Dell PowerEdge C6400 Manual

0 (0)

Dell EMC PowerEdge C6400

Technical Specifications

Regulatory Model: E43S Series

Regulatory Type: E43S001

December 2020

Rev. A03

Notes, cautions, and warnings

NOTE: A NOTE indicates important information that helps you make better use of your product.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

© 2017 - 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

Contents

Chapter 1: Technical specifications...............................................................................................

4

Dimensions of the Dell EMC PowerEdge C6400 enclosure......................................................................................

4

Chassis weight.....................................................................................................................................................................

5

Supported operating systems...........................................................................................................................................

5

PSU specifications..............................................................................................................................................................

5

Chassis management board specifications....................................................................................................................

6

Drives and storage specifications....................................................................................................................................

6

Midplane specifications......................................................................................................................................................

7

Environmental specifications............................................................................................................................................

7

Standard operating temperature specifications.....................................................................................................

7

Expanded operating temperature specifications .................................................................................................

16

Particulate and gaseous contamination specifications........................................................................................

17

Maximum vibration specifications............................................................................................................................

18

Maximum shock specifications.................................................................................................................................

18

Maximum altitude specifications..............................................................................................................................

18

Fresh Air Operation......................................................................................................................................................

18

Contents 3

1

Technical specifications

The technical and environmental specifications of your system are outlined in this section.

Topics:

Dimensions of the Dell EMC PowerEdge C6400 enclosure

Chassis weight

Supported operating systems

PSU specifications

Chassis management board specifications

Drives and storage specifications

Midplane specifications

Environmental specifications

Dimensions of the Dell EMC PowerEdge C6400 enclosure

Figure 1. Dimensions of PowerEdge C6400 enclosure

4 Technical specifications

Table 1. Dimensions of the PowerEdge C6400 enclosure

Xa

Xb

Y

Za

Zb

Zc

 

 

 

 

 

 

 

 

 

 

 

 

482.6 mm (19

448 mm (17.63

86.8 mm (3.41

26.8 mm (1.05

763.2 mm (30.28

797.3 mm (31.38

inches)

inches)

inches)

inches)

inches)

inches)

 

 

 

 

 

 

Chassis weight

Table 2. Chassis weight of the Dell EMC PowerEdge C6400 enclosure with PowerEdge C6420 sleds

System

Maximum weight (with all sleds and drives)

 

 

 

 

12 x 3.5-inch hard drive systems

43.62 Kg (96.16 lb)

 

 

24 x 2.5-inch hard drive systems

41.46 Kg (91.40 lb)

 

 

No backplane systems

34.56 Kg (76.19 lb)

 

 

Supported operating systems

The Dell EMC PowerEdge C6400 supports the following operating systems:

Canonical Ubuntu LTS

Citrix XenServer

Microsoft Windows Server with Hyper-V

Red Hat Enterprise Linux

SUSE Linux Enterprise Server

VMware ESXi

NOTE: For more information about the specific versions and additions, see https://www.dell.com/support/home/drivers/ supportedos/poweredge-c6400

PSU specifications

The Dell EMC PowerEdge C6400 enclosure supports two AC power supply units (PSUs).

Table 3. PSU specifications

PSU wattage

Class

Heat dissipation

Frequency

Voltage

Maximum input

 

 

(maximum)

 

 

current

 

 

 

 

 

 

 

 

 

 

 

 

2400 W AC

Platinum

9000 BTU/hr

50/60 Hz

100–240 V AC,

14 A–16 A

autoranging

 

 

 

 

 

 

 

 

 

 

 

2000 W AC

Platinum

7500 BTU/hr

50/60 Hz

100–240 V AC,

11.5 A

autoranging

 

 

 

 

 

 

 

 

 

 

 

1600 W AC

Platinum

6000 BTU/hr

50/60 Hz

100–240 V AC,

10 A

autoranging

 

 

 

 

 

 

 

 

 

 

 

NOTE: Heat dissipation is calculated using the PSU wattage rating.

NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.

NOTE: If a system with 2400 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1400 W.

Technical specifications

5

Dell PowerEdge C6400 Manual

NOTE: If a system with 2000 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1000 W.

NOTE: If system with 1600 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 800 W.

Chassis management board specifications

Figure 2. Chassis management board specifications

 

 

1.

Fan cage 1 connector for fans 1 and 2

2.

Left midplane signal cable

3.

Chassis management board signal cable to backplane

4.

Chassis management board power connector from PIB

5.

Chassis management board signal cable to PIB

6.

FPGA connector

7.

MCU connector

8.

COM connector

9.

Firmware jumpers

10.

Right midplane signal cable

11.

Fan cage 2 connector for fans 3 and 4

 

 

Drives and storage specifications

The Dell EMC PowerEdge C6400 enclosure supports SAS and SATA hard drives and Solid State Drives (SSDs).

Table 4. Supported drive options for the Dell EMC PowerEdge C6400 enclosure

Maximum number of drives in the enclosure

Maximum number of drives assigned per sled

 

 

 

 

 

 

12 x 3.5-inch drive systems

Three SAS or SATA hard drives and SSDs per sled

 

 

24 x 2.5-inch drive systems

Six SAS or SATA hard drives and SSDs per sled

 

 

24 x 2.5-inch drive systems with NVMe

The NVMe backplane supports either of these configurations:

 

● Two NVMe drives and four SAS or SATA hard drives and

 

 

 

SSDs per sled

 

● Six SAS or SATA hard drives and SSDs per sled

 

 

M.2 SATA drive (optional)

The supported capacity of the M.2 SATA card is up to 240 GB

 

 

 

NOTE: The M.2 SATA card can be installed on the x16

 

 

 

 

 

riser slot (slot 5).

 

 

Micro-SD card (optional) for boot (up to 64 GB)

One on each PCIe riser of each sled

 

 

 

 

6 Technical specifications

Loading...
+ 12 hidden pages