INSTRUCTION |
Thank you very much for purchasing Panasinic products. |
|
|
||
|
|
Read this Instruction Manual carefully and thoroughly for |
|
|
|
MANUAL |
|
|
|
the correct and optimum use of this product. Kindly keep |
|
|
|
||
LED Display Digital Pressure Sensor |
this manual in a convenient place for quick reference. |
||
|
DP2 Series For use outside Japan
MJE-DP2 No.0048-50V
WARNING
●Never use this product as a sensing device for personnel protection.
●In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
●In case this sensor is used within Japan, SI unit must be used since use of pressure units in Japan is restricted to SI units.
1 SPECIFICATIONS |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
Vacuum pressure |
|
|
|
Positive pressure |
|
|
|||
|
|
Type |
|
-101kPa type |
|
|
100kPa type |
|
|
1MPa type |
|
||
|
|
|
Standard |
Flat |
IP67 |
Light weight |
Standard |
Flat |
IP67 |
Standard |
Flat |
IP67 |
|
|
<![if ! IE]> <![endif]>No. |
Asian |
DP2-20 |
|
DP2-60 |
DP2-80 |
DP2-21 |
DP2-41 |
DP2-61 |
DP2-22 |
DP2-42 |
DP2-62 |
|
|
North American (Note) |
DP2-20F(-P) |
DP2-40N |
DP2-60N |
DP2-21F(-P) |
DP2-41N |
DP2-61N |
DP2-22F(-P) |
DP2-42N |
DP2-62N |
|||
|
<![if ! IE]> <![endif]>Model |
||||||||||||
Item |
European |
|
DP2-40E |
DP2-60E |
|
|
DP2-41E |
DP2-61E |
|
DP2-42E |
DP2-62E |
||
|
|||||||||||||
Type of pressure |
|
|
|
|
Gauge pressure |
|
|
|
|
||||
Rated pressure range |
|
0 to -101.3kPa |
|
0 to 100.0kPa |
|
0 to 1.000MPa |
|||||||
Set pressure range |
|
5.1 to -101.3kPa |
|
-5.0 to 100.0kPa |
-0.050 to 1.000MPa |
||||||||
Pressure withstandability |
|
|
|
490kPa |
|
|
|
|
1.47MPa |
|
|||
Applicable fluid |
|
|
|
|
Non-corrosive gas |
|
|
|
|
||||
Selectable units |
kgf/cm2, bar, psi, mmHg, inHg |
|
|
kgf/cm2, bar, psi |
|
|
|||||||
Supply voltage |
|
|
|
12 to 24V DC +10-15 % Ripple P-P 10% or less |
|
|
|||||||
Current consumption |
|
|
|
|
50mA or less |
|
|
|
|
|
|
|
Asian |
|
|
|
|
<North American (Standard PNP output type), European> |
||||
Comparative outputs |
North American (Standard NPN output, Flat, IP67 types) |
PNP open-collector transistor |
||||||||||
NPN open-collector transistor |
|
|
|
|
Maximum source current: 100mA |
|||||||
Comparative Output 1 |
Maximum sink current: 100mA |
|
|
|
|
Applied voltage: 30V DC or less |
||||||
Comparative Output 2 |
Applied voltage: 30V DC or less (between comparative output and 0V) |
|
|
|
(between comparative output and +V) |
|||||||
|
|
|
Residual voltage: 1V or less (at 100mA sink current) |
|
Residual voltage: 2V or less (at 100mA source current) |
|||||||
|
|
|
0.4V or less (at 16mA sink current) |
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||||
|
Output modes |
Equipped with 4 types of modes: hysteresis mode, window comparator mode, dual output mode, automatic sensitivity |
||||||||||
|
setting mode (selectable by key operation) |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
||||
|
Hysteresis |
1 digit (However, variable in hysteresis mode and 2 digits when using psi unit) |
||||||||||
|
Repeatability |
|
|
Within ±0.2% F.S. ±1 digit |
|
|
|
|||||
|
Response time |
|
|
|
2.5ms or less |
|
|
|
||||
|
Short-circuit protection |
|
|
|
Incorporated |
|
|
|
||||
|
|
|
Output voltage: 1 to 5V (over rated pressure range) |
<![if ! IE]> <![endif]>(V) |
5 |
|
|
|
|
|||
|
|
|
|
|
|
|
||||||
|
|
|
Span: within 4V ±5% F.S. |
|
|
|
<![if ! IE]> <![endif]>voltage |
|
|
|
|
|
Analog voltage |
Zero-point: within 1V ±5% F.S. |
|
|
|
|
|
|
|
High pressure |
|||
output |
|
Linearity: within ±1% F.S. |
|
|
|
<![if ! IE]> <![endif]>Output |
1 |
|
|
|
(Positive pressure type) |
|
|
|
|
|
|
|
|
|
|
High vacuum |
|||
|
|
|
Output impedance: 1kΩ approx. |
|
|
|
|
|
||||
|
|
|
|
|
|
Pressure |
|
|
(Vacuum pressure type) |
|||
|
|
|
|
|
|
|
|
|
|
|||
Display |
|
31 digit red LED display (Sampling rate: 4 times/sec. approx.) |
