KEYENCE N-UB User Manual

4 (1)

96M13453

Dedicated Communication Unit

USB Output Type

N-UB

Instruction Manual

DANGER

Failure to follow these instructions may lead to death or

serious injury.

 

 

 

WARNING

Failure to follow these instructions may lead to injury.

 

 

CAUTION

Failure to follow these instructions may lead to product

damage (product malfunction, etc.).

 

 

 

Note

Provides additional information on proper operation.

 

 

TIPS

Indicates useful information or information that aids

understanding of text descriptions.

 

 

 

For Safely Using the Product

General precautions

At startup and during operation, be sure to check that the functions and performance of the N-UB is operating properly.

We recommend that you take substantial safety measures to avoid any damage in the event a problem occurs.

If the N-UB is modified or used in any way other than described in the specifications, its function and performance cannot be guaranteed.

When the N-UB is used in combination with other instruments, the function and performance may be effected by operating conditions and the surrounding environment.

Do not use the N-UB for the purpose of protecting the human body.

The information contained in this manual is subject to change without notice.

Notice

When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative.

For use under circumstances or environments which are not described in the manual

For use with nuclear power control, railway, aircraft, vehicles, incinerators, medical equipment, entertainment equipment, safety devices etc.

For use in applications where death or serious property damage is possible and extensive safety precautions are required.

For properly using the product

Do not use the N-UB in an environment subject to flammable, explosive, or corrosive gases.

Be sure that all screws are tightened securely.

Use crimp contacts of the specified size for wiring.

The N-UB uses a 24 VDC power supply. Using a power supply outside this range or an AC power supply may cause product failure.

Do not disassemble or modify the N-UB.This may cause

CAUTION

product failure.

Locate the cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or malfunctions.

The N-UB is a precision instrument. If the unit is dropped or shock is applied, it may be damaged. Use caution when unpacking, carrying, and mounting.

Be sure to observe all warnings, cautions, and precautions specified in the manual.

Do not install the N-UB in the following locations:

Locations subject to direct sunlight

Locations where the surrounding air temperature is outside the range of 0 to +50°C or locations subject to condensation as the result of severe changes in temperature

Locations where the ambient humidity is outside the range of 35 to 85%RH.

Locations subject to corrosive or flammable gases

Locations subject to dust, salts, iron dust, or oil smoke

Locations subject to shock or vibration

Locations subject to exposure of water, oil, or chemicals

Locations where strong magnetic or electric fields are generated

Foreign Regulations and Standards

UL certification

The N-UB complies with the following UL/CSA standards and has obtained the UL/C-UL certification.

Applicable standard

UL508, UL60950-1

UL File No.

E207185, E167973

UL category

NRAQ/NRAQ7, NWGQ2/NWGQ8

Be sure to observe the following installation and environment conditions.

Pollution degree 2

Overvoltage category I

Caution - Do not connect directly to the branch circuit. This product must be supplied power by a suitable, approved isolated transformer or power supply not exceeding 200 VA max.

Attention - Ne raccordez pas l'unité directement au circuit de dérivation. Ce produit doit être alimenté par un transformateur adapté, isolé et approuvé ou une alimentation ne dépassant pas 200 VA.

FCC regulations

The N-UB complies with the following FCC EMI regulations.

FCC Part 15 Subpart B, Class B digital device

Canada IC (Industry Canada) regulations

The N-UB complies with the following IC EMI regulations.

ICES-003, Class B digital apparatus

CE marking

The N-UB complies with the following essential requirements of the EU Directive.

EMC Directive (2004/108/EC)

The following harmonized standards are applied to this product in order to confirm the compliance.

Applicable standards (EMI)

EN55011, Class A

 

 

EN55022, Class B

Applicable standards (EMS)

EN61000-6-2

 

 

EN61000-6-1

* The length of the communication and power cables should be less than 30 m.

* To make the N-UP conform to the CE marking, attach the ferrite core to the USB cable as shown in the following diagram.

Recommended types

Model: ZCAT2035-0930 (TDK)

OP-31973 (Keyence)

Package Contents List

Main unit

Instruction manual

Dedicated Communication Unit

USB Output Type

N-UB

Instruction Manual

Foreign Regulations and Standards

For Safely Using the Product

Package Contents List

1

1

E N-UB-IM

KEYENCE N-UB User Manual

Part Names and Functions

 

 

 

 

 

 

 

 

 

1.

