IGMP Snooping > IGMP Access Control Settings..........................................................

39

Configuration > IGMP Snooping > ISM VLAN Settings ...........................................................................

40

Configuration > IGMP Snooping > Host Table .........................................................................................

 

41

Configuration > IGMP Snooping > IP Multicast Profile Settings ..............................................................

41

Configuration > IGMP Snooping > Limited Multicast Range Settings......................................................

41

 

ii

 

Table of Contents

DGS-1210 series Metro Ethernet Managed Switch User Manual

Configuration > IGMP Snooping > Max Multicast Group Settings ...........................................................

42

Configuration > MLD Snooping > MLD Snooping Settings ......................................................................

42

Configuration > MLD Snooping > MLD Host Table ..................................................................................

43

Configuration > Port Mirroring ..................................................................................................................

 

43

Configuration > Loopback Detection ........................................................................................................

 

44

Configuration > SNTP Settings > Time Settings ......................................................................................

45

Configuration > SNTP Settings > TimeZone Settings ..............................................................................

45

Configuration > DHCP/BOOTP Relay > DHCP/BOOTP Relay Global Settings ......................................

46

Configuration > DHCP/BOOTP Relay > DHCP/BOOTP Relay Interface Settings ..................................

47

Configuration > DHCP Local Relay Settings............................................................................................

 

48

Configuration > DHCPv6 Relay Settings..................................................................................................

 

48

Configuration > Spanning Tree > STP Bridge Global Settings ................................................................

49

Configuration > Spanning Tree > STP Port Settings ...............................................................................

51

Configuration > Spanning Tree > MST Configuration Identification.........................................................

52

Configuration > Spanning Tree > STP Instance Settings ........................................................................

52

Configuration > Spanning Tree > MSTP Port Information .......................................................................

53

Configuration > Ethernet OAM > Ethernet OAM Port Settings ................................................................

53

Configuration > Ethernet OAM > Ethernet OAM Event Configuration .....................................................

54

Configuration > DULD > DULD Port Settings ..........................................................................................

 

55

Configuration > Multicast Forwarding & Filtering > Multicast Forwarding ................................................

55

Configuration > Multicast Forwarding & Filtering > Multicast Filtering .....................................................

56

QoS > Traffic Control................................................................................................................................

 

56

QoS > Bandwidth Control.........................................................................................................................

 

57

QoS > CoS Scheduling Mechanism .........................................................................................................

 

58

QoS > CoS Output Scheduling ................................................................................................................

 

58

QoS > 802.1p Default Priority...................................................................................................................

 

59

QoS > 802.1p User Priority ......................................................................................................................

 

59

QoS > DSCP Priority Settings ..................................................................................................................

 

59

QoS > Priority Settings .............................................................................................................................

 

60

RMON > RMON Basic Settings................................................................................................................

 

60

RMON > RMON Ethernet Statistics Configuration...................................................................................

61

RMON > RMON History Control Configuration ........................................................................................

 

61

RMON > RMON Alarm Configuration ......................................................................................................

 

61

RMON > RMON Event Configuration.......................................................................................................

 

62

Security > Trusted Host............................................................................................................................

 

63

Security > Safeguard Engine....................................................................................................................

 

63

Security > ARP Spoofing Prevention .......................................................................................................

 

63

Security > Gratuitous ARP .......................................................................................................................

 

64

Security > Port Security............................................................................................................................

 

65

Security > SSL Settings............................................................................................................................

 

65

Security > Smart Binding > Smart Binding Settings .................................................................................

66

Security > Smart Binding > Smart Binding ...............................................................................................

 

67

Security > Smart Binding > White List......................................................................................................

 

68

Security > Smart Binding > Black List ......................................................................................................

 

68

Security > Smart Binding > DHCP Snooping List ....................................................................................

69

Security > 802.1X > 802.1X Settings .......................................................................................................

 

69

Security > 802.1X > 802.1X User.............................................................................................................

 

71

Security > 802.1X > 802.1X Authentication RADIUS...............................................................................

71

Security > 802.1X > 802.1X Guest VLAN ................................................................................................

 

72

 

iii

 

Table of Contents

DGS - 1210 series Metro Ethernet Managed Switch User Manual

Security > MAC Address Table > Static MAC

..........................................................................................

72

Security > MAC Address Table > Dynamic Forwarding Table.................................................................

73

Security > Access Authentication Control > Authentication ............................................Policy Settings

74

Security > Access Authentication Control > Application ....................................Authentication Settings

74

Security > Access Authentication Control > Authentication ..............................................Server Group

74

Security > Access Authentication Control > Authentication .........................................................Server

75

Security > Access Authentication Control > Login ..............................................................Method Lists

76

Security > Access Authentication Control > Enable ...........................................................Method Lists

77

Security > Access Authentication Control > Local ........................................Enable Password Settings

77

Security > Traffic Segmentation ...............................................................................................................

