D-Link DGS-1008G User Manual

0 (0)
D-Link DGS-1008G User Manual

ENGLISH

Preface

D-Link reserves the right to revise this publication and to make changes in the content hereof without obligation to notify any person or organization of such revisions or changes.

Manual Revisions

Revision

Date

Description

1.0February 19, 2010 DGS-1008G - Hardware revision A1

1.1

May 18, 2010

Added Windows® 7 Support

Trademarks

D-Link and the D-Link logo are trademarks or registered trademarks of D-Link Corporation or its subsidiaries in the United States or other countries. All other company or product names mentioned herein are trademarks or registered trademarks of their respective companies.

Copyright Statement

No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems, Inc., as stipulated by the United States Copyright Act of 1976 and any amendments thereto. Contents are subject to change without prior notice.

Copyright ©2010 by D-Link Corporation/D-Link Systems, Inc. All rights reserved.

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

2

ENGLISH

Table of Contents

Preface..............................................................................................

2

Manual Revisions..........................................................................................

2

Trademarks......................................................................................................

2

Copyright Statement...................................................................................

2

FCC Statement...............................................................................................

2

Safety Instructions..........................................................................

4

Safety Cautions..............................................................................................

4

Protecting Against Electrostatic Discharge.........................................

6

Product Overview...........................................................................

7

Package Contents.........................................................................................

7

Setup.................................................................................................................

7

Introduction....................................................................................................

7

D-Link Green Ethernet Technology...............................................

7

Fast Ethernet Technology.................................................................

8

Gigabit Ethernet Technology..........................................................

8

Switching Technology........................................................................

9

802.1p Priority Tagging......................................................................

9

Jumbo Frame Support.......................................................................

9

Features..........................................................................................................

10

Hardware Overview...................................................................................

11

Top Panel (LEDs).................................................................................

11

Rear Panel (Connections)................................................................

13

Installation.....................................................................................

14

Before You Connect to the Network....................................................

14

Mounting the Switch on the Wall.........................................................

15

Mounting on a cement wall...........................................................

15

Mounting on a wood wall..............................................................

15

Connecting the Switch.............................................................................

16

DGS-1008G to End Node.................................................................

16

Hub/Switch to DGS-1008G.............................................................

16

Connecting To Network Backbone or Server..........................

16

Troubleshooting............................................................................

17

Networking Basics.........................................................................

18

Check your IP address...............................................................................

18

Statically Assign an IP address...............................................................

19

Glossary.........................................................................................

20

Technical Specifications................................................................

25

RJ-45 Pin Specifications............................................................................

26

Contacting Technical Support......................................................

27

Registration...................................................................................

28

3

ENGLISH

Safety Instructions

Use the following safety guidelines to ensure your own personal safety and to help protect your system from potential damage.

Safety Cautions

To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions.

Observe and follow service markings. Do not service any product except as explained in your system documentation. Opening or removing covers that are marked with the triangular symbol with a lightning bolt may expose you to an electrical shock. Only a trained service technician should service components inside these compartments.

If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your trained service provider:

The power cable, extension cable, or plug is damaged.

An object has fallen into the product.

The product has been exposed to water.

The product has been dropped or damaged.

The product does not operate correctly when you follow the operating instructions.

Keep your system away from radiators and heat sources. Also, do not block cooling vents.

Do not spill food or liquids on your system components, and never operate the product in a wet environment. If the system gets wet, see the appropriate section in your troubleshooting guide or contact your trained service provider.

Do not push any objects into the openings of your system. Doing so can cause a fire or an electric shock by shorting out interior components.

Use the product only with approved equipment.

Allow the product to cool before removing covers or touching internal components.

Operate the product only from the type of external power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult your service provider or local power company.

4

• To help avoid damaging your system, be sure the voltage selection switch (if provided) on the power supply is set to match the

 

power available at your location:

 

– 115 volts (V)/60 hertz (Hz) in most of North and South America and some Far Eastern

 

countries such as South Korea andTaiwan.

 

– 100 V/50 Hz in eastern Japan and 100 V/60 Hz in western Japan.

