Keyence FS-V22X, FS-V22, FS-V22G, FS-V22RP, FS-V22R Manual

4 (1)
Keyence FS-V22X, FS-V22, FS-V22G, FS-V22RP, FS-V22R Manual

96M0747???

DUAL DIGITAL FIBER

SENSOR

FS-V22/22G/22R(P)/22X

Instruction Manual

3. Amplifier Expansion

Up to 16 sub units can be connected to each main unit.

1) Remove the expansion protective cover from the main unit.

2) Mount each amplifier to the DIN rail.

3) Press the two claws of each sub unit to the grooves on the main unit until

the claws snap. 4) Mount the end units to the leftand right-hand sides of the whole amplifi-

ers in the method shown in the figure at step 2.

5) Check that the amplifiers are securely sandwiched by the end units. Use a Phillips screwdriver and securely tighten the screws on the

end units (i.e., two screws on each end unit).

1.Safety Precautions

WARNING

This product is used to detect targets. Do not apply the product to safety circuits for human protection.

This product is not of explosion-proof construction. Do not use the products in places with flammable gas, liquid, or dust.

This product is a sensor of DC power supply type. Do not apply AC power. The product may explode or burn if 100 VAC or a higher voltage is applied.

Check that all the accessories are ready before use.

• Accessories

 

 

Instruction

End units (x2)

Expansion Sticker (x1)

manual (x1)

 

 

 

 

Slide the unit to the

 

 

right to remove it.

4. Connecting Fiber Unit

1)

Open the dust cover in the direction

 

shown by arrow .

2)

Move down the fiber lock lever in the

 

direction shown by arrow .

3)

Insert a fiber unit into the fiber inser-

 

tion holes to a length of the fiber in-

 

sertion sign (i.e., approximately 14

 

mm).

Fiber insertion sign 4)

Move up and return the fiber lock lever

 

in the direction shown by arrow .

Note:If a thin fiber unit is used, an adapter provided with the thin fiber unit will be required.

Unless the right adapter is connected, the thin fiber unit will not detect targets correctly.

Cable outer dia.

Adapter

Appearance

ø1.3

Adapter A

 

ø1.0

Adapter B

 

To connect the coaxial reflective type fiber unit to the amplifier, connect the single-core fiber to the transmitter side, and connect the multiplecore fiber to the receiver side.

2. Part Names

Fiber lock lever

Transmitter

Single-core fiber

Multi-core fiber

Receiver

Operation indicator*

Set button

Digital

Preset value (PV)

 

 

green indicator

monitor

 

 

 

Manual

Current value

 

 

 

 

button

(CV) red indicator

Expansion protective cover

Expansion connector Mode button

Output selector

Cable

Dust cover

To remove the amplifiers added, take the steps opposite to the mounting procedure.

Put the provided sticker close to the sensor.

Note • The FS-V22/22G/22R(P)/22X incorporates a mutual interference prevention function, thus allowing the close mounting of a number of fiber units in the following modes.

 

Power mode

FINE

TURBO

SUPER

ULTRA

 

TURBO

TURBO

 

 

 

 

 

Number of

4

8

8

8

 

units connected

 

 

 

 

 

 

 

 

 

 

 

5. I/O Cricuit

Refer to the following I/O circuit diagram when connecting the unit to pe-

ripheral devices.

 

FS-V22/22G/22R/22X

FS-V22RP

* The operation indicator of the FS-V22X (infrared model) will not be lit.

 

 

 

 

 

DC 12 to 24V

 

 

Photoelectric mainsensorcircuit

Overcurrent circuitprotection

Max. 100mA

 

Photoelectric mainsensorcircuit

Overcurrent circuitprotection

(Control output)

 

Load

DC 5 to 40V

 

 

Black

(Control output)

 

 

Black

Max. 100mA

 

 

 

 

 

 

 

Load

DC 5 to 40V

 

0 V

 

 

 

 

 

 

1

6.Making Sensitivity Settings

Full Auto Calibration

In this mode, the PV will be set to the mean value of the maximum and minimum incident values obtained within a certain period.

Use this mode to detect moving workpieces.

1)Press the set button for a minimum of three seconds while the target workpiece is passing the sensing area of the fiber unit.

While the set button is pressed, the sensitivity of the sensor will be set according to the incident values.

Workpiece

The display will 3 s min. flash when the

settings are completed.

When the setting is finished, the digital monitor will display the PV in green.

PV (green)

CV (red)

Two-point Calibration

In this mode, the PV used will be the mean value of two sensing values obtained with and without a workpiece.

1)Press the set button for a moment without the workpiece in the sensing area (i.e., in front of the fiber unit).

Workpiece

The display will be lit when the workpiece is detected.

2)Locate the workpiece in the sensing area (i.e., in front of the fiber unit). Then press the set button for a moment.

Workpiece The PV will appear when

the settings are completed.

* If there is extremely little difference in sensitivity between the sensing values, the display will flash on completion of tuning.

Maximum Sensitivity Setting

If the sensing performance of the sensor drops due to dust or dirt, set the sensitivity of the sensor to maximum.

1)Press the set button without a workpiece if the fiber unit is a reflective model. Press the set button with a workpiece if the fiber unit is a through-beam model. In both cases, press the set button for a minimum of three seconds.

“Reflective model”

“Through-beam model”

3 s min.

The display will flash for a moment when the setting is finished. Then the PV will be displayed.

* If the sensing distance is insufficient, make sensitivity settings in the sensor in two-point tuning mode.

Manua| Calibration

In this mode, make manual PV settings.

PV

The PV value decreases by pressing this side of the manual button.

Positioning Calibration

The PV value increases by pressing this side of the manual button.

In this mode, a workpiece will be detected when the front edge of the workpiece has reached a preset position.

1)Press the set button for a moment without the workpiece in the sensing area (i.e., in front of the fiber unit).

Workpiece

The display will be lit when the workpiece is detected.

2) Locate the front edge of the workpiece in the sensing area. Then press the set button for a minimum of three seconds.

Workpiece

 

Front edge

The display will flash

 

 

3 s min. for a moment when

 

the setting is

 

finished. Then the

 

PV will be displayed.

7. Selecting Output

Either light-ON mode or dark-ON mode is selectable.

Press the mode button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the manual button

The display indicates that

the sensor is in dark-ON

within five seconds after

mode. The CV will be

pressing the mode button .

displayed if no buttons are

 

 

 

 

 

operated for approximately

 

 

 

 

 

five seconds.

 

 

 

 

 

Take the same steps to set the sensor to light-ON mode again.

8.User-friendly Functions

Access Mode Selection

Two modes are available to the display of values and menu items.

EASY

Only basic functions are displayed.

 

FULL

All available functions are displayed.

 

 

 

Press 3 s min.

 

 

 

Select

EASY

Completion

FULL

 

of selection

Press 3 s min.

 

 

 

 

• The mode is set to EASY before shipping.

2