SGS Thomson Microelectronics LD1084V, LD1084D2T90, LD1084D2T50, LD1084D2T36, LD1084D2T33 Datasheet

...
0 (0)
SGS Thomson Microelectronics LD1084V, LD1084D2T90, LD1084D2T50, LD1084D2T36, LD1084D2T33 Datasheet

LD1084

SERIES

5A LOW DROP POSITIVE VOLTAGE REGULATOR ADJUSTABLE AND FIXED

TYPICAL DROPOUT 1.3V (AT 5A)

THREE TERMINAL ADJUSTABLE OR FIXED OUTPUT VOLTAGE 1.5, 1.8V, 2.5V, 2.85V, 3.3V, 3.6V, 5V, 8V, 9V, 12V.

GUARANTEED OUTPUT CURRENT UP TO 5A

OUPUT TOLERANCE ±1% AT 25°C AND

±2% IN FULL TEMPERATURE RANGE

INTERNAL POWER AND THERMAL LIMIT

WIDE OPERATING TEMPERATURE RANGE -40°C TO 125°C

PACKAGE AVAILABLE : TO-220, D2PAK, D2PAK/A

PINOUT COMPATIBILITY WITH STANDARD ADJUSTABLE VREG

DESCRIPTION

The LD1084 is a LOW DROP Voltage Regulator able to provide up to 5A of Output Current. Dropout is guaranteed at a maximum of 1.5V at the maximum output current, decreasing at lower loads. The LD1084 is pin to pin compatible with the older 3-terminal adjustable regulators, but has better performances in term of drop and output tolerance .

D2PAK

TO-220

D2PAK/A

A 2.85V output version is suitable for SCSI-2 active termination. Unlike PNP regulators, where a part of the output current is wasted as quiescent current, the LD1084 quiescent current flows into the load, so increase efficiency. Only a 10µF minimum capacitor is need for stability.

The device is supplied in TO-220, D2PAK and D2PAK/A. On chip trimming allows the regulator to reach a very tight output voltage tolerance, within ±1% at 25°C.

SCHEMATIC DIAGRAM

May 2003

1/18

LD1084 SERIES

ABSOLUTE MAXIMUM RATINGS

Symbol

Parameter²

Value

Unit

 

 

 

 

VI

DC Input Voltage

30

V

IO

Output Current

Internally Limited

mA

PD

Power Dissipation

Internally Limited

mW

Tstg

Storage Temperature Range

-55 to +150

°C

Top

Operating Junction Temperature Range

-40 to +125

°C

Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these condition is not implied.

THERMAL DATA

Symbol

Parameter

TO-220

D2PAK

Unit

Rthj-case

Thermal Resistance Junction-case

3

3

°C/W

Rthj-amb

Thermal Resistance Junction-ambient

50

62.5

°C/W

APPLICATION CIRCUITS

R2

VO = VREF (1 + ¾¾)

R1

CONNECTION DIAGRAM (top view)

 

TO-220

D2PAK

D2PAK/A

2/18

 

 

 

 

LD1084 SERIES

ORDERING CODES

 

 

 

 

 

 

 

TYPE

D2PAK (*)

D2PAK/A

OUTPUT VOLTAGE

LD1084V15

LD1084D2T15

LD1084D2M15

1.5 V

 

 

 

 

LD1084V18

LD1084D2T18

LD1084D2M18

1.8 V

 

 

 

 

LD1084V25

LD1084D2T25

LD1084D2M25

2.5 V

 

 

 

 

LD1084V28

LD1084D2T28

LD1084D2M28

2.85 V

 

 

 

 

LD1084V33

LD1084D2T33

LD1084D2M33

3.3 V

LD1084V36

LD1084D2T36

LD1084D2M36

3.6 V

 

 

 

 

LD1084V50

LD1084D2T50

LD1084D2M50

5.0 V

 

 

 

 

LD1084V80

LD1084D2T80

LD1084D2M80

8.0 V

 

 

 

 

LD1084V90

LD1084D2T90

LD1084D2M90

9.0 V

 

 

 

 

LD1084V120

LD1084D2T120

LD1084D2M120

12.0 V

 

 

 

 

LD1084V

LD1084D2T

LD1084D2M

ADJ

 

 

 

 

(*) Available in Tape & Reel with the suffix "R" for fixed versions and "-R" for adjustable version

LECTRICAL CHARACTERISTICS OF LD1084#15 (VI=4.5V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

1.485

1.5

1.515

V

 

 

IO = 0 to 5A

VI = 3.1 to 30V (note 1)

1.47

1.5

1.53

V

VO

Line Regulation

IO = 0 mA

VI = 3.1 to 18V TJ = 25°C

 

0.5

6

mV

 

 

IO = 0 mA

VI = 3.1 to 15V

 

0.1

6

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

3

15

mV

 

 

IO = 0 to 5A

 

 

7

20

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

 

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

75

 

dB

 

 

VI = 6.8 ± 3V

 

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

3/18

LD1084 SERIES

ELECTRICAL CHARACTERISTICS OF LD1084#18 (VI=4.8V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

