DAIKIN FTX30NVJU, FTX36NVJU User Manual

0 (0)

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

Enjoy year-roun d comfort.

MODELS

FTX30NVJU

FTX36NVJU

Español Français English

DAIKIN FTX30NVJU, FTX36NVJU User Manual

Features

Enhanced comfort and energy savings

INTELLIGENT EYE

The INTELLIGENT EYE sensor detects human movement in a room. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.

Page 15

WEEKLY TIMER

Up to 4 timer settings can be saved for each day of the week according to your family’s life style.The WEEKLY TIMER allows you to set on/off times and the desired temperature. Page 21

Other functions

COMFORT AIRFLOW

OUTDOOR UNIT QUIET

The airfl ow direction is upward while in COOL and DRY operation, and downward while in HEAT operation.This function prevents cold or warm air from blowing directly on your body. Page 15

OUTDOOR UNIT QUIET operation assures a low noise level of the outdoor unit.This function is useful to maintain a quiet neighborhood.

Page 18

1

ECONO

This function enables effi cient operation by limiting the maximum power consumption. It is useful when using the air conditioner and other electrical devices simultaneously on a shared electrical circuit. Page 18

Contents

 

Read Before Operation

 

Safety Considerations.....................................

3

Names of Parts...............................................

5

Preparation Before Operation.........................

9

Basic Operation

 

AUTO · DRY · COOL · HEAT · FAN

 

Operation...........................................

11

Adjusting the Airflow Rate..................

13

Adjusting the Airflow Direction...........

14

Useful Functions

 

COMFORT AIRFLOW /

 

INTELLIGENT EYE Operation...........

15

POWERFUL Operation......................

17

ECONO / OUTDOOR UNIT QUIET

 

Operation...........................................

18

TIMER Operation

 

ON/OFF TIMER Operation ................

19

WEEKLY TIMER Operation................

21

Care

 

Care and Cleaning.......................................

27

When the Need Arises

 

FAQ..............................................................

32

Troubleshooting ...........................................

33

English

2

Read Before Operation

Safety Considerations

Read these Safety Considerations for Operations carefully before operating an air conditioner or heat pump.

Make sure that the unit operates properly during the startup operation. Instruct the user on how to operate and maintain the unit.

Inform users that they should store this operation manual with the installation manual for future reference. Meanings of DANGER, WARNING, CAUTION, and NOTE

Symbols:

DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.

NOTE Indicates situations that may result in equipment or property-damage accidents only.

DANGER

Do not install the unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death.

Any abnormalities in the operation of the air conditioner or heat pump, such as smoke or fire, could result in severe injury or death.Turn off the power and contact your dealer immediately.

Refrigerant gas may produce toxic gas if it comes into contact with fire, such as from a fan heater, stove, or cooking device. Exposure to this gas could cause severe injury or death.

For refrigerant leakage, consult your dealer. Refrigerant gas is heavier than air and replaces oxygen.

A massive leak could lead to oxygen depletion, especially in basements, and an asphyxiation hazard could occur leading to serious injury or death.

If equipment utilizing a burner is used in the same room as the air conditioner or heat pump, there is the danger of oxygen deficiency which could lead to an asphyxiation hazard resulting in serious injury or death. Be sure to ventilate the room sufficiently to avoid this hazard.

Safely dispose of the packing materials. Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries.

Tear apart and throw away plastic packaging bags so that children will not play with them. Children playing with plastic bags face the danger of death by suffocation.

WARNING

Contact your dealer for repair and maintenance. Improper repair and maintenance may result in water leakage, electric shock, and fire. Only use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a professional.

Contact your dealer to move and reinstall the air conditioner or heat pump. Incomplete installation may result in water leakage, electric shock, and fire.

Never let the indoor unit or the remote controller get wet. Water can cause an electric shock or a fire.

Never use flammable spray such as hair spray, lacquer, or paint near the unit. Flammable spray may cause a fire.

When a fuse blows out, never replace it with one of incorrect ampere ratings or different wires. Always replace any blown fuse with a fuse of the same specification.

Never remove the fan guard of the unit. A fan rotating at high speed without the fan guard is very dangerous.

Never inspect or service the unit by yourself. Contact a qualified service person to perform this work.