 

78

Security > DoS Prevention Settings .........................................................................................................

 

78

Security > DHCP Server Screening > DHCP ........................................Server Screening Port Settings

79

Security > DHCP Server Screening > Filter DHCP ......................................................................Server

79

Security > SSH Settings > SSH Settings .................................................................................................

 

79

Security > SSH Settings > SSH Authmode and ........................................................Algorithm Settings

80

Security > SSH Settings > SSH User Authentication ......................................................................Lists

81

Security > MAC-based Access Control (MAC) ..........................> MAC-based Access Control Settings

82

Security > MAC-based Access Control (MAC) ................> MAC-based Access Control Local Settings

83

Security > MAC-based Access Control (MAC) ......> MAC-based Access Control Authentication State

83

Security > Web-based Access Control (WAC) ...................................................> WAC Global Settings

84

Security > Web-based Access Control (WAC) .....................................................> WAC User Settings

84

Security > Web-based Access Control (WAC) ......................................................> WAC Port Settings

85

Security > Web-based Access Control (WAC) ...........................................> WAC Authentication State

85

Monitoring > Statistics ..............................................................................................................................

 

86

Monitoring > Session Table......................................................................................................................

 

86

Monitoring > CPU Utilization ....................................................................................................................

 

87

Monitoring > Memory Utilization ...............................................................................................................

 

87

Monitoring > Port Utilization .....................................................................................................................

 

88

Monitoring > Packet Size..........................................................................................................................

 

89

Monitoring > Packets > Transmitted (TX) ................................................................................................

 

90

Monitoring > Packets > Received (RX) ....................................................................................................

 

91

Monitoring > Packets > UMB Cast (RX)...................................................................................................

 

93

Monitoring > Errors > Received (RX) .......................................................................................................

 

94

Monitoring > Errors > Transmitted (TX)....................................................................................................

 

95

Monitoring > Cable Diagnostics ...............................................................................................................

 

97

Monitoring > System Log..........................................................................................................................

 

98

Monitoring > Browse ARP Table ..............................................................................................................

 

98

Monitoring > Ethernet OAM > Browse Ethernet ............................................................OAM Event Log

98

Monitoring > Ethernet OAM > Browse Ethernet ..............................................................OAM Statistics

99

Monitoring > IGMP Snooping > IGMP Snooping ..........................................................................Group

99

Monitoring > IGMP Snooping > IGMP Snooping ...........................................................................Host

100

Monitoring > Port Access Control > RADIUS .................................................................Authentication

100

Monitoring > Port Access Control > RADIUS ................................................................Account Client

101

ACL > ACL Configuration Wizard...........................................................................................................

 

102

ACL > Access Profile List .......................................................................................................................

 

103

ACL > ACL Finder ..................................................................................................................................

 

104

ACL > CPU Filter Configuration Wizard .................................................................................................

 

105

ACL > CPU Filter Access Profile List .....................................................................................................

 

106

ACL > CPU Filter Finder.........................................................................................................................

 

107

 

iv

 

Table of Contents

DGS-1210 series Metro Ethernet Managed Switch User Manual

ACL > ACL Flow Meter...........................................................................................................................

 

107

PoE > PoE Port Settings (DGS-1210-28P/ME only) ..............................................................................

108

PoE > PoE System Settings (DGS-1210-28P/ME only) ........................................................................

110

Time-Based PoE > Time Range Settings ..............................................................................................

 

110

LLDP > LLDP Global Settings ................................................................................................................

 

111

LLDP > Basic LLDP Port Settings ..........................................................................................................

 

111

LLDP > 802.1 Extension LLDP Port Settings.........................................................................................

 

112

LLDP > 802.3 Extension LLDP Port Settings.........................................................................................

 

113

LLDP > LLDP Management Address Settings .......................................................................................

 

113

LLDP > LLDP Statistics Table ................................................................................................................

 

114

LLDP > LLDP Management Address Table ...........................................................................................

 

114

LLDP > LLDP Local Port Table ..............................................................................................................

 

115

LLDP > LLDP Remote Port Table ..........................................................................................................

 

116

LLDP > LLDP-MED Settings ..................................................................................................................

 

117

Appendix A - Ethernet Technology............................................................................................................

 

109

Gigabit Ethernet Technology .....................................................................................................................

 

109

Fast Ethernet Technology ..........................................................................................................................

 

109

Switching Technology ................................................................................................................................

 

109

Appendix B - Ethernet Technology............................................................................................................

 

110

Features .....................................................................................................................................................

 

110

L2 Features ............................................................................................................................................

 

110

VLAN ......................................................................................................................................................

 

110

L3 Features ............................................................................................................................................

 

110

QoS (Quality of Service).........................................................................................................................