||||||||||
|
|
|
2 |
|
|
|
|
|
|
|
|
|
|
Displayable pressure range |
5.1 to -101.3kPa |
|
|
-5.0 to 100.0kPa |
|
|
-0.050 to 1.000MPa |
||||
Analog bar display |
|
LED bar display in steps of 10% F.S. approx. |
|
|
|
|||||||
Operation |
Comparative Output 1 |
Orange LED (lights up when Comparative Output 1 is ON) |
||||||||||
indicators |
Comparative Output 2 |
Green LED (lights up when Comparative Output 2 is ON) |
||||||||||
Protection |
Standard Flat Light weight types: IP40 (IEC), IP67 type: IP67 (IEC) |
|||||||||||
Ambient temperature |
-10 to +50 (No dew condensation or icing allowed), Storage: -10 to +60 |
|||||||||||
Ambient humidity |
|
|
35 to 85% RH, Storage: 35 to 85% RH |
|
|
|
||||||
Pollution degree |
|
|
|
|
2 |
|
|
|
|
|
||
Overvoltage category |
|
|
|
|
II |
|
|
|
|
|
||
Usable altitude |
|
|
|
2,000m or less |
|
|
|
|||||
Temperature characteristics |
Over ambient temperature range -10 to +50 : within ±1% F.S. of detected pressure at 20 |
|||||||||||
|
|
Asian |
Standard Flat IP67 types: Rc (PT) 1 female thread, Light weight type: M5 female thread |
|||||||||
Pressure |
|
|
|
8 |
|
|
|
|
|
|
||
North American |
Standard type: NPTF 1 female thread, Flat IP67 types: NPT |
1 female thread |
||||||||||
port |
|
|
|
8 |
|
|
|
|
8 |
|
||
European |
|
Flat IP67 types: G (PF) 1 female thread |
|
|
|
|||||||
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
8 |
|
|
|
Front case: ABS, Rear case: PPS (glass fiber reinforced), Display surface: Acrylic
Material Pressure port attachment: Die-cast zinc alloy [Light weight type: POM (glass fiber reinforced), pressure port is brass (nickel plated)] Front cover (IP67 type only): Polycarbonate
Cable |
0.15mm2 5-core oil resistant cabtyre cable, 2m long (IP67 type: 5m long) |
Weight |
Standard type: 95g approx., Flat type: 120g approx., IP67 type: 370g approx., Light weight type: 70g approx. |
Accessories |
Hexagon-socket-head plug for pressure port: 1 No. (Standard type only), Pressure unit label: 1 No. |
Note: Model Nos. of North American standard type having the suffix '-P' are PNP output type.
2 CAUTIONS
DP2 series is designed for use with non-corrosive gas. It cannot be used for liquid or corrosive gas.
●This product has been developed / produced for industrial use only.
●Use within the rated pressure range.
●Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained.
●Make sure to carry out the wiring in the power supply off condition.
●Take care that wrong wiring will damage the sensor.
●Verify that the supply voltage variation is within the rating.
●If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
●In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground
●Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
●Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction.
●This product is suitable for indoor use only.
●Avoid use of standard type, flat type and light weight type of sensor in places where steam and dust is excessive.
●Take care that the sensor does not come in contact with water, oil, grease, or organic solvents, such as, thinner, etc.
●Do not insert wires, etc, into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained.
●Do not operate the keys with pointed or sharp objects.
●Make sure that stress by forcible bend or pulling is not applied directly to the sensor cable joint.
●Extension up to total 100m is possible with 0.3mm2, or more, cable. However, in case of using this product as a CE Marking conformity product, the power wire connected to this product must be within 10m.
3SETTING OF PRESSURE LEAD DIRECTION AND PIPING
Standard type
● Setting of pressure lead direction
The pressure lead direction can be changed by dismantling the pressure port attachment and changing the
mounting direction. The
tightening torque of the hexagon-socket-head
bolt (length 9mm or less) should be 0.29N m or less.