Turn off all electrical power before doing any maintenance to avoid the risk of serious electric shock; never sprinkle or spill water or liquids on the unit.

Do not touch the switch with wet fingers.Touching a switch with wet fingers can cause electric shock.

Do not allow children to play on or around the unit to prevent injury.

The heat exchanger fins are sharp enough to cut.To avoid injury wear gloves or cover the fins while working around them.

Do not put a finger or other objects into the air inlet or air

outlet.The fan is rotating at high speed and will cause injury.

Check the unit foundation for damage on a continuous basis, especially if it has been in use for a long time. If left in a damaged condition the unit may fall and cause injury.

Placing a flower vase or other containers with water or other liquids on the unit could cause a shock or fire if a spill occurs.

Do not touch the air outlet or horizontal blades while the swing flap is in operation because fingers could get caught and injured.

Never touch the internal parts of the controller. Do not remove the front panel because some parts inside are dangerous to touch.To check and adjust internal parts, contact your dealer.

CAUTION

Do not use the air conditioner or heat pump for any other purposes other than comfort cooling or heating.

Do not use the unit for cooling precision instruments, food, plants, animals or works of art.

3

Read Before Operation

English

Do not place items under the indoor unit as they may be damaged by condensates that may form if the humidity is above 80% or if the drain outlet gets blocked.

Before cleaning, stop the operation of the unit by turning the power off or by pulling the supply cord out from its receptacle. Otherwise, an electric shock and injury may result.

Do not wash the air conditioner or heat pump with excessive water. An electric shock or fire may result.

Avoid placing the controller in a spot splashed with water. Water entering the controller may cause an electric shock or damage the internal electronic parts.

Do not operate the air conditioner or heat pump when using a room-fumigation type of insecticide.

Failure to observe this could cause the chemicals to be deposited in the unit and can endanger the health of those who are hypersensitive to chemicals.

Do not turn off the power immediately after stopping operation. Always wait for at least 5 minutes before turning off the power. Otherwise, water leakage may occur.

The appliance is not intended for use by young children or infirm persons without supervision.

The remote controller should be kept away from children so they cannot play with it.

Consult with the installation contractor for cleaning.

Incorrect cleaning of the inside of the air conditioner or heat pump could make the plastics parts break and cause water leakage or electric shock.

Do not touch the air inlet or aluminum fin of the air conditioner or heat pump as they can cut and cause injury.

Do not place objects in direct proximity of the outdoor unit. Do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside the unit, animals can cause the unit to malfunction, and cause smoke or fire when they make contact with electrical parts.

NOTE

Never press the button of the remote controller with a hard, pointed object.The remote controller may be damaged.

Never pull or twist the electric wire of the remote controller. It may cause the unit to malfunction.

Do not place appliances that produce open flames in places that are exposed to the airflow of the unit or under the indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat.

Do not expose the controller to direct sunlight.The LCD display can become discolored and may fail to display the data.

Do not wipe the controller operation panel with benzene, thinner, chemical dust cloth, etc.The panel may get discolored or the coating can peel off. If it is heavily dirty, soak a cloth in water-diluted neutral detergent, squeeze it well and wipe the panel clean.Then wipe it with another dry cloth.

Dismantling of the unit, disposal of the refrigerant, oil, and additional parts, should be done in accordance with the relevant local, state, and national regulations.

Operate the air conditioner or heat pump in a sufficiently ventilated area and not surrounded by obstacles. Do not use the air conditioner or heat pump in the following places.

a.Places with a mist of mineral oil, such as cutting oil.

b.Locations such as coastal areas where there is a lot of salt in the air.

c.Locations such as hot springs where there is a lot of sulfur in the air.

d.Locations such as factories where the power voltage varies a lot.

e.In cars, boats, and other vehicles.

f.Locations such as kitchens where oil may splatter or where there is steam in the air.

g.Locations where equipment produces electromagnetic waves.

h.Places with an acid or alkaline mist.

i.Places where fallen leaves can accumulate or where weeds can grow.

Take snow protection measures. Contact your dealer for the details of snow protection measures, such as the use of a snow protection hood.

Do not attempt to do electrical work or grounding work unless you are licensed to do so. Consult with your dealer for electrical work and grounding work.