 

110

Security...................................................................................................................................................

 

110

OAM .......................................................................................................................................................

 

111

Management...........................................................................................................................................

 

111

v

About This Guide

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

About This Guide

This guide provides instructions to install the D-Link DGS-1210/ME Metro Ethernet Switch and to configure with HTTP step-by-step.

Note: The model you have purchased may appear slightly different from the illustrations shown in the document. Refer to the Product Instruction and Technical Specification sections for detailed information about your switch, its components, network connections, and technical specifications.

This guide is mainly divided into three parts:

1.Hardware Installation: Step-by-step hardware installation procedures.

2.Getting Started: A startup guide for basic switch installation and settings.

3.Configuration: Information about the function descriptions and configuration settings.

Terms/Usage

In this guide, the term “Switch” (first letter capitalized) refers to DGS-1210/ME Metro Ethernet Switch, and “switch” (first letter lower case) refers to other Ethernet switches. Some technologies refer to terms “switch”, “bridge” and “switching hubs” interchangeably, and both are commonly accepted for Ethernet switches.

A NOTE indicates important information that helps a better use of the device.

A CAUTION indicates potential property damage or personal injury.

Copyright and Trademarks

Information in this document is subjected to change without notice. © 2014 D-Link Corporation. All rights reserved.

Reproduction in any manner whatsoever without the written permission of D-Link Corporation is strictly forbidden.

Trademarks used in this text: D-Link and the D-LINK logo are trademarks of D-Link Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. D-Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own.

1

1 Product Introduction

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

1 Product Introduction

Switch Description

Front Panel Description

LED Indicators

Rear Panel Description

Side Panel Description

Connecting the DPS-200 to the RPS Port (for DGS-1210-10/ME only)

Installing the RPS into the Rack-mount Chassis (for DGS-1210-10/ME only)

Switch Description

The DGS-1210/ME Metro Ethernet Switch is equipped with Copper ports (10/100/1000Mbps) and SFP ports (1000Mbps) that can be used to attach various networking devices to the network like Computers, Notebooks, Print Servers, Network Attached Storage devices, IP Cameras, VoIP PBX devices, and other Switches. The Small Form Factor Portable (SFP) ports can be used together with fiber-optical transceivers in order to connect various other networking devices, using a fiber-optic connection, to the network at Gigabit Ethernet speeds over great distances.

This DGS-1210/ME Metro Ethernet Switch provides unsurpassed performance, fault tolerance, scalability, robust security, standard-based interoperability and impressive technology to future-proof departmental and enterprise network deployments.

It allows IGMP Snooping and Authentication, QoS, Bandwidth Control, ACL and many security functions. It can be managed by Web UI, or commands via Telnet.

The DGS-1210/ME Metro Ethernet Switches have different port configuration (10/100/1000Base-T or SFP ports) that may be used in to uplink various network devices to the Switch, including PCs, hubs and other switches to provide a gigabit Ethernet uplink in full-duplex mode. The SFP (Small Form Factor Portable) ports are used with fiber-optical transceiver cabling in order to uplink various other networking devices for a gigabit link that may span great distances.

Front Panel Description

The front panel of the DGS-1210-10/ME switch consists out of the following:

8 10/100/1000Mbps Copper Ports

2 1000Mbps SFP port

One RJ-45 Console Port

LEDs for Power, Console, RPS, Link/Act for port 1 ~ 10.

Figure 1.1 – DGS-1210-10/ME Front Panel

CAUTION: The MiniGBIC ports should use UL listed

Optical Transceiver product, Rated Laser Class I. 3.3Vdc.

The front panel of the DGS-1210-20/ME switch consists out of the following:

16 10/100/1000Mbps Copper Ports

4 1000Mbps SFP port

One RJ-45 Console Port

LEDs for Power, Console, Link/Act for port 1 ~ 20.

1 Product Introduction

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 1.2 – DGS-1210-20/ME Front Panel

CAUTION: The MiniGBIC ports should use UL listed

Optical Transceiver product, Rated Laser Class I. 3.3Vdc.

The front panel of the DGS-1210-28/ME switch consists out of the following:

24 10/100/1000Mbps Copper Ports

4 1000Mbps SFP port

One RJ-45 Console Port

LEDs for Power, Console, Link/Act for port 1 ~ 28

Figure 1.3 – DGS-1210-28/ME Front Panel

CAUTION: The MiniGBIC ports should use UL listed

Optical Transceiver product, Rated Laser Class I. 3.3Vdc.

The front panel of the DGS-1210-52/ME switch consists out of the following:

48 10/100/1000Mbps Copper Ports

4 1000Mbps SFP port

LEDs for Power, Console, Fan Error , Link/Act for port 1 to 52

Figure 1.4 – DGS-1210-52/ME SERIES Front Panel

CAUTION: The MiniGBIC ports should use UL listed

Optical Transceiver product, Rated Laser Class I. 3.3Vdc.

