Daikin FDM20JEVLK, RD20JEVLK, FDM25JEVLK, RD25JEVLK, FDM30JEVLK Installation manuals

...
4 (1)

INSTALLATION

MANUAL

R22 SPLIT SERIES

Installation Manual

English

R22 Split Series

 

 

 

MODELS

FDM20JEVLK RD20JEVLK

FDM25JEVLK RD25JEVLK

FDM30JEVLK RD30JEVLK

FDM40JEVLK RD40JEVLK

FDM50JEVLK RD50JETLK

FDM60JEVLK RD60JETLK

FDYM20JEVLK RYD20JEVLK

FDYM25JEVLK RYD25JEVLK

FDYM30JEVLK RYD30JEVLK

FDYM40JEVLK RYD40JEVLK

FDYM50JEVLK RYD50JETLK

FDYM60JEVLK RYD60JETLK

IM-CCC/E-0311(0)-DAIKIN (SASO)

Part No.: R08019036182

Daikin FDM20JEVLK, RD20JEVLK, FDM25JEVLK, RD25JEVLK, FDM30JEVLK Installation manuals

OUTLINE AND DIMENSIONS

Indoor Unit

All dimensions are in mm

B

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

<![if ! IE]>

<![endif]>H

 

 

 

 

 

 

 

 

O

 

 

 

<![if ! IE]>

<![endif]>L

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>A

 

 

M

N

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

Dimension

A B C D E F G H

I

J K L M N O

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FD(Y)M20JEVLK

31

1041

1002

962

10

1065

72

261

411

351

225

211

232

213

114

FD(Y)M25JEVLK

31

1176

1137

1097

10

1200

72

261

411

351

225

211

232

213

114

Indoor Unit

K

 

All dimensions are in mm

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>J

 

I

 

 

 

H

 

 

 

 

 

L

 

 

 

M

 

 

<![if ! IE]>

<![endif]>G

<![if ! IE]>

<![endif]>N

<![if ! IE]>

<![endif]>B

 

<![if ! IE]>

<![endif]>P

<![if ! IE]>

<![endif]>A

 

 

 

D

E

F

<![if ! IE]>

<![endif]>O

 

 

C

 

 

Dimension

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FD(Y)M30JEVLK

40

292

1295

232

213

70

128

1228

1185

284

1262

460

420

241

12

230

FD(Y)M40JEVLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>Original Instruction English

1-1

Indoor Unit

All dimensions are in mm

E E

K

A

A

K

 

 

B

 

 

 

C

 

G

 

D

H

<![if ! IE]>

<![endif]>L

 

<![if ! IE]>

<![endif]>I

 

<![if ! IE]>

<![endif]>F

<![if ! IE]>

<![endif]>J

M

N

 

Dimension

A

B

C

D

E

F

G

H

I

J

K

L

M

N

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FD(Y)M50JEVLK

359

1369

1326

1287

594

384

541

256

173

306

256

161

248

220

FD(Y)M60JEVLK

359

1569

1526

1487

694

378

541

256

173

306

356

161

248

220

Outdoor Unit

L K L

<![if ! IE]>

<![endif]>M T N

All dimensions are in mm

A

O D

<![if ! IE]>

<![endif]>P

<![if ! IE]>

<![endif]>B

<![if ! IE]>

<![endif]>Q

<![if ! IE]>

<![endif]>N

C

 

G H

<![if ! IE]>

<![endif]>E F

<![if ! IE]>

<![endif]>R S

I J

Dimension

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R(Y)D20JEVLK

855

628

328

508

181

44

93

149

101

113

603

126

164

15

49

3

23

73

75

362

R(Y)D25JEVLK

855

730

328

520

182

44

93

149

101

113

603

126

164

15

34

3

23

73

75

362

R(Y)D30JEVLK

855

730

328

513

182

44

93

149

101

113

603

126

164

15

47

3

23

73

75

362

1-2

Outdoor Unit

All dimensions are in mm

A

N M

P

<![if ! IE]>

<![endif]>L

<![if ! IE]>

<![endif]>K

 

 

C

 

D

T

 

 

<![if ! IE]>

<![endif]>B

<![if ! IE]>

<![endif]>F

 

 

R

 

 

<![if ! IE]>

<![endif]>E

 

 

G

<![if ! IE]>

<![endif]>H

 

<![if ! IE]>

<![endif]>S

 

U

 

 

Q

J

 

 

Dimension

A B C D E F G H J K L M N P Q R S T U

Model

 

 

R(Y)D40JEVLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R(Y)D50JETLK

1030

852

428

410

412

827

72

196

91

488

448

142

141

83

23

49

26

28

80

R(Y)D60JETLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>English

1-3

INSTALLATION MANUAL

This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit.