Pay attention to operating sound. Be sure to use the following places:

a.Places that can sufficiently withstand the weight of the air conditioner or heat pump yet can suppress the operating sound and vibration.

b.Places where warm air from the air outlet of the outdoor unit or the operating sound of the outdoor unit does not annoy neighbors.

Make sure that there are no obstacles close to the outdoor unit. Obstacles close to the outdoor unit may drop the performance of the outdoor unit or increase the operating sound of the outdoor unit.

Consult your dealer if the air conditioner or heat pump in operation generates unusual noise.

Make sure that the drainpipe is installed properly to drain water. If no water is discharged from the drainpipe while the air conditioner or heat pump is in the cooling mode, the drainpipe may be clogged with dust or dirt and water leakage from the indoor unit may occur. Stop operating the air conditioner or heat pump and contact your dealer.

FTP001-U

4

Read Before Operation

Names of Parts

Indoor Unit

Front panel

Air outlet Model name

Louvers (vertical blades)

• The louvers are inside of the air outlet. Page 14

Flaps (horizontal blades)

Page 14

Air inlet

Panel tab

INTELLIGENT EYE sensor

Detects the movements of people and automatically switches between normal operation and energy saving operation. Page 15,16

Indoor temperature sensor

Detects the air temperature around the unit.

Display

Signal receiver

 

 

OPERATION lamp (green)

 

 

 

 

 

• Receives signals from the remote

TIMER lamp (orange)

controller.

 

• When the unit receives a signal, you

 

Page 19,20,23

will hear a beep sound.

 

 

Case

Sound type

INTELLIGENT EYE lamp

Operation start

beep-beep

(green)

Page 15

Setting changed

beep

 

 

Operation stop

long beep

 

 

Indoor unit ON/OFF switch

Press this switch once to start operation. Press once again to stop it.

For the operation mode setting, refer to the following table.

Model

Mode

Temperature setting

Airfl ow rate

 

 

 

 

HEAT PUMP

AUTO

77°F (25°C)

AUTO

 

 

 

 

COOLING ONLY

COOL

72°F (22°C)

AUTO

 

 

 

 

• This switch can be used when the remote controller is missing.

5

 

Read Before Operation

 

English

Open the front panel

 

 

Air fi lter

 

Titanium apatite

 

photocatalytic

 

air-purifying fi lter

Outdoor Unit

 

Air inlet

Outdoor temperature

(back and side)

sensor (back)

 

Inter-unit wire

 

Ground terminals

Air outlet

(inside)

 

 

Refrigerant pipes

 

Drain hose

 

Model name

 

6

Read Before Operation

Names of Parts

Remote Controller

Signal transmitter

Receiver

To use the remote controller, aim the transmitter at the indoor unit. If there is anything blocking the signals between the unit and the remote controller, such as a curtain, the unit may not operate.

The maximum transmission distance is about 23ft (7m).

FAN setting button

• Selects the airfl ow rate setting.

Page 13

Display (LCD)

• Displays the current settings. (In this illustration, each section is

shown with all its displays on for the purpose of explanation.)

TEMPERATURE adjustment button

• Changes the temperature setting.

Page 12

ON/OFF button

• Press this button once to start operation.

Press once again to stop it. Page 11

POWERFUL button

• POWERFUL operation. Page 17

Front cover

• Open the front cover. Page 8

Model ARC466A37

7

Read Before Operation

English

Open the front cover

MODE selector button

Selects the operation mode. (AUTO/DRY/COOL/HEAT/ FAN) Page 11

COMFORT/SENSOR button

COMFORT AIRFLOW / INTELLIGENT EYE operation. Page 15

OFF TIMER button (NIGHT SET mode)

Page 20

TIMER CANCEL button

• Cancels the timer setting.

Page 19,20

Cannot be used for the WEEKLY TIMER operation.

SELECT button

Changes the clock, ON/OFF TIMER and WEEKLY TIMER settings.

ECONO/QUIET button

• ECONO/OUTDOOR UNIT QUIET operation. Page 18

SWING button

• Adjusts the airfl ow direction.