The front panel of the DGS-1210-28P/ME switch consists out of the following:

24 10/100/1000Mbps Copper Ports

4 1000Mbps SFP port

One RJ-45 Console Port

LEDs for Power, Console, Fan Error, Pwr Max, Link/Act for port 1 to 28

Mode: By pressing the Mode button, the Port LED will switch between Link/Act and PoE modes.

3

1 Product Introduction

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 1.5 – DGS-1210-28P/ME Front Panel

CAUTION: The MiniGBIC ports should use UL listed

Optical Transceiver product, Rated Laser Class I. 3.3Vdc.

LED Indicators

The Switch supports LED indicators for Power, Console, Fan, and Link/Act for each port. The following shows the LED indicators for the DGS-1210/ME Metro Ethernet Switch along with an explanation of each indicator.

Figure 1.6 –LED Indicators on DGS-1210/ME SERIES

Location

 

LED Indicative

 

Color

 

Status

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Green

 

Solid Light

 

Power on.

 

 

 

 

 

 

 

 

 

 

 

 

 

Light off

 

Power off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid Light

 

Console on.

 

 

 

Console

 

 

 

 

 

 

 

 

 

 

Green

 

Blinking

 

POST is in progress.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Light off

 

Console off.

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Error

 

Red

 

Solid light

 

The fan has runtime failure and is

 

 

 

 

 

 

brought offline.

 

Per Device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Pwr Max LED lights up when the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch reaches the maximum power

 

 

 

Pwr Max.

 

Red

 

Solid light

 

budget defined by the administrator

 

 

 

 

 

 

via PoE System Settings page of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Web GUI or the default power budget

 

 

 

 

 

 

 

 

 

of 78 Watts.

 

 

 

RPS

 

 

 

Solid Light

 

RPS power on.

 

 

 

(DGS-1210-10/ME

 

Green

 

 

 

 

 

 

 

 

 

Light off

 

RPS power off.

 

 

 

only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solid Green

 

When there is a secure 1000Mbps

 

 

 

 

 

 

 

 

 

Ethernet connection (or link) at any

 

 

 

 

 

 

 

 

 

of the ports.

 

 

 

 

 

 

 

Blinking Green

 

When there is reception or

 

 

 

 

 

 

 

 

 

transmission (i.e. Activity—Act) of

 

 

 

 

 

 

 

 

 

data occurring at a 1000Mbps

 

LED Per

 

 

 

 

 

 

 

Ethernet connected port.

 

 

Link/Act

 

Green/Amber

 

Solid Amber

 

When there is a secure 10/100Mbps

 

10/100/1000Mbps

 

 

 

 

 

Copper Port

 

 

 

 

 

 

 

Ethernet connection (or link) at any

 

 

 

 

 

 

 

 

of the ports.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking Amber

 

When there is reception or

 

 

 

 

 

 

 

 

 

transmission (i.e. Activity—Act) of

 

 

 

 

 

 

 

 

 

data occurring at a 10/100Mbps

 

 

 

 

 

 

 

 

 

Ethernet connected port.

 

 

 

 

 

 

 

Light off

 

No link.

 

 

 

PoE Mode

 

Green

 

Solid Light

 

Power feeding

 

1 Product Introduction

 

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amber

 

Solid Light

Error Condition

 

 

Off

 

Solid Off

No Power feeding

 

 

 

 

 

When there is a secure 1000Mbps

 

 

 

 

Solid Green

Ethernet connection (or link) at any

LED Per

 

 

 

 

of the ports.

 

 

 

 

When there is reception or

1000Mbps SFP

Link/Act

Green

 

 

 

 

transmission (i.e. Activity—Act) of

Port

 

 

 

Blinking Green

 

 

 

 

 

data occurring at a 1000Mbps

 

 

 

 

 

Ethernet connected port.

 

 

 

 

Light off

No link.

Rear Panel Description

The rear panel of the Switch contains an AC power connector. The AC power connector is a standard threepronged connector that supports the power cord. Plug-in the female connector of the provided power cord into this socket, and the male side of the cord into a power outlet. The Switch automatically adjusts its power setting to any supply voltage in the range from 100 to 240 VAC at 50 to 60 Hz. Connect the Kensingtoncompatible security lock, at the rear of the switch, to a secure immovable device. Insert the lock into the notch and turn the key to secure the lock.

The rear panel also includes an outlet for an optional external power supply and one RJ-45 console port. When a power failure occurs, the optional external RPS will immediately and automatically assume the power supply for the Switch.

