Daikin FTS20JEV1K, RS20JEV1K, FTS25JEV1K, RS25JEV1K Installation manuals

0 (0)

INSTALLATION

MANUAL

R410A SPLIT SERIES

Installation Manual

R410A Split Series English

MODELS

FTS20JEV1K RS20JEV1K

FTS25JEV1K RS25JEV1K

IM-5WMJ-0811(0)-DAIKIN

Part No.: R08019036975

OUTLINE AND DIMENSIONS

Indoor Unit

THE MARK SHOWS PIPING DIRECTION

REAR

REAR

LEFT RIGHT

TOP VIEW

 

A

C

 

 

 

 

 

 

 

NAME PLATE

 

 

SIGNAL

B

 

 

RECEIVER

 

 

 

 

 

 

TERMINAL

 

 

 

BLOCK

BOTTOM

BOTTOM

SIDE VIEW

WITH EARTH

TERMINAL

 

LOUVER

INDOOR UNIT

 

 

FRONT GRILLE FIXED SCREWS

ON/OFF SWITCH

 

 

(INSIDE)

ROOM TEMPERATURE

 

 

 

 

 

FRONT VIEW

THERMISTOR (INSIDE)

 

All dimensions are in mm

Recommended mounting plate retention spots (7 spots in all)

 

D

 

 

 

 

 

 

 

 

E

 

 

 

 

<![if ! IE]>

<![endif]>F

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>F

 

 

<![if ! IE]>

<![endif]>B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Through the wall

 

 

 

 

 

 

 

 

 

 

 

 

hole Ø 65mm

 

<![if ! IE]>

<![endif]>G

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>G

 

 

H

J

 

Liquid pipe end

M

Gas pipe end

 

 

K

I

Drain hose position

 

 

L

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION PLATE FTS20/25JEV1K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in mm

Dimension

A

B

C

D

E

F

G

H

I

J

K

L

M

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FTS20/25JEV1K

 

1065

310

228

190

173

61

40

45

48

91

219

580

45

<![if ! IE]>

<![endif]>Original Instruction English

1

Outdoor Unit

L

K

L

All dimensions are in mm

 

 

 

<![if ! IE]>

<![endif]>N

 

 

 

<![if ! IE]>

<![endif]>M

 

 

 

<![if ! IE]>

<![endif]>C

<![if ! IE]>

<![endif]>P

<![if ! IE]>

<![endif]>N

 

 

A

C

 

 

 

O

D

G

H

<![if ! IE]>

<![endif]>Q

 

<![if ! IE]>

<![endif]>F

 

<![if ! IE]>

<![endif]>E

<![if ! IE]>

<![endif]>B

<![if ! IE]>

<![endif]>S T

<![if ! IE]>

<![endif]>R

I J

Dimension

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS20JEV1K

855

628

328

508

181

44

93

149

101

113

603

126

164

17

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS25JEV1K

855

730

328

520

182

44

93

149

101

113

603

126

164

17

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimension

P

Q

R

S

T

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS20JEV1K

32

3

23

73

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS25JEV1K

32

3

23

73

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

INSTALLATION MANUAL

This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirement.

Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.

This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.

This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

SAFETY PRECAUTIONS

!WARNING

Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance.

All field wiring must be installed in accordance with the national wiring regulation.

Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.

The unit must be GROUNDED to prevent possible hazard due to insulation failure.

All electrical wiring must not touch the water piping or any moving parts of the fan motors.

Confirm that the unit has been switched OFF before installing or servicing the unit.

Risk of electric shock, can cause injury or death. Disconnect all remain electric power supplies before servicing.

DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in the fire hazards.

Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. {Depending on the type and source of the electrical waves, static may be heard even when more than 1m away}.

! CAUTION

Please take note of the following important points when installing.

Do not install the unit where leakage of flammable gas may occur.

If gas leaks and accumulates around the unit, it may cause fire ignition.

Ensure that drainage piping is connected properly.

If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture.

Do not overcharge the unit.

This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor.

Ensure that the unit’s panel is closed after service or installation.

Unsecured panels will cause the unit to operate noisily.

Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.

Before turning off the power supply set the remote controller’sON/OFFswitchtothe“OFF”positiontoprevent the nuisance tripping of the unit. If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.

Do not install the units at or near doorway.

Do not operate any heating apparatus too close to the air conditionerunit oruse in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction.

When the unit is used in kitchen, keep flour away from going into suction of the unit.

This unit is not suitable for factory used where cutting oil mist or iron powder exist or voltage fluctuates greatly.

Do not install the units at area like hot spring or oil refinery plant where sulphide gas exists.

Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.

IMPORTANT : DO NOT INSTALLOR USE THEAIR CONDITIONER UNIT IN A LAUNDRY ROOM.

Don’t use joined and twisted wires for incoming power supply.

The equipment is not intended for use in a potentially explosive atmosphere.

NOTICE

Disposal requirement

Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.

Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation.

Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information.

Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.

<![if ! IE]>

<![endif]>English

3

Daikin FTS20JEV1K, RS20JEV1K, FTS25JEV1K, RS25JEV1K Installation manuals

INSTALLATION DIAGRAM

Indoor unit

Caulk pipe

Cut thermal insulation pipe to

30mm or more from ceiling

hole gap

an appropriate length and wrap

 

 

with putty.

it with tape, making sure that

Front panel

 

no gap is left in the insulation

 

pipe’s cut line.

 

 

50mm or more from walls

 

Wrap the insulation pipe with the

(on both sides)

 

finishing tape from bottom to top.

M4 x 12L

Service lid

Air filter

Opening service lid

 

Service lid is opening/

 

closing type.

 

Opening method

 

1) Remove the service lid

 

screws.

 

 

2) Pull out the service lid

 

 

diagonally down in the

Titanium apatite photocatalytic

direction of the arrow.

3) Pull down.

air-purifying filter (2)

 

 

 

Titanium apatite photocatalytic

 

air-purifying filter

Air filter

 

 

 

Filter frame

 

 

Tab

 

 

Outdoor Unit

250mm

from wall

 

INSTALLATION OF THE OUTDOOR UNIT

The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to the smooth air flow. Please follow the installation clearances shown in the figure. Select the coolest possible place where intake air temperature is not greater than the outside air temperature (please refer operating range).

Installation clearances

Dimension

A

B

C

D

 

 

 

 

 

Minimum Distance,

300

1000

300

500

mm (in)

(11.8)

(39.4)

(11.8)

(19.7)

Note: If there is any obstacle higher than 2m, or if there is any obstruction at the upper part of the unit, please allow more space than the figure indicated in the above table.

 

 

A

B

 

 

 

<![if ! IE]>

<![endif]>Obstacle

<![if ! IE]>

<![endif]>Return air

<![if ! IE]>

<![endif]>Discharge air

<![if ! IE]>

<![endif]>Obstacle

 

 

C

 

 

D

 

<![if ! IE]>

<![endif]>Obstacle

<![if ! IE]>

<![endif]>Return air

 

 

<![if ! IE]>

<![endif]>Service access

<![if ! IE]>

<![endif]>Obstacle

4

Loading...