SEMICONDUCTOR TECHNICAL DATA
Universal Hexadecimal |
MC10H136 |
|
Counter |
||
|
||
|
|
The MC10H136 is a high speed synchronous hexadecimal counter. This 10H part is a functional/pinout duplication of the standard MECL 10K family part, with 100% improvement in counting frequency and no increase in power-supply current.
• |
Counting Frequency, 250 MHz Minimum |
• |
Voltage Compensated |
• |
Power Dissipation, 625 mW Typical |
• |
MECL 10K-Compatible |
•Improved Noise Margin 150 mV
(Over Operating Voltage and Temperature Range)
L SUFFIX
CERAMIC PACKAGE
CASE 620±10
P SUFFIX
PLASTIC PACKAGE
CASE 648±08
FN SUFFIX
PLCC
CASE 775±02
MAXIMUM RATINGS
Characteristic |
Symbol |
Rating |
Unit |
|
|
|
|
Power Supply (VCC = 0) |
VEE |
±8.0 to 0 |
Vdc |
Input Voltage (VCC = 0) |
VI |
0 to VEE |
Vdc |
Output Current Ð Continuous |
Iout |
50 |
mA |
Ð Surge |
|
100 |
|
|
|
|
|
Operating Temperature Range |
TA |
0 to +75 |
°C |
Storage Temperature Range Ð Plastic |
Tstg |
±55 to +150 |
°C |
Ð Ceramic |
|
±55 to +165 |
°C |
ELECTRICAL CHARACTERISTICS (VEE = ±5.2 V ±5%) (See Note)
|
|
|
0° |
25° |
|
75° |
|
|||
|
|
|
|
|
|
|
|
|
|
|
Characteristic |
Symbol |
Min |
|
Max |
Min |
Max |
Min |
|
Max |
Unit |
|
|
|
|
|
|
|
|
|
|
|
Power Supply Current |
IE |
Ð |
|
165 |
Ð |
150 |
Ð |
|
165 |
mA |
Input Current High |
IinH |
|
|
|
|
|
|
|
|
μA |
Pins 5, 6, 11, 12, 13 |
|
Ð |
|
430 |
Ð |
275 |
Ð |
|
275 |
|
Pin 9 |
|
Ð |
|
670 |
Ð |
420 |
Ð |
|
420 |
|
Pin 7 |
|
Ð |
|
535 |
Ð |
335 |
Ð |
|
335 |
|
Pin 10 |
|
Ð |
|
380 |
Ð |
240 |
Ð |
|
240 |
|
|
|
|
|
|
|
|
|
|
|
|
Input Current Low |
IinL |
0.5 |
|
Ð |
0.5 |
Ð |
0.3 |
|
Ð |
μA |
High Output Voltage |
VOH |
±1.02 |
|
±0.84 |
±0.98 |
±0.81 |
±0.92 |
|
±0.735 |
Vdc |
Low Output Voltage |
VOL |
±1.95 |
|
±1.63 |
±1.95 |
±1.63 |
±1.95 |
|
±1.60 |
Vdc |
High Input Voltage |
VIH |
±1.17 |
|
±0.84 |
±1.13 |
±0.81 |
±1.07 |
|
±0.735 |
Vdc |
Low Input Voltage |
VIL |
±1.95 |
|
±1.48 |
±1.95 |
±1.48 |
±1.95 |
|
±1.45 |
Vdc |
AC PARAMETERS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Propagation Delay |
tpd |
|
|
|
|
|
|
|
|
ns |
Clock to Q |
|
0.7 |
|
2.3 |
0.7 |
2.4 |
0.7 |
|
2.5 |
|
Clock to Carry Out |
|
1.0 |
|
4.8 |
1.0 |
4.9 |
1.0 |
|
5.0 |
|
Carry in to Carry |
|
|
|
|
|
|
|
|
|
|
Out |
|
0.7 |
|
2.5 |
0.7 |
2.6 |
0.7 |
|
2.7 |
|
|
|
|
|
|
|
|
|
|
|
|
Set-up Time |
tset |
|
|
|
|
|
|
|
|
ns |
Data (D0 to C) |
|
2.0 |
|
Ð |
2.0 |
Ð |
2.0 |
|
Ð |
|
Select (S to C) |
|
3.5 |
|
Ð |
3.5 |
Ð |
3.5 |
|
Ð |
|
Carry In (Cin to C) |
|
2.0 |
|
Ð |
2.0 |
Ð |
2.0 |
|
Ð |
|
(C to Cin) |
|
0 |
|
Ð |
0 |
Ð |
0 |
|
Ð |
|
Hold Time |
thold |
|
|
|
|
|
|
|
|
ns |
Data (C to D0) |
|
0 |
|
Ð |
0 |
Ð |
0 |
|
Ð |
|
Select (C to S) |
|
±0.5 |
|
Ð |
±0.5 |
Ð |
±0.5 |
|
Ð |
|
Carry In (C to Cin) |
|
0 |
|
Ð |
0 |
Ð |
0 |
|
Ð |
|
(Cin to C) |
|
2.2 |
|
Ð |
2.2 |
Ð |
2.2 |
|
Ð |
|
Counting Frequency |
fcount |
250 |
|
Ð |
250 |
Ð |
250 |
|
Ð |
MHz |
Rise Time |
tr |
0.5 |
|
2.3 |
0.5 |
2.4 |
0.5 |
|
2.5 |
ns |
Fall Time |
tf |
0.5 |
|
2.3 |
0.5 |
2.4 |
0.5 |
|
2.5 |
ns |
NOTE:
FUNCTION SELECT TABLE
CIN |
S1 |
S2 |
Operating Mode |
X |
L |
L |
Preset (Program) |
L |
L |
H |
Increment (Count Up) |
H |
L |
H |
Hold Count |
L |
H |
L |
Decrement (Count Down) |
H |
H |
L |
Hold Count |
X |
H |
H |