DGS-1210-10/ME

Figure 1.7 DGS-1210-10/ME rear panel

DGS-1210-20/ME

Figure 1.8 DGS-1210-20/ME rear panel

DGS-1210-28/ME

Figure 1.9 DGS-1210-28/ME real panel

DGS-1210-28P/ME

Figure 1.10 DGS-1210-28P/ME real panel

5

1 Product Introduction

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

DGS-1210-52/ME

Figure 1.11 DGS-1210-52/ME real panel

Side Panel Description

The leftand right-hand panels of the Switch have heat vents to dissipate heat. Do not block these openings, and leave at least 6 inches of space at the rear and sides of the Switch for proper ventilation. Be reminded that without proper heat dissipation and air circulation, system components might overheat, which could lead to system failure.

Figure 1.12 - Side panels of the DGS-1210/ME SERIES

Gigabit Fiber Ports

The DGS-1210/ME Series features support four Small Form Factor Portable (SFP) ports (optional). See the diagram below to view the four SFP port modules being plugged into the Switch.

Figure 1.13 - Inserting the SFP modules into the Switch

1 Product Introduction

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 1.14 - Installing the SFP Module

The Switch is equipped with SFP ports, which are to be used with fiber-optical transceiver cabling in order to uplink various other networking devices for a gigabit link that may span great distances.

Connecting the DPS-200 to the RPS Port (for DGS-1210-10/ME only)

The DPS-200 redundant power supply can be connected to the RPS port of the Switch using the DC power supply cord, called the DPS-CB150-2PS. It is important to notice that the DPS-200 can supply power to one or two DGS-1210-10/ME at the same time.

Figure 1.15 – Connecting two Switches to the DPS-200

The following section explains how to connect the DPS-200 to the Switch.

Disconnect the Switch from the main AC power source.

Insert the 14-pin end of the DPS-CB150-2PS into the DPS-200 and the 2-pin end into the receptacle of the RPS port on the Switch.

Using a standard AC power cord, connect the DPS-200 to the main AC power source. A green LED on the front panel of the DPS-200 will illuminate to indicate a successful connection.

Make sure that the ON/OFF toggle switch on the rear panel of the Switch is turned on.

Re-connect the Switch to the AC power source and power on the DPS-200.

No configuration is needed in the Switch software for this installation.

NOTE: See the DPS-200 Quick Installation Guide for more information.

Installing the RPS into a Rack-mount Chassis (for DGS-1210-10/ME only)

7

1 Product Introduction

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

The DPS-200 is the redundant power supply unit designed to conform to the voltage requirements of the RPS port of the Switch being supported. The DPS-200 can be installed into a DPS-800 and a DPS-900 rackmount chassis unit.

CAUTION: DO NOT connect the RPS to the AC power before the DC power cable is connected. Connecting the AC power before the DC power is connected might damage the internal power supply.

DPS-800 Rack-mount Chassis

The DPS-800 is a standard-size rack-mount (1 standard unit in height) designed to hold up to two DPS-200 redundant power supplies.

Figure 1.16 –Installing the DPS-200 in the DPS-800

The DPS-800 rack-mount chassis can be mounted into a standard 19" rack. Use the following diagram to guide you.

2 Hardware Installation

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

2 Hardware Installation

This chapter provides unpacking and installation information for the D-Link DGS-1210/ME Metro Ethernet Switch.

Step 1: Unpacking

Open the shipping carton and carefully unpack its contents. Please consult the packing list located in the User Manual to make sure all items are present and undamaged. If any item is missing or damaged, please contact your local D-Link reseller for replacement.

One D-Link Metro Ethernet Switch

One multi-language Getting Started Guide

One CD

One RJ-45 console cable

Power cord clip

Power cord

Rack mount kit

Rubber feet

If any item is found missing or damaged, please contact the local reseller for replacement.

Step 2: Switch Installation

For safe switch installation and operation, it is recommended that you:

Visually inspect the power cord to see that it is secured fully to the AC power connector. Make sure that there is proper heat dissipation and adequate ventilation around the switch. Do not place heavy objects on the switch.

Desktop or Shelf Installation

When installing the switch on a desktop or shelf, the rubber feet included with the device must be attached on the bottom at each corner of the device’s base. Allow enough ventilation space between the device and the objects around it.

Figure 2.1 – Attach the adhesive rubber pads to the bottom

Rack Installation

The switch can be mounted in an EIA standard size 19-inch rack, which can be placed in a wiring closet with other equipment. To install, attach the mounting brackets to the switch’s side panels (one on each side) and secure them with the screws provided (please note that these brackets are not designed for palm size switches).

Figure 2.2 – Attach the mounting brackets to the Switch

9

2 Hardware Installation

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Then, use the screws provided with the equipment rack to mount the switch in the rack.

Figure 2.3 – Mount the Switch in the rack or chassis

Please be aware of following safety Instructions when installing:

A)Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

B)Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

C)Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

D)Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit, and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E)Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."

Step 3 – Plugging in the AC Power Cord

Users may now connect the AC power cord into the rear of the switch and to an electrical outlet (preferably one that is grounded and surge protected).

