Intel Xeon 5600 Series Processors—
Information Update
•Your system requires a BIOS and iDRAC firmware upgrade to support Intel Xeon 5600 series processor (less than 130 W). You can download the BIOS and iDRAC firmware for the Intel Xeon 5600 series processor at support.dell.com.
NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of the Intel Xeon 5600 series processor.
•The following new Dell PowerEdge systems marked with the Roman Numeral II on the chassis support the complete feature set of Intel Xeon 5600 series processors:
–R410
–R510
–R610
–R710
–T410
–T610
–T710
–M610
–M710
NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W Intel Xeon 5600 series processors.
NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W Intel Xeon X5680 only in the 130 W processor category.
NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support the 130 W Intel Xeon 5600 series processors.
•Mixing of Intel Xeon 5500 and 5600 series processors is not supported.
•Systems with the Intel Xeon 5600 series processors support memory sparing.
2011 - 12 |
A02 |
Intel Xeon 5600 series processors support DDR3L DIMMs enabling a lower operating voltage (1.35 V) that ensures memory power savings up to 20% per DIMM. DDR3L memory is backward-compatible to Intel Xeon 5500 series and operates at standard voltage (1.5 V) without any limitations.
Operating the system memory at a lower voltage may cause restrictions to additional frequency and memory population capabilities. For example, populating three memory modules per channel is not supported at 1.35 V.
Systems with 1.35 V DDR3L memory operates the memory modules at 1.5 V if any of the following conditions exist:
•Intel Xeon 5500 series processors
•Two 1333 MHz DIMMs per channel
•A combination of both standard and low voltage memory modules
For information on the memory configuration guidelines, see your system’s
Hardware Owner’s Manual at support.dell.com/manuals.
NOTE: BIOS setup options allow the user to control frequency and voltage configuration within allowable limits.
Option Description
SR-IOV-Global Enable |
Enables/disables BIOS configuration of Single Root |
(Disabled default) |
I/O Virtualization (SR-IOV) devices. |
|
NOTE: Applies to PowerEdge R410, R510, R610, R710, R910, |
|
T410, T610, and T710 systems only. |
|
|
Option |
Description |
|
|
System Memory Voltage |
Displays the system memory voltage. |
Memory Operating Voltage |
Sets the system memory voltage selection. |
(Auto Default) |
|
|
|
Memory Operating Mode |
Displays the type of memory operation if a valid memory |
|
configuration is installed. When set to Optimizer mode, the |
|
memory controllers run independent of each other for |
|
improved memory performance. When set to Mirror mode, |
|
memory mirroring is enabled. When set to Advanced ECC |
|
Mode, two controllers are joined in 128-bit mode running |
|
multi-bit advanced ECC. The Spare mode option is present |
|
on systems with the Intel Xeon 5600 series processors only. |
|
|
Option |
Description |
|
|
C1E (Enabled default) |
Sets the processor performance state to minimum |
|
when the system is idle. |
|
|
Intel QPI Bandwidth Priority |
Sets the bandwidth priority to compute or I/O. |
(Compute default) |
Recommended for HPC applications. |
|
|
Adjacent Cache Line Prefetch |
Enables high utilization of sequential memory access. |
(Enabled default) |
NOTE: Disable this option for applications that require |
|
|
|
high utilization of random memory access. |
|
|
Hardware Prefetcher |
Enables or disables the hardware prefetcher. |
(Enabled default) |
|
|
|
DCU Streamer Prefetcher |
Enables Data Cache Unit streamer prefetcher. |
(Enabled default) |
Recommended for HPC applications. |
|
|
Data Reuse |
Enables or disables data reuse. Recommended |
(Enabled default) |
for HPC applications. |
|
|
Option |
Description |
Intel(R) TXT (Disabled Enables/disables Trusted Execution Technology. To enable default) TXT, enable & activate VT & TPM with pre-boot
measurement.
The following are the new POST messages for the Intel Xeon 5600 series processors.