 

– 230 V/50 Hz in most of Europe, the Middle East, and the Far East.

 

• Also be sure that attached devices are electrically rated to operate with the power available in your location.

 

• Useonlyapprovedpowercable(s).IfyouhavenotbeenprovidedwithapowercableforyoursystemorforanyAC-poweredoption

 

intended for your system, purchase a power cable that is approved for use in your country. The power cable must be rated for the

 

product and for the voltage and current marked on the product’s electrical ratings label. The voltage and current rating of the

ENGLISH

cable should be greater than the ratings marked on the product.

• To help prevent an electric shock, plug the system and peripheral power cables into properly grounded electrical outlets.These

 

 

cables are equipped with three-prong plugs to help ensure proper grounding. Do not use adapter plugs or remove the grounding

 

prong from a cable. If you must use an extension cable, use a 3-wire cable with properly grounded plugs.

 

• Observeextensioncableandpowerstripratings.Makesurethatthetotalampereratingof all products plugged into the extension

 

cable or power strip does not exceed 80 percent of the ampere ratings limit for the extension cable or power strip.

 

• Tohelpprotectyoursystemfromsudden,transientincreasesanddecreasesinelectricalpower,useasurgesuppressor,lineconditioner,

 

or uninterruptible power supply (UPS).

 

• Position system cables and power cables carefully; route cables so that they cannot be stepped on or tripped over. Be sure that

 

nothing rests on any cables.

 

• Donotmodifypowercablesorplugs.Consultalicensedelectricianoryourpowercompanyforsitemodifications.Alwaysfollowyour

 

local/national wiring rules.

 

• When connecting or disconnecting power to hot-pluggable power supplies, if offered with your system, observe the following

 

guidelines:

 

– Install the power supply before connecting the power cable to the power supply.

 

– Unplug the power cable before removing the power supply.

 

– If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power

 

supplies.

5

Protecting Against Electrostatic Discharge

Static electricity can harm delicate components inside your system. To prevent static damage, discharge static electricity from your body before you touch any of the electronic components, such as the microprocessor. You can do so by periodically touching an unpainted metal surface on

 

the chassis.

 

You can also take the following steps to prevent damage from electrostatic discharge (ESD):

 

1.

When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic packing

 

 

material until you are ready to install the component in your system. Just before unwrapping the antistatic packaging, be sure to

 

 

discharge static electricity from your body.

ENGLISH

 

2.

When transporting a sensitive component, first place it in an antistatic container or packaging.

 

 

3.

Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads, workbench pads, and an antistatic grounding

 

 

strap.

6

 

Product Overview

Package Contents

D-Link DGS-1008G 8-port Gigabit Desktop Switch

Warranty Card

Wall Mount Kit

Quick Install Guide

Power Adapter

 

ENGLISH

Setup

The setup of the DGS-1008G can be performed using the following steps:

The power outlet should be within 1.82 meters (6 feet) of the Switch.

Visually inspect the DC power jack and make sure that it is fully secured to the power adapter.

Do not cover the ventilation holes on the sides of the Switch, and make sure there is adequate ventilation around it.

Do not place heavy objects on the switch.

Introduction

D-Link Green Ethernet Technology

D-Link Green Ethernet Technology implements special power-saving features under speed at 1000Mbps that detect cable length and link status and adjust power usage accordingly.

Green Ethernet Technology saves energy in two specific ways:

1.Ifthereisnolinkonaport(whenthereisnoconnectionorthedeviceconnectedisturnedoff)theport(s)willentera“sleepmode” which will drastically reduce the amount of power used.

2.D-Link Green Ethernet Technology detects the length of connected Ethernet cable and adjusts power usage accordingly without affectingperformance.Thisway,aportconnectedtoa20mcableonlyusesasmuchpowerasitneeds,insteadofusingfullpower, which is only needed for 100m cables.

7

ENGLISH

Fast Ethernet Technology

The growing importance of LANs and the increasing complexity of desktop computing applications are fueling the need for high performance networks. 100BASE-TX (Fast Ethernet) provides a cost-effective and high-performance solution for small workgroups, SMBs (Small to Medium

Businesses), and any network supporting bandwidth-intensive applications. Fast Ethernet technology operates at 10 times the speed of traditional

Ethernet, offering maximum performance and enhanced capability for existing Ethernet-based networks.