2 Hardware Installation

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 2.5 – Plugging the switch into an outlet

Power Failure

As a precaution, the switch should be unplugged in case of power failure. When power is resumed, plug the switch back in.

11

3 Getting Started

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

3 Getting Started

This chapter introduces the management interface of D-Link DGS-1210/ME Metro Ethernet Switch.

Management Options

Using Web-based Management

Connecting to the Console Port

Management Options

The D-Link DGS-1210/ME Metro Ethernet Switch can be managed through any port on the device by using the Web-based Management, out-of band through the console port on the front/back panel and in-band using Telnet

Each switch must be assigned its own IP Address, which is used for communication with the Web-Based Management or a SNMP network manager. The PC should have an IP address in the same range as the switch. Each switch can allow up to four users to access the Web-Based Management concurrently.

Please refer to the following installation instructions for the Web-based Management.

Using Web-based Management

After a successful physical installation, you can configure the Switch, monitor the network status, and display statistics using a web browser.

Supported Web Browsers

The embedded Web-based Management currently supports the following web browsers:

Internet Explorer 6/7 or later version

Netscape 8 or later version

Mozilla

Firefox 1.5/2.0 or later version Chrome 5.0 or later version Safari 4.0 or later version

Connecting to the Switch

You will need the following equipment to begin the web configuration of your device:

1.A PC with a RJ-45 Ethernet connection

2.A standard Ethernet cable

Connect the Ethernet cable to any of the ports on the front panel of the switch and to the Ethernet port on the PC.

Figure 3.1 – Connected Ethernet cable

6

3 Getting Started

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Login Web-based Management

In order to login and configure the switch via an Ethernet connection, the PC must have an IP address in the same subnet as the switch. For example, if the switch has an IP address of 10.90.90.90, the PC should have an IP address of 10.x.y.z (where x/y is a number between 0 ~ 254 and z is a number between 1 ~ 254), and a subnet mask of 255.0.0.0. Enter 10.90.90.90 (the factory default IP address) in the address bar of your web browser and press <Enter>.

Figure 3.2 –Enter the IP address 10.90.90.90 in the web browser

NOTE: The switch's factory default IP address is 10.90.90.90 with a subnet mask of 255.0.0.0 and a default gateway of 0.0.0.0.

When the following logon dialog box appears, enter the password and choose the language of the Webbased Management interface then click OK.

By default, the Username and Password are empty.

Figure 3.3 – Logon Dialog Box

Web-based Management

By clicking the OK button in Logon Dialog Box, you will enter the Web-based Management interface. Please refer to Chapter 4 Configuration for detailed instructions.

7

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

4 Configuration

The features and functions of the D-Link DGS-1210/ME Metro Ethernet Switch can be configured for optimum use through the Web-based user interface.

Web-based Management

After press the OK button in Logon Dialog Box, you will see the screen below:

Figure 4.1 – Web-based Management

The above image is the Web-based Management screen. The three main areas are the Tool Bar on top, the

Function Tree, and the Main Configuration Screen.

The Tool Bar provides a quick and convenient way for essential utility functions like firmware and configuration management.

By choosing different functions in the Function Tree, you can change all the settings in the Main Configuration Screen. The main configuration screen will show the current status of your Switch by clicking the model name on top of the function tree.

At the upper right corner of the screen the username and current IP address will be displayed.

Under the username is the Logout button. Click this to end this session.

NOTE: If you close the web browser without clicking the Logout button first, then it will be seen as an abnormal exit and the login session will still be occupied.

8

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Finally, by clicking on the D-Link logo at the upper-left corner of the screen you will be redirected to the local D-Link website.

Tool Bar > Save Menu

The Save Menu provides Save Configuration and Save Log functions.

Figure 4.2 – Save Menu

Save Configuration

Select to save the entire configuration changes you have made to the device to switch’s non-volatile RAM.

Figure 4.3 – Save Configuration

Save Log

Save the log entries to your local drive and a pop-up message will prompt you for the file path. You can view or edit the log file by using text editor (e.g. Notepad).

Figure 4.4 – Save Log

Tool Bar > Tool Menu

The Tool Menu offers global function controls such as Reset, Reset System, Reboot Device, Configuration Backup and Restore, Firmware Backup and Upgrade.

Figure 4.5 – Tool Menu

Reset System

Provide another safe reset option for the Switch. All configuration settings in non-volatile RAM will reset to factory default and the Switch will reboot.

Figure 4.6 – Tool Menu > Reset System

Select the different reset method then click Apply to reset the system.

Reboot Device

Provide a safe way to reboot the system. Click Reboot to restart the switch.