Hold (Stop Count) |
SEQUENTIAL TRUTH TABLE *
|
|
|
INPUTS |
|
|
OUTPUTS |
||||||||||||
S1 |
S2 |
D0 |
D1 |
D2 |
D3 |
Carry |
Clock |
Q0 |
Q1 |
Q2 |
Q3 |
|
|
Carry |
|
|
||
|
|
|
* * |
|
|
|
|
|
||||||||||
|
|
|
|
|
|
In |
Out |
|||||||||||
L |
L |
L |
L |
H |
H |
|
X |
H |
L |
L |
H |
H |
L |
|||||
L |
H |
X |
X |
X |
X |
|
L |
H |
H |
L |
H |
H |
H |
|||||
L |
H |
X |
X |
X |
X |
|
L |
H |
L |
H |
H |
H |
H |
|||||
L |
H |
X |
X |
X |
X |
|
L |
H |
H |
H |
H |
H |
L |
|||||
L |
H |
X |
X |
X |
X |
|
H |
L |
H |
H |
H |
H |
H |
|||||
L |
H |
X |
X |
X |
X |
|
H |
H |
H |
H |
H |
H |
H |
|||||
H |
H |
X |
X |
X |
X |
|
X |
H |
H |
H |
H |
H |
H |
|||||
L |
L |
H |
H |
L |
L |
|
X |
H |
H |
H |
L |
L |
L |
|||||
H |
L |
X |
X |
X |
X |
|
L |
H |
L |
H |
L |
L |
H |
|||||
H |
L |
X |
X |
X |
X |
|
L |
H |
H |
L |
L |
L |
H |
|||||
H |
L |
X |
X |
X |
X |
|
L |
H |
L |
L |
L |
L |
L |
|||||
H |
L |
X |
X |
X |
X |
|
L |
H |
H |
H |
H |
H |
H |
*Truth table shows logic states assuming inputs vary in sequence shown from top to bottom.
**A clock H is defined as a clock input transition from a low to a high logic level.
DIP PIN ASSIGNMENT
VCC1 |
|
1 |
|
16 |
|
|
VCC2 |
||
|
|
|
|
||||||
|
2 |
|
15 |
|
|||||
Q2 |
|
|
|
|
Q1 |
||||
Q3 |
|
3 |
|
14 |
|
|
Q0 |
||
|
|
|
|||||||
|
|
|
4 |
|
13 |
|
|
CLOCK |
|
COUT |
|
|
|
|
|||||
|
|
|
|||||||
|
5 |
|
12 |
|
|
D0 |
|||
D3 |
|
|
|
|
|||||
D2 |
|
6 |
|
11 |
|
|
D1 |
||
|
|
|
|||||||
|
|
|
7 |
|
10 |
|
|
|
|
S2 |
|
|
|
|
CIN |
||||
|
|
|
|||||||
|
|
|
8 |
|
9 |
|
|||
VEE |
|
|
|
|
S1 |
||||
|
|
|
|
|
|
|
|
Pin assignment is for Dual±in±Line Package. For PLCC pin assignment, see the Pin Conversion Tables on page 6±11 of the Motorola MECL Data Book (DL122/D).
Each MECL 10H series circuit has been designed to meet the dc specifications shown in the test table, after thermal equilibrium has been established. The circuit is in a test socket or mounted on a printed circuit board and transverse air flow greater than 500 Iinear fpm is maintained. Outputs are terminated through a 50-ohm resistor to ±2.0 volts.
9/96
Motorola, Inc. 1996 |
2±1 |
REV 6 |
MC10H136
LOGIC DIAGRAM
S1 9
S2 |
7 |
|
|
|
|
|
|
|
|
|
|
|
Carry In |
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Q0 |
|
T |
Q1 |
|
T |
Q2 |
|
T |
Q3 |
|
|
T |
|
|
|
|
|
T |
|
|
T |
|
|
|
|
|
|
|
|
|
|
T |
|
|
||
|
|
Q0 |
|
T |
Q1 |
|
T |
Q2 |
|
Q3 |
|
|
|
T |
C |
|
T |
C |
|
|
T C |
|
T T C |
|
|
Clock |
|
|
|
|
|
|
|
|
|
|
|
|
|
13 |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
|
14 |
11 |
|
15 |
6 |
|
2 |
5 |
3 |
4 |
|
D0 |
|
Q0 |
D1 |
|
Q1 |
D2 |
|
Q2 |
D3 |
Q3 |
Carry Out |
VCC1 = Pin 1
VCC2 = Pin 16
VEE = Pin 8
NOTE: FLIP-FLOPS WILL TOGGLE WHEN ALL T INPUTS ARE LOW.
APPLICATION INFORMATION
The MC10H136 is a high speed synchronous counter that operates at 250 MHz. Counter operating modes include count up, count down, pre-set and hold count. This device allows the designer to use one basic counter for many applications.
The S1, S2, control lines determine the operating modes of the counter. In the pre-set mode, a clock pulse is necessary to load the counter with the information present on the data inputs (D0, D1, D2, and D3). Carry out goes low on the terminal count or when the counter is being pre-set.