100Mbps Fast Ethernet is a standard specified by the IEEE 802.3 LAN committee. It is an extension of the 10Mbps Ethernet standard with the ability to transmit and receive data at 100Mbps, while maintaining the CSMA/CD Ethernet protocol. Since the 100Mbps Fast Ethernet is compatible with all other 10Mbps Ethernet environments, it provides a straightforward upgrade and takes advantage of the existing investment in hardware, software, and personnel training.

Gigabit Ethernet Technology

Gigabit Ethernet is an extension of IEEE 802.3 Ethernet utilizing the same packet structure, format, and support for CSMA/CD protocol, full duplex, flow control, and management objects, but with a tenfold increase in theoretical throughput over 100Mbps Fast Ethernet and a one hundredfold increase over 10Mbps Ethernet. Since it is compatible with all 10Mbps and 100Mbps Ethernet environments, Gigabit Ethernet provides a straightforward upgrade without wasting a company’s existing investment in hardware, software, and trained personnel.

TheincreasedspeedandextrabandwidthofferedbyGigabitEthernetareessentialtocopingwiththenetworkbottlenecksthatfrequentlydevelop as computers and their busses get faster and more users use applications that generate more traffic. Upgrading key components, such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks.

Gigabit Ethernet enables fast optical fiber connections to support video conferencing, complex imaging, and similar data-intensive applications. Likewise, since data transfers occur 10 times faster than Fast Ethernet, servers outfitted with Gigabit Ethernet NIC’s are able to perform 10 times the numberofoperationsinthesameamountoftime.Inaddition,thephenomenalbandwidthdeliveredbyGigabitEthernetisthemostcost-effective method to take advantage of today and tomorrow’s rapidly improving switching and routing internetworking technologies

8

ENGLISH

Switching Technology

Switches provide full-line speed and dedicated bandwidth for all connections. This is in contrast to hubs, which use the traditional shared networking topology, where the connected nodes contend for the same network bandwidth. When two switching nodes are communicating, they are connected with a dedicated channel between them, so there is no contention for network bandwidth with other nodes. As a result, the switch reduces considerably, the likelihood of traffic congestion.

For Ethernet networks, a switch is an effective way of eliminating the problem of chaining hubs beyond the“two-repeater limit.”A switch can be used to split parts of the network into different collision domains, making it possible to expand your Ethernet network beyond the 205-meter network diameter limit for 100BASE-TX networks. Switches supporting both 10Mbps Ethernet and 100Mbps Fast Ethernet are also ideal for bridging between existing 10Mbps networks and newer 100Mbps networks.

Switching LAN technology is a marked improvement over the previous generation of network hubs and bridges, which were characterized by higher latencies. Routers have also been used to segment local area networks, but the cost of a router, the setup and maintenance required, make routers relatively impractical. Today switches are an ideal solution to most kinds of local area network congestion problems.

802.1p Priority Tagging

802.1p places a tag in a frame to indicate the priority of the frame. A tag will represent a priority of 0-7 and an 802.1p compliant switch can read this tag and prioritize traffic accordingly. In 802.1p a port can receive frames with varying priority tags and classify them based on these tags. A VoIP phone that supports 802.1p can assign a priority to its VoIP traffic and when it enters the switch the switch can give it a higher priority so that voice traffic is always clear and jitter free. The DGS-1008G supports the 802.1p feature with 4 preconfigured priority queues. When a frame tagged with an 802.1p priority bit is received by the switch it places the frame into one of 4 queues prioritized according to its tag number. For example, traffic tagged with a priority bit of 7 will have a higher priority then traffic tagged with a priority bit of 6 and so forth.

Jumbo Frame Support

The DGS-1008G switch supports Jumbo Frames up to 9720 Bytes in size. Jumbo Frame support is designed to improve network throughput and significantly reduce the CPU utilization of large file transfers such as multimedia files or large data files by enabling more efficient larger payloads per packet.

9