Beckhoff CP7709, CP7701, CP7703, CP7702, CP7719 Installation And Operating Instructions Manual

...
0 (0)
Installation and Operating instructions for
Panel PC CP77xx
Version: 2.1 Date: 2009-07-07
General Notes
Table of contents
1.
2.
3.
4.
5.
6.
General Notes 2
Notes on the documentation 2 Liability conditions 2 Description of safety symbols 2 Basic safety measures 3 Operator’s obligation to exercise diligence 4 Operator requirements 4 UL-Certificate of Compilance 4
Product Description 5
Appropriate Use 5 Connections 5
Pin assignment 5
Connector description 6
Serial interface 6 Power supply 6 Network interfaces 6 Protective Earthing 6
Connecting cables 6
RS 232-adapter cable 6 Ethernet patch cable and network connectors, optional 6
Installation Instructions 7
Transport and Unpacking 7
Transport 7 Unpacking 7
Assembly 8
Assembly dimensions 8
Connecting the Panel PC 9
Connecting cables 9 Protective Earthing 9
Operating Instructions 10
Switching the Panel PC on and off 10 Operation 10 Keyboard codes 10 Compact Flash memory card 12 Servicing and maintenance 13
Cleaning the Panel PC 13 Servicing 13 Replacement of the Battery 13 Replacing the fluorescent lamps in the display 13 Lamp sets 14
Emergency procedures 14 Shutting down 14
Disposal 14
Troubleshooting 15
Fault correction 15 Beckhoff Support & Service 16
Beckhoff branches and partner companies 16 Beckhoff Headquarters 16 Beckhoff Support 16 Beckhoff Service 16
Appendix 17
Technical data 17 Approvals 17
FCC: Federal Communications Commission Radio Frequency Interference Statement 17 FCC: Canadian Notice 17
CP77xx 1
General Notes
General Notes
Notes on the documentation
This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components.
Liability conditions
The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
The documentation has been prepared with care. The products described are, however, constantly under development. For this reason, the documentation may not always be have been fully checked for consistency with the performance data, standards or other characteristics described. None of the statements in this manual represent a guarantee for as set out in § 443 of the German Civil Code or a statement about the assumed use according to the contract as set out in § 434 para. 1 clause 1 no. 1 of the German Civil Code. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation.
© This documentation is protected by copyright. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden.
Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
Danger
This symbol is intended to highlight risks for the life or health of personnel.
Warning
This symbol is intended to highlight risks for equipment, materials or the environment.
i
Note
This symbol indicates information that contributes to better understanding.
2 CP77xx
General Notes
Basic safety measures
Only switch the PC off after closing the software
Before the Panel PC is switched off, software that is running must be properly closed.
Otherwise it is possible that data on the hard disk is lost. Please read the section Switching the Panel PC on and off.
Warning
Before opening the housing, and whenever the Panel PC is not being used for control purposes (such as during functional checks after a repair), all parts of the equipment must first be switched off, after which the Panel PC is to be disconnected from the equipment.
Disconnect the device by unplugging the connectors on the rear side of the Panel PC.
Items of equipment that have been switched off must be secured against being switched on again.
Danger
Displays used for the Panel PC’s LC-display are operated with a voltage of up to 1000 V, depending on type. For that reason:
The supply voltage must be disconnected before the housing of the Panel PC is opened!
i
Note
Assembly work on the Panel PC during operation may damage the device:
if metal objects such as screws or tools fall onto operating circuit boards.
if connecting cables internal to the Panel PC are removed or inserted during operation.
CP77xx 3
General Notes
Operator’s obligation to exercise diligence
The operator must ensure that
the Industrial PC is only used for its intended purpose (see Product
Description section);
the Industrial PC is only operated in a sound condition and in working order;
the instruction manual is in good condition and complete, and always available for reference at the place of installation of the Industrial PC;
the Industrial PC is operated, maintained and repaired only by suitably qualified and authorized personnel.
the personnel is instructed regularly about relevant occupational safety and environmental protection aspects, and is familiar with the operating manual and in particular the safety notes contained herein.
none of the safety and warning notes attached to the Industrial PC are removed, and all notes remain legible.
National regulations depending on the machine type
Depending on the type of machine and plant in which the Industrial PC is used, national regulations governing the controllers of such machines will apply, and must be observed by the operator. These regulations cover, amongst other things, the intervals between inspections of the controller.
The operator must initiate such inspections in good time.
Warning
Only trained persons may open the Industrial PC housing!
The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC.
Procedure in the event of a fault
In the event of faults at the Industrial PC, the list in the section Fault
correction can be used to determine the measures to be taken.
Operator requirements
Read the operating instructions
Anyone who uses the Industrial PC must have read these operating instructions.
Software knowledge
Every user must be familiar with all the functions of the software installed on the Industrial PC to which he has access.
UL-Certificate of Compilance
We herewith confirm that the Panel PC CP77xx of Beckhoff Automation GmbH meets the requirements of the Underwriters Laboratories Inc.
®
(UL)-
standard:
Certificate Number: 280607 – E220403 Report Reference: E220403, April 16th, 2007 Issue Date: 2007 June 28
Standards for Safety
The correspondance of the mentioned product with these requirements is proved by the fact that this product meets with the following single standards:
UL 60950-1, 1st Edition, 2006-07-07 (Information Technology Equipment – Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
4 CP77xx
Loading...
+ 13 hidden pages