1.782

1.8

1.818

V

 

 

IO = 0 to 5A

VI = 3.4 to 30V (note 1)

1.764

1.8

1.836

V

VO

Line Regulation

IO = 0 mA

VI = 3.4 to 18V TJ = 25°C

 

0.5

6

mV

 

 

IO = 0 mA

VI = 3.4 to 15V

 

0.1

6

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

3

15

mV

 

 

IO = 0 to 5A

 

 

7

20

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

 

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

75

 

dB

 

 

VI = 6.8 ± 3V

 

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

ELECTRICAL CHARACTERISTICS OF LD1084#25 (VI=5.5V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

2.475

2.5

2.525

V

 

 

IO = 0 to 5A

VI = 4.1 to 30V (note 1)

2.45

2.5

2.55

V

VO

Line Regulation

IO = 0 mA

VI = 4.1 to 18V TJ = 25°C

 

0.5

6

mV

 

 

IO = 0 mA

VI = 4.1 to 18V

 

0.1

6

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

3

15

mV

 

 

IO = 0 to 5A

 

 

7

20

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

 

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

72

 

dB

 

 

VI = 7.5 ± 3V

 

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

4/18

LD1084 SERIES

ELECTRICAL CHARACTERISTICS OF LD1084#285 (VI=5.85V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

 

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

2.821

2.85

2.879

V

 

 

IO = 0 to 5A

VI = 4.5 to 30V (note 1)

2.793

2.85

2.907

V

VO

Line Regulation

IO = 0 mA

VI = 4.5 to 18V TJ = 25°C

 

0.5

6

mV

 

 

IO = 0 mA

VI = 4.5 to 18V

 

0.1

6

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

3

15

mV

 

 

IO = 0 to 5A

 

 

7

20

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

72

 

dB

 

 

VI = 7.85 ± 3V

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

ELECTRICAL CHARACTERISTICS OF LD1084#33 (VI=6.3V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

3.267

3.3

3.333

V

 

 

IO = 0 to 5A

VI = 4.9 to 30V (note 1)

3.234

3.35

3.366

V

VO

Line Regulation

IO = 0 mA

VI = 4.9 to 18V TJ = 25°C

 

0.5

6

mV

 

 

IO = 0 mA

VI = 4.9 to 18V

 

0.1

6

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

3

15

mV

 

 

IO = 0 to 5A

 

 

7

20

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

 

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

72

 

dB

 

 

VI = 8.3 ± 3V

 

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

5/18

LD1084 SERIES

ELECTRICAL CHARACTERISTICS OF LD1084#36 (VI=6.6V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

3.564

3.6

3.636

V

 

 

IO = 0 to 5A

VI = 5.2 to 30V (note 1)

3.528

3.6

3.672

V

VO

Line Regulation

IO = 0 mA

VI = 5.2 to 18V TJ = 25°C

 

0.5

10

mV

 

 

IO = 0 mA

VI = 5.2 to 18V

 

0.1

10

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

3

15

mV

 

 

IO = 0 to 5A

 

 

7

20

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

 

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

72

 

dB

 

 

VI = 8.6 ± 3V

 

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

ELECTRICAL CHARACTERISTICS OF LD1084#5 (VI=8V, CI = CO =10μF, TA = -40 to 125°C, unless otherwise specified.)

Symbol

Parameter

 

Test Conditions

Min.

Typ.

Max.

Unit

 

 

 

 

 

 

 

 

VO

Output Voltage

IO = 0 mA

TJ = 25°C

4.95

5

5.05

V

 

 

IO = 0 to 5A

VI = 6.6 to 30V (note 1)

4.9

5

5.1

V

VO

Line Regulation

IO = 0 mA

VI = 6.6 to 20V TJ = 25°C

 

0.5

10

mV

 

 

IO = 0 mA

VI = 6.6 to 20V

 

1

10

mV

VO

Load Regulation

IO = 0 to 5A

TJ = 25°C

 

5

20

mV

 

 

IO = 0 to 5A

 

 

10

35

V

Vd

Dropout Voltage

IO =5 A

 

 

1.3

1.5

V

Iq

Quiescent Current

VI 30V

 

 

5

10

mA

Isc

Short Circuit Current

VI - VO = 5V

 

5.5

6.5

 

A

 

 

VI - VO = 25V

0.5

0.7

 

A

 

Termal Regulation

TA = 25°C, 30ms pulse

 

0.003

0.015

%/W

SVR

Supply Voltage Rejection

f = 120 Hz,

CO = 25 μF, IO = 5A

60

72

 

dB

 

 

VI = 10 ± 3V

 

 

 

 

 

eN

RMS Output Noise Voltage

TA = 25°C f =10Hz to 10KHz

 

0.003

 

%

 

(% of VO)

 

 

 

 

 

 

S

Temperature Stability

 

 

 

0.5

 

%

 

 

 

 

 

 

 

 

S

Long Term Stability

TA = 125°C

1000Hrs

 

0.5

 

%

NOTE 1: See short-circuit current curve for available output current at fixed dropout.

6/18

Loading...
+ 12 hidden pages