9

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 4.7 – Tool Menu > Reboot Device

Configuration Backup & Restore

Allow the current configuration settings to be saved to a file (not including the password), and if necessary, you can restore configuration settings from this file. Two methods can be selected: HTTP or TFTP.

Figure 4.8 – Tool Menu > Configure Backup and Restore

HTTP: Backup or restore the configuration file to or from your local drive.

Click Backup to save the current settings to your disk.

Click Browse to browse your inventories for a saved backup settings file.

Click Restore after selecting the backup settings file you want to restore.

TFTP: TFTP (Trivial File Transfer Protocol) is a file transfer protocol that allows you to transfer files to a remote TFTP server. Specify TFTP Server IPv4 or IPv6 Address and TFTP File Name for the configuration file you want to save to / restore from. The maximum Telnet Server connection is 4.

Click Backup to save the current settings to the TFTP server.

Click Restore after selecting the backup settings file you want to restore.

Note: Switch will reboot after restore, and all current configurations will be lost.

Firmware Backup & Upgrade

Allow for the firmware to be saved, or for an existing firmware file to be uploaded to the Switch. Two methods can be selected: HTTP or TFTP.

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 4.9 – Tool Menu > Firmware Backup and Upgrade

HTTP: Backup or upgrade the firmware to or from your local PC drive. Click Backup to save the firmware to your disk.

Click Browse to browse your inventories for a saved firmware file. Click Upgrade after selecting the firmware file you want to restore.

TFTP: Backup or upgrade the firmware to or from a remote TFTP server. Specify TFTP Server IPv4 or IPv6 Address and File Name for the configuration file you want to save to / restore from. The maximum Telnet Server connection is 4.

Click Backup to save the firmware to the TFTP server.

Click Upgrade after selecting the firmware file you want to restore.

CAUTION: Do not disconnect the PC or remove the power cord from device until the upgrade completes. The Switch may crash if the Firmware upgrade is incomplete.

Tool Bar > Online Help

The Online Help provides two ways of online support:

Figure 4.10 – Online Help

D-Link Support Site: This will lead you to the D-Link website where you can find online resources such as updated firmware images.

User Guide: This can offer an immediate reference for the feature definition or configuration guide. Click Apply to make configuration effected.

Function Tree

All configuration options on the switch are accessed through the Setup menu on the left side of the screen. Click on the setup item that you want to configure. The following sections provide more detailed description of each feature and function.

11

D-link DGS-1210-10P, DGS-1210-10, DGS-1210-52P, DGS-1210-52, DGS-1210-28P User Manual

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 4.11 –Function Tree

Device Information

The Device Information provides an overview of the switch, including essential information such as firmware & hardware information, and IP address.

It also offers an overall status of common software features:

STP: Click Settings to link to Configuration > Spanning Tree > STP Bridge Global Settings. Default is disabled.

Port Mirroring: Click Settings to link to Configuration > Port Mirroring. Default is disabled.

IGMP Snooping: Click Settings to link to Configuration > IGMP Snooping > IGMP Snooping. Default is disabled.

Safeguard Engine: Click Settings to link to Security > Safeguard Engine. Default is enabled.

SNMP Status: Click Settings to link to System > SNMP Settings > SNMP Global State. Default is enabled. 802.1X Status: Click Settings to link to Security > 802.1X > 802.1X Settings. Default is disabled.

802.1Q Management VLAN: Click Settings to link to Configuration > 802.1Q Management VLAN. Default is disabled.

DHCP Client: Click Settings to link to System > System Settings. Default is disabled.

Figure 4.12 – Device Information

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

System > System Settings

The System Setting allows the user to configure the IP address and the basic system information of the Switch.

IP Information: There are two ways for the switch to obtain an IP address: Static and DHCP (Dynamic Host Configuration Protocol).

When using static mode, the IP Address, Subnet Mask, Gateway and DHCP Option 12 State can be manually configured. When using DHCP mode, the Switch will first look for a DHCP server to provide it with an IP address (including network mask and default gateway) before using the default or previously entered settings. By default the IP setting is static mode with IP address is 10.90.90.90 and subnet mask is 255.0.0.0.

System Information: By entering a System Name and System Location, the device can more easily be recognized.

Login Timeout: The Login Timeout controls the idle time-out period for security purposes, and when there is no action for a specific time span in the Web-based Management. If the current session times out (expires), the user is required a re-login before using the Web-based Management again. Selective range is from 3 to 30 minutes, and the default setting is 5 minutes.

Group Interval: The user can adjust the Group Interval to optimal frequency. Selective range is from 120 to 1225 seconds, and 0 means disabling the reporting function.

Figure 4.13 – System > System Settings

System > Firmware Information

The Serial Port Settings page displays the information of firmware.

.

Figure 4.14 – System > Firmware Information

13

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

System > IPv6 System Settings

The IPv6 System Settings page allow user to configure the IPv6 system information.

.

