KEYENCE FS-N15CP User Manual

4.7 (3)
KEYENCE FS-N15CP User Manual

96M11796

FS-N10 Series Water-proof Type

FS-N15CN/FS-N15CP

Precautions for Use

For precautions concerning safe use, as well as regulations and standards, refer to the “FS-N10 Series Instruction Manual”.

Difference with the Standard Type

The Water resistant type FS-N15C and the FS-N11C (FS-N10 Series standard 1 output M8 connector main unit) differ in the following aspects.

Protective structure IP66 (IP65 when the Small-diameter fiber unit is used)

There is no expansion connection, expansion unit connection and interference prevention function is not supported

Interference prevention ( ), common key operation function ( ) is not operational

External appearance/dimensions and weight

Main unit/ cover material

There are two types of adapter for connecting a Fiber Unit (thin fiber unit) with a fiber cable with a diameter of ø1 or ø1.3, one of each type is included.

Installing the Fiber Unit

When installing the Small-diameter fiber unit, always use the water-resistant adapter included with the FS-N15C .

If the standard adapter included with the Fiber unit instead of the water-proof adapter included with the FS-N15C is used, the protective structure IP65 cannot be met.

Cable Diameter

Adapter

Shape

ø1.3

Water-proof Adapter A

 

(OP-87379)

Tip: Black

 

ø1.0

Water-proof Adapter B

Tip: Gray

(OP-87380)

 

*For selection of a fiber unit

The use of a fiber unit which specifies its IP is recommended.

In the case of a fiber unit covered with fluorine resin, please make sure that water does not come into the gap between fibers (black) and the fluorine resin.

Specifications

Type

 

1 output type

Cable/M8 connector

M8 connector *1

Model

NPN

FS-N15CN

PNP

FS-N15CP

 

Control output

 

1 output

External input

 

1 input

Light source LED

Red 4-element LED (wavelength 630 nm)

Response time

50 μs (HIGH SPEED)/250 μs(FINE)/500 μs(TURBO)/ 1 ms (SUPER)

/4 ms (ULTRA)/16 ms (MEGA)

 

 

Output toggle

 

Light-ON/Dark-ON toggle

Timer function

Timer OFF/OFF delay/ON delay/One-shot

 

NPN output

NPN open collector 24 V or less; maximum 100 mA or less,

Control

residual voltage 1 V or less

 

output

PNP output

PNP open collector 24 V or less; maximum 100 mA or less,

 

residual voltage 1 V or less

 

 

External input

 

Input time 2 ms (ON)/20 ms (OFF) or more,

 

when selecting External calibration 25 ms (ON/OFF) or more

 

 

Expansion units/

0 units (expansion not possible)/0 units (connection not possible)

Number of interference prevention units

 

Protection circuit

Protection against reverse power connection, Output overcurrent, and Output surge

 

Power voltage

12 to 24 V DC ± 10% ripple (P-P) 10% or less

 

 

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V) *2

 

NPN

Econ on (ALL): 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V) *2

Rating

 

Eco full: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

 

 

Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V) *2

 

PNP

Eco on (ALL): 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V) *2

 

 

Eco full: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)

 

Operating ambient

Incandescent lamp: 20,000 lx or less; sunlight: 30,000 or less

 

luminance

 

 

 

Operating ambient

-20°C to +55°C (no freezing)

 

temperature

Environmental

 

Operating ambient

35 to 85%RH (no condensation)

resistance

humidity

 

 

Vibration resistance

10 to 55 Hz compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axis

 

Shock resistance

500 m/s2, 3 times for each of X, Y, Z axis

 

Protective structure

IP66 *3 *4

Material

Case

Main unit: glass-reinforced PBT; Cover: Sulfonic resin

Adapter

Glass-reinforced PBT

 

Case Dimensions

H 31.0 mm × W 13.0 mm × L 94.0 mm

Weight

 

App. 30g

*1 Use a cable of 30 m or less.

*2 When the Power Mode is set to HIGH SPEED, power consumption of 100 mW (4.0 mA) will be added.

*3 About the protective structure when a small-diameter fiber unit (the diameter of the cable is ø1.3 or ø1.0) is used. IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/ 93/43/63/63T etc.) is used.

When any small-diameter fiber units except for the above are used, IP65 is applied. *4 In any of the following cases, the protective structure IP66/IP65 cannot be satisfied.

When the Fiber Unit and KEYENCE’s M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first. Then retighten it as much as 1/16-1/8 of a rotation with pliers.)

When the dust cover of the Sensor Amplifier is open

When there is debris in the dust cover

When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit.