458GB
High-accuracy Digital Contact Sensor
GT2-70 Series Setting Guid
Names of the part of the amplifier
Digital LED display |
Special output indicator |
Status indicator |
Arrow buttons |
Detection level |
|
indicator |
|
[PRESET] |
|
button |
|
Preset indicator |
|
Bank indicator Bar LEDs |
Timing input |
[SET] button |
High position indicator/ |
indicator |
[MODE] button |
Low position indicator |
PV indicator |
Digital LED Display
The main display can be switched by pressing the left/right arrow buttons.
1. P.V. value display |
8. Preset value setup display |
2. Calculated value display*1 |
7. LL setting value display |
3. R.V. value display |
while using 5-output function*2 |
|
|
4. HH setting value display |
6. LOW setting value display |
while using 5-output function*2 |
5. HIGH setting value display
P.V. : Displays a value used for output judgment. Calc : Displays a calculated value when used. R.V. : Displays the raw, actual detection value. HH : Displays the HH setting value when used HI : Displays the HIGH setting value.
LOW : Displays the LOW setting value.
LL : Displays the LL setting value when used.
PRESET : Displays the value which would be set when the [PRESET] button is pressed.
Set the current value to “0”
1. Set the master target which should be “0”.
Master workpiece
2.Press the [PRESET] button.
3.The current value would be set to “0”.
Set the HIGH and LO tolerance.
1.Press the left/right arrow buttons until the [HIGH]/[LO] setting display appears.
HIGH setting value display |
LOW setting value display |
2.Input the HIGH or LO tolerance by pressing the up/down arrow buttons.
3.The HIGH and LO tolerance would be set.
Setting the Key Lock
1. Press the MODE and the up arrow button for at least 2 seconds.
Keylock display
2. The Key Lock display would appear.
Canceling the Key Lock
1.When the Key Lock is set, press the MODE and the up arrow button for at least 2 seconds.
Keylock cancel display
2. The Key Lock would be cancelled.
Initializing the sensor
1.Press the SET button 5 times while pressing the MODE button.
2.“rSt.no” would appear, press the up/down arrow button and select “rSt.YES”.
3.Press the MODE button. The sensor would be initialized.
1