Head port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Power LED

 

 

 

 

 

 

 

 

 

 

 

3.

Communication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

status LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

USB port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. I/O status LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

I/O terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

Power terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. DIN rail mounting tab

 

 

 

 

 

 

 

 

 

Number

Name

 

Function

1

Head port

Used to connect the head.

 

 

 

 

 

2

Power LED

Lights when the power is ON.

 

 

 

 

 

3

Communication status

Monitors the status of communication with the

LED

head.

 

 

 

 

 

 

4

USB port

Used to connect to the personal computer.

 

 

 

 

 

5

I/O status LED

Monitors the ON/OFF status of I/O terminals.

 

 

 

 

 

6

I/O terminals

Used to connect I/O signal lines of control

units.

 

 

 

 

 

 

 

 

7

Power terminal

Terminal for 24V DC power supply input.

 

 

 

 

 

8

DIN rail mounting tab

A tab for mounting the DIN rail.

 

 

 

 

 

System Configuration Figure

Head

Head port

Personal

BL Series

 

computer

SR Series

 

 

 

 

 

PLC

 

 

USB port

Timing sensor

 

 

 

IN1

OUT1 to 4

Connection and Wiring Methods

Connecting the code reader

Connect the code reader to the head port of the N-UB.

Pin layout of the head port

 

 

 

 

Pin

Name

Signal name

Signal

 

2

1

 

number

direction

 

 

 

 

6

5

4

3

1

OUT1

OUT1 input

Input

 

 

 

 

10

9

8

7

2

OUT2

OUT2 input

Input

 

 

 

 

 

12

11

 

3

RXD

RS-232C Receive

Input

 

 

 

 

 

 

 

 

 

 

4

RTS

RS-232C Receivable

Output

 

 

 

 

 

 

 

 

Round 12-pin jack

5

OUT4

OUT4 input

Input

 

 

 

 

6

IN2

IN2 output

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

TXD

RS-232C Transmit

Output

 

 

 

 

 

 

 

 

 

 

 

 

8

CTS

RS-232C Transmittable

Input

 

 

 

 

 

 

 

 

 

 

 

 

9

OUT3

OUT3 input

Input

 

 

 

 

 

 

 

 

 

 

 

 

10

IN1

IN1 output

Output

 

 

 

 

 

 

 

 

 

 

 

 

11

+5V

+5V power supply

Output

 

 

 

 

 

 

 

 

 

 

 

 

12

GND(SG)

Common GND

-

 

 

 

 

 

 

 

 

Install and remove connection cables with the power CAUTION disconnected.

Connecting the power supply

Connect the 24 VDC power supply to the power terminal of the N-UB.

Twist pair cable

Power supply

24V+10% -20%

CAUTION

Using a power supply other than 24 VDC may cause

product failure.

 

 

 

The dimensions of crimp contacts used for wiring should be as follows:

Terminal

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

Round Terminal

a: 6 mm Max.

 

 

 

 

 

 

 

 

 

 

 

 

Y terminal

a: 6 mm Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

Description

 

 

 

 

 

Wire size

AWG14-22

 

 

 

 

 

 

 

 

 

 

 

 

Tightening torque

0.49 N·m (4.34 lbf·in)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire material

Copper

 

 

 

 

 

 

 

 

 

 

 

 

Wire type

Stranded wire

 

 

 

 

 

 

 

 

 

 

 

 

Electric wire

+60°C max.

 

 

 

 

 

temperature rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Layout and wiring of the I/O terminal block

Layout of the I/O terminal block

I/O terminal block

Symbol

Description

Signal

direction

 

 

INCOM

Common for IN terminal

-

 

 

 

IN1

Used as an input terminal for the code reader.

Input

 

IN2

 

 

 

 

 

OUTCOM

Common for OUT terminal

-

 

 

 

OUT1

 

 

 

 

 

OUT2

Used as an output terminal from the code reader.

Output

 

OUT3

 

 

 

 

 

OUT4

 

 

 

 

 

 

 

 

For connection, use stranded copper wire having a

Note

gage of AWG16 to 26 and temperature rating of 60°C

or higher.

 

 

 

The tightening torque is 0.19 N·m (1.7 lbf·in).

Wiring IN1 and IN2

Circuit diagram

IN1, IN2

Internal

circuit

INCOM

E N-UB-IM

2

 

 

 

Loading...
+ 2 hidden pages