Page 14

: WEEKLY button

: PROGRAM button

: COPY button

: BACK button

: NEXT button

• WEEKLY TIMER operation.

Page 21

ON TIMER button

Page 19

CLOCK button Page 10

8

Read Before Operation

Preparation Before Operation

CAUTION

Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure Please observe the following precautions and use safely

If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately fl ush the eyes with tap water and seek the attention of a medical professional.

Keep batteries out of reach of children. In the event that batteries are swallowed, seek the immediate attention of a medical professional.

Do not expose batteries to heat or fi re. Do not disassemble or modify batteries.The insulation or gas release vent inside the battery may be damaged, resulting in battery leakage, rupturing, or heating.

Do not damage or peel off labels on the batteries.

2

Position + and

correctly!

3 1

Grip both sides of the front cover

Remote controller

Screws

Remote controller holder

To insert the batteries

1. Slide the front cover to take it off

2. Insert 2 dry batteries AAA.LR03 (alkaline).

3. Replace the front cover

To attach the remote controller holder to a wall

1. Choose a place where the signals reach the unit

2. Attach the holder to a wall, a pillar, or similar location with the screws supplied with the holder

3. Place the remote controller in the remote controller holder

Fahrenheit/Celsius display switch

Press and (TIMER button) simultaneously for about 5 seconds.

The temperature will be displayed in Celsius when it is presently displayed in Fahrenheit, and vice versa.

The switch operation is only possible when the temperature is being displayed.

NOTE

Notes on batteries

To avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time.

The standard replacement time is about 1 year. Both batteries should be replaced at the same time. Be sure to replace them with new size AAA. LR03 (alkaline) batteries.

However, if the remote controller display begins to fade and the possible transmission range becomes shorter within a year, replace both batteries as specifi ed above.

The batteries supplied with the remote controller are for initial operation.The batteries may run out in less than 1 year.

Note on remote controller

• Do not drop the remote controller. Do not get it wet.

9

Read Before Operation

English

Turn on the circuit breaker

After the power is turned on, the fl aps of the indoor unit open and close once to set the reference position.

To set the clock

1. Press

” is displayed on the LCD.

” and “ ” blink.

2. Press to set the current day of the week 3. Press

” blinks.

4. Press to set the clock to the present time

• Holding downorrapidly increases or decreases the displayed time.

5. Press

Point the remote controller at the indoor unit when pressing the buttons. ” blinks.

NOTE

Fahrenheit/Celsius display change function of remote controller

The set temperature may increase when the display is changed to Celsius from Fahrenheit, because a fraction of 0.5°C is rounded up.

Example: A set temperature of 65°F (equivalent to 18.5°C) will be converted into 19°C.

When the display is changed to Fahrenheit again, the set temperature will be converted into 66°F (equivalent to 19°C) instead of the original set temperature (65°F) but a set temperature of 66°F (equivalent to 19°C) will be converted into 19°C with no temperature change.

A reception sound will go off for the transmission of set temperature to the indoor unit at the time of setting the Fahrenheit/Celsius display change function.

Note on setting the clock

• If the indoor unit’s internal clock is not set to the correct time, the ON/OFF TIMER and WEEKLY TIMER will not operate punctually.

10

Basic Operation

AUTO · DRY · COOL · HEAT · FAN

Operation

The air conditioner operates with the operation mode of your choice.

From the next time on, the air conditioner will operate with the same operation mode.

To start operation

1. Press and select an operation mode

• Each pressing of the button changes the mode setting in sequence.

HEAT PUMP

 

 

 

 

 

model

AUTO

DRY

COOL

HEAT

FAN

COOLING ONLY

 

 

 

model

DRY

COOL

FAN

2. Press

• “ ” is displayed on the LCD.

• The OPERATION lamp lights green.

Display

To stop operation

Press again

” disappears from the LCD.

The OPERATION lamp goes off.

NOTE

Notes on AUTO operation

In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the indoor temperature and starts the operation.

The system automatically reselects setting at a regular interval to bring the indoor temperature to the user-setting level.

Note on DRY operation

Eliminates humidity while maintaining the indoor temperature as much as possible. It automatically controls temperature and airfl ow rate, so manual adjustment of these functions is unavailable.

11

Loading...
+ 26 hidden pages