Message |
Description |
|
|
System Memory Size: |
Displays the amount of system memory, system |
X.X GB, System Memory |
memory speed, and current system memory |
Speed: XXX MHz, |
operating voltage. |
Voltage: 1.5V or 1.35V |
|
|
|
This CPU power rating |
This message displays when either of the following |
is not supported |
occurs: |
|
• The Intel Xeon 5600 130 W series processor is |
|
detected on an old system board (systems not marked |
|
with roman numeral II). For a list of the supported |
|
systems, see Important Information. |
|
• The Intel Xeon X5677 130 W series quad-core |
|
processor is detected on PowerEdge M610 and |
|
M710. |
|
|
Non-ECC DIMM detected |
Displays when the system detects a non-ECC |
on DIMM XX |
memory module. |
|
|
The Dell BIOS Intelligent Turbo Mode feature allows the operating system to set the processor performance in the turbo mode. Based on the processor utilization, this feature delays the processor turbo mode initiation for better power management. When the turbo mode is enabled in the Processor Settings screen of the system setup, the feature can be enabled or disabled using the following BIOS setup options:
NOTE: The Dell BIOS Intelligent Turbo Mode is disabled when the turbo mode is disabled in the processor system setup screen.
Setup Screen |
Field |
Field value |
Intelligent Turbo |
|
|
|
|
Power Management |
CPU Power and |
OS DBPM |
Enabled |
|
Performance Management |
|
|
|
|
|
|
Power Management |
CPU Power and |
System DBPM |
Disabled |
|
Performance Management |
|
|
|
|
|
|
Power Management |
CPU Power and |
Maximum |
Disabled |
|
Performance Management |
Performance |
|
|
|
|
|
____________________
Information in this publication is subject to change without notice. © 2010–2011 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc. Intel® and Xeon® are registered trademarks of Intel Corporation in the U.S. and other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Intel Xeon 5600 —
•BIOS iDRAC Intel Xeon 5600130 W Intel Xeon 5600 BIOS iDRAC support.dell.com
BIOS iDRAC Intel Xeon 5600
•“II” Dell PowerEdge Intel Xeon 5600
–R410
–R510
–R610
–R710
–T410
–T610
–T710
–M610
–M710
PowerEdge R410 T410 R510 130 W Intel Xeon 5600
PowerEdge M610 M710 130 W 130
W Intel Xeon X5680
PowerEdge R610 M710 130 W Intel
Xeon 5600
•Intel Xeon 5500 5600
•Intel Xeon 5600
2011 12 |
A02 |
(DDR3L DIMM)
Intel Xeon 5600 DDR3L DIMM (1.35 V) DIMM 20% DDR3L Intel Xeon 5500 (1.5 V)
1.35 V
1.35 V DDR3L 1.5 V
•Intel Xeon 5500
•1333 MHz DIMM
support.dell.com/manuals
BIOS
BIOS
Integrated Devices
|
|
||
|
|
||
SR-IOV-Global Enable |
/ I/O (SR-IOV) BIOS |
||
SR-IOV |
|
||
Disabled |
PowerEdge R410 R510 R610 R710 |
||
[ |
|
||
|
|||
] |
R910 T410 T610 T710 |
||
|
|
Memory Settings
|
|
|
|
System Memory Voltage |
|
|
|
Memory Operating Voltage
Auto [ ]
Memory Operating Mode Optimizer mode Mirror modeAdvanced ECC
Mode ECC 128 ECC Spare modeIntel Xeon 5600
Processor Settings
|
|
|
|
|
|
||
C1E Enabled |
|
||
[ ] |
|
|
|
|
|
||
Intel QPI Bandwidth Priority |
compute I/O |
||
Intel QPI |
HPC |
|
|
Compute [ ] |
|
|
|
|
|
|
|
Adjacent Cache Line Prefetch |
|
|
|
|
|
||
Enabled [ |
|
|
|
] |
|
|
|
|
|
|
|
Hardware Prefetcher |
|
|
|
|
|
|
|
Enabled [ ] |
|
|
|
DCU Streamer Prefetcher |
|
Data Cache Unit streamer prefetcher |
|
|
|
|
|
DCU |
HPC |
||
Enabled |
|
|
|
[ ] |
|
|
|
Data Reuse |
HPC |
||
Enabled |
|
|
|
[ ] |
|
|
|
|
|
|
|
System Security
|
|
|
|
|
|
Intel(R) TXT |
/ TXT |
|
Disabled [ |
|
VT TPM |
] |
POST
Intel Xeon 5600 POST
|
|
|
|
System Memory Size: |
|
X.X GB, System Memory |
|
Speed: XXX MHz, |
|
Voltage: 1.5V or 1.35V |
|
|
|
This CPU power rating |
|
is not supported |
• “II” |
|
Intel Xeon 5600 130 W |
|
|
|
• PowerEdge M610 M710 Intel |
|
Xeon X5677 130 W |
|
|
Non-ECC DIMM detected |
ECC |
on DIMM XX |
|
|
|
Dell BIOS Turbo
Dell BIOS Turbo turbo turboProcessor Settings turbo BIOS
turbo Dell BIOS
Turbo
|
|
|
|
Turbo |
|
|
|
|
|
Power Management |
CPU Power and |
OS DBPM |
Enabled |
|
|
Performance Management |
|
|
|
|
CPU |
|
|
|
|
|
|
|
|
Power Management |
CPU Power and |
System DBPM |
|
|
|
Performance Management |
|
DBPM |
|
|
|
|
|
|
|
CPU |
|
|
|
|
|
|
|
|
Power Management |
CPU Power and |
Maximum |
|
|
|
Performance Management |
Performance |
|
|
|
CPU |
|
|
|
|
|
|
|
|
____________________
© 2010 – 2011 Dell Inc.