Figure 4.15 – System > IPv6 System Settings

IPv6 System Settings:

Interface Name: Displays the interface name of IPv6. IPv6 State: Specifies the IPv6 to be enabled or disabled.

DHCPv6 Client: Specifies the DHCPv6 client to be enabled or disabled. IPv6 Network Address: Specifies the IPv6 Network Address.

NS Retransmit Time Settings:

NS Retransmit Time (1-3600): Enter the Neighbor solicitation’s retransmit timer in second here. Specifies the NS retransmit time for IPv6. The field range is 1-3600, and default is 1 second.

Automatic Link Local State Settings:

Automatic Link Local Address: Specifies the automatic link is enabled or disabled.

Click Apply for the settings to take effect.

System > IPv6 Route Settings

The IPv6 Route Settings page allows user to configure the IPv6 route settings.

Figure 4.16 – System > IPv6 Route Settings

IP Interface: Specify the IP interface which to be created.

Default Gateway: The corresponding IPv6 address for the next hop Gateway address in IPv6 format..

Metric: Represents the metric value of the IP interface entered into the table. This field may read a number between 1 and 65535.

Click Create to accept the changes made, and click the Delete button to remove the entry.

System > IPv6 Neighbor Settings

The user can configure the Switch’s IPv6 neighbor settings. The Switch’s current IPv6 neighbor settings will be displayed in the table at the bottom of this window.

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 4.17 – System > IPv6 Neighbor Settings

Interface Name: Enter the interface name of the IPv6 neighbor.

Neighbor IPv6 Address: Specifies the neighbor IPv6 address.

Link Layer MAC Address: Specifies the link layer MAC address.

Click Apply for the settings to take effect.

Interface Name: Specifies the interface name of the IPv6 neighbor. To search for all the current interfaces on the Switch, go to the second Interface Name field in the middle part of the window, tick the All check box. Tick the Hardware option to display all the neighbor cache entries which were written into the hardware table.

State: Use the drop-down menu to select All, Address, Static or Dynamic. When the user selects address from the drop-down menu, the user will be able to enter an IP address in the space provided next to the state option.

Click Find to locate a specific entry based on the information entered.

Click Clear to clear all the information entered in the fields.

System > DHCP Auto Configuration

This page allows you to enable the DHCP Auto Configuration feature on the Switch. When enabled, the Switch becomes a DHCP client and gets the configuration file from a TFTP server automatically on next boot up. To accomplish this, the DHCP server must deliver the TFTP server IP address and configuration file name information in the DHCP reply packet. The TFTP server must be up and running and store the necessary configuration file in its base directory when the request is received from the Switch.

Figure 4.18 – System > DHCP Auto Configuration

System > Port Configuration > Port Settings

In the Port Setting page, the status of all ports can be monitored and adjusted for optimum configuration. By selecting a range of ports (From Port and To Port), the Speed can be set for all selected ports by clicking Apply. Press the Refresh button to view the latest information.

15

4 Configuration

DGS-1210 series Metro Ethernet Managed Switch User Manual

 

 

Figure 4.19 – System > Port Configuration > Port Settings

Media: Depending on the selected port type, two options for user. Copper and Fiber_1G. State: Enable or disable the state of specified ports.

Speed: Gigabit Fiber connections can operate in 1000M Full Force Mode, Auto Mode or Disabled. Copper connections can operate in Forced Mode settings (1000M Full, 100M Full, 100M Half, 10M Full, 10M Half), Auto, or Disabled. The default setting for all ports is Auto.

NOTE: Be sure to adjust port speed settings appropriately after changing the connected cable media types.

MDI/MDIX:

A medium dependent interface (MDI) port is an Ethernet port connection typically used on the Network Interface Card (NIC) or Integrated NIC port on a PC. Switches and hubs usually use Medium dependent interface crossover (MDIX) interface. When connecting the Switch to end stations, user have to use straight through Ethernet cables to make sure the Tx/Rx pairs match up properly. When connecting the Switch to other networking devices, a crossover cable must be used.

This switch provides a configurable MDI/MDIX function for users. The switches can be set as an MDI port in order to connect to other hubs or switches without an Ethernet crossover cable.

Auto is designed on the switch to detect if the connection is backwards, and automatically chooses MDI or

MDIX to properly match the connection. The default setting is “Auto” MDI/MDIX.

Flow Control: You can enable this function to mitigate the traffic congestion. Ports configured for full-duplex use 802.3x flow control, half-duplex ports use backpressure flow control. The default setting is Disabled.

System > Port Configuration > Port Description

In the Port Description page, the user may name various ports on the Switch.

Figure 4.20 – System > Port Configuration > Port Description

From Port / To Port: Specify the range of ports to describe.

Medium Type: Depending on the selected port type, two options for user. Copper and Fiber_1G.

Loading...
+ 106 hidden pages