Special adjustment may be necessary to suit local requirements.

Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.

SAFETY PRECAUTIONS

!WARNING

Installation and maintenance should be performed by qualiÀed persons who are familiar with local code and regulation, and experienced with this type of appliance.

All Àeld wiring must be installed in accordance with the national wiring regulation.

Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.

The unit must be GROUNDED to prevent possible hazard due to insulation failure.

All electrical wiring must not touch the refrigerant piping, or any moving parts of the fan motors.

ConÀrm that the unit has been switched OFF before installing or servicing the unit.

Disconnect from the main power supply before servicing the air conditioner unit.

DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in Àre hazards.

Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. (Depending on the type and source of the electrical waves, static may be heard even when more than 1m away).

! CAUTION

Please take note of the following important points when installing.

Do not install the unit where leakage of Áammable gas may occur.

If gas leaks and accumulates around the unit, it may cause Àre ignition.

Ensure that drainage piping is connected properly.

If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture.

Do not overcharge the unit.

This unit is factory pre-charged.

Overcharge will cause over-current or damage to the compressor.

Ensure that the unit·s panel is closed after service or installation.

Unsecured panels will cause the unit to operate noisily.

Sharp edges and coil surfaces are potential locations which may cause injury hazards.

Avoid from being in contact with these places.

Before turning off the power supply, set the remote controller·s ON/OFF switch to the “OFF” position to prevent the nuisance tripping of the unit. If this is not done, the unit·s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.

Do not install the units at or near doorway.

Do not operate any heating apparatus too close to the air conditioner unit or use in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction.

When the unit is used in kitchen, keep Áour away from going into suction of the unit.

This unit is not suitable for factory used where cutting oil mist or iron powder exist or voltage Áuctuates greatly.

Do not install the units at area like hot spring or oil reÀnery plant where sulphide gas exists.

Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.

IMPORTANT: DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.

Don·t use joined and twisted wires for incoming power supply.

The equipment is not intended for use in a potentially explosive atmosphere.

NOTICE

Disposal requirements

Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.

Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualiÀed installer in accordance with relevant local and national legislation.

Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information.

Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.

1-4

IMPORTANT & SEQUENCE AS FOLLOW:

For model FD(Y)M20JEVLK & FD(Y)M25JEVLK:

2) Left Cushion

3) Right Cushion

4) Indoor Unit

1) Carton Box

UNPACKING

1)After take off the bands, lift the unit out from the carton box

2)Remove the right and left cushion.

For model FD(Y)M30JEVLK & FD(Y)M40JEVLK:

1) Carton Box

<![if ! IE]>

<![endif]>English

2) Top Carton

3) Indoor Unit

4) Bottom Carton

UNPACKING

1)After take off the bands, lift the carton box

2)Remove the top cushion.

3)Lift the unit and remove the bottom carton.

1-5

For model FR(Y)M50JEVLK & FD(Y)M60JEVLK:

1) Carton Box

2) Top Cushion

3) Indoor Unit

4) Packing bottom

UNPACKING

1)After take off the bands, lift the carton box

2)Remove the top cushion.

3)Lift the unit and remove the bottom carton.

For model R(Y)D20JEVLK, R(Y)D25JEVLK, R(Y)D30JEVLK, R(Y)D40JEVLK, R(Y)D50JETLK & R(Y)D60JETLK:

1. After take off the bands, pull out the carton box from the top side of the unit.

* This product is not designed for re-packing. In case of re-packing, contact to Daikin Dealer. 1-6

INSTALLATION DIAGRAM

Indoor unit

Hanger

Return Duct

Supply Duct

Wrap the insulated pipe with the Ànishing tape from bottom to top

Drain Piping

Thermal Insulation

Air Intake

Air Intake

Air Discharge

Outdoor unit

<![if ! IE]>

<![endif]>English

1-7