Dell Inc.
Dell™ DELL PowerEdge™ Dell Inc. Intel® Xeon® Intel Corporation /
DellInc.
•Votre système nécessite une mise à niveau du BIOS et du micrologiciel de l'iDRAC afin de prendre en charge le processeur Intel Xeon série 5600 (moins de 130 W). Vous pouvez télécharger le BIOS et le micrologiciel de l'iDRAC pour le processeur Intel Xeon série 5600 à l'adresse support.dell.com.
REMARQUE : La mise à jour du BIOS et du micrologiciel de l'iDRAC ne prend en charge qu'un nombre limité de fonctions du processeur Intel Xeon série 5600.
•Les nouveaux systèmes Dell PowerEdge suivants présentant le chiffre romain II sur leur châssis prennent en charge l'ensemble des fonctions des processeurs Intel Xeon série 5600 :
–R410
–R510
–R610
–R710
–T410
–T610
–T710
–M610
–M710
REMARQUE : Les systèmes PowerEdge R410, T410 et R510 ne prennent pas en charge les processeurs Intel Xeon série 5600 de 130 W.
REMARQUE : Les systèmes modulaires, PowerEdge M610 et M710 prennent en charge uniquement les processeurs Intel Xeon X5680 de 130 W dans la catégorie de processeur 130 W.
REMARQUE : Les systèmes PowerEdge R610 et M710 ont besoin de dissipateurs thermiques spécifiques pour prendre en charge les processeurs Intel Xeon série 5600 de 130 W .
2011 - 12 |
A02 |
•L'utilisation simultanée de processeurs Intel Xeon série 5500 et 5600 n'est pas prise en charge.
•Les sytèmes dotés de processeurs Intel Xeon série 5600 prennent en charge la mémoire de réserve.
Les processeurs Intel Xeon série 5600 prennent en charge les barrettes DIMM DDR3L, qui permettent une tension de fonctionnement plus basse (1,35 V) économisant jusqu'à 20 % d'alimentation de mémoire par barrette. La mémoire DDR3L est rétrocompatible avec les processeurs Intel Xeon série 5500 et fonctionne avec une tension standard (1,5 V), sans limitation.
Si vous utilisez le système sous une tension inférieure, des limitations peuvent s'appliquer aux fréquences supplémentaires ou aux capacités de configuration de la mémoire. Ainsi, l'installation de trois barrettes de mémoire par canal n'est pas prise en charge à 1,35 V.
Les systèmes avec mémoire DDR3L 1,35 V font fonctionner les barrettes de mémoire à 1,5 V si l'une des conditions suivantes s'applique :
•Processeurs Intel Xeon série 5500
•Deux barrettes DIMM 1333 MHz par canal
•Une combinaison de barrettes de mémoire standard et basse tension
Pour plus d'informations sur les consignes de configuration de la mémoire, consultez le Manuel du propriétaire du matériel correspondant à votre système, à l'adresse support.dell.com/manuals.
REMARQUE : Les options de configuration du BIOS permettent à l'utilisateur de contrôler la configuration de la fréquence et de la tension dans des limites autorisées.