Main body
Hexagonsocket- head bolts
Pressure ports
Note: Please make sure to close any unused pressure port with the hexagon-socket-head plug supplied as accessory.
● Piping
When connecting a hexagon-socket-head plug or coupling to the pressure port, hold the hexagonal part of the pressure port with a 12mm spanner and make sure that the
tightening torque is 9.8N m or less. Also, in order to prevent any leakage, wind a sealing tape on the coupling when connecting.
However, sealing tape is not required for North American type using NPTF 1 8 coupling. (Sealing tape is required if NPT 1 8 coupling is used.)
Flat type, Light weight type
● Setting of pressure lead direction
The pressure lead direction can be changed by dismantling the pressure port attachment and changing the mounting direction. The tightening torque of the hexagon-socket-head bolt (length 9mm or less) should be 0.29N m or less.
Pressure port attachment
|
|
Hexagon-socket- |
|
|
head bolts |
Main body |
|
|
|
|
2-φ4.3mm mounting holes |
|
|
Pressure port |
● Piping |
|
|
When connecting a coupling |
|
|
to the pressure port, hold the |
|
|
pressure port |
attachment |
|
with a 16mm (Light weight |
|
|
type: 10mm) |
spanner and |
|
make sure that the tightening |
16mm |
|
torque is 9.8N m or less |
(light weight type: 10mm) |
|
(Light weight type: 1.47N m |
spanner |
or less). Also, in order to prevent any leakage, wind a sealing tape on the coupling when connecting.
IP67 type
● Piping for pressure measurement inlet port
When connecting a coupling to the pressure measurement inlet port, hold the pressure port attachment with a spanner and make sure that the tightening torque is 9.8N m or less. Also, in order to prevent any leakage, wind a sealing tape on the coupling when connecting.
● Piping for atmospheric pressure inlet port
If there is a possibility of water entering into the
sensor enclosure through the atmospheric pressure
inlet port, connect a tube to the atmospheric pressure inlet port through
a M5 coupling and extend the other end of the tube
to a safe place. In this case, ensure that this end
of the tube does not get clogged.
● Fitting of front cover
Insert the bosses on the front cover into the guide holes at the bottom of the pressure port attachment,
and push in the direction of the Hook arrow to fit the hook.
When removing the front cover, release the hook first.
Guide holes
4 MOUNTING OF STANDARD TYPE SENSOR
●A sensor mounting bracket MS-DPX and MS-DPX-4 (optional) may be used.
When mounting the sensor with the sensor mounting bracket, etc., the tightening torque should be 1.2N m or less.
<MS-DPX>
M4 (length 6mm) pan head screw (attached with MS-DPX)
Spring washer (attached with MS-DPX)
Sensor mounting bracket
MS-DPX (optional)
<MS-DPX-4>
Sensor mounting bracket
MS-DPX-4 (optional)
Spring washer |
M4 (length 6mm) pan head screw |
(attached with MS-DPX-4) |
(attached with MS-DPX-4) |
Note: In case mounting brackets or screws other than the sensor mounting bracket shown in the figure above are used, the length of the screws inserted into the pressure port attachment should be 5mm or less. If the length of the screws is longer than 5mm, the sensor may be damaged.
●Panel mounting bracket MS-DPX-2 (optional) and a front protection cover DPX-04 (optional) are also available.
Front protection cover |
|
|
DPX-04 (optional) |
DP2-20 |
- |
|
|
101.3kPa |
|
OUT1 |
|
|
0-ADJ |
OUT2 |
|
|
MODE |
Panel mounting bracket MS-DPX-2 (optional)
(Suitable for 1 to 3.2mm thick panel)
5 I/O CIRCUIT DIAGRAM
●NPN output type
|
|
|
Color code |
|
|
|
|
|
|
|
D |
(Brown) +V |
|
|
|
|
|
<![if ! IE]> <![endif]>circuit |
|
1kΩ |
(Gray) Analog |
|
|
|
|
|
|
(Black) Comparative Output 1 |
Load |
+ |
12 to 24V DC |
||||
|
ZD1 |
|||||||
|
|
|
voltage output |
Load |
|
|
|
|
|
|
|
(Note) |
|
|
|
|
|
<![if ! IE]> <![endif]>Sensor |
Tr1 |
|
|
100mA max. |
|
+10 |
||
|
|
|
- |
% |
||||
|
|
ZD2 |
100mA max. |
|
|
-15 |
||
|
|
(White) Comparative Output 2 |
|
|
|
|||
|
|
|
|
|
|
|||
|
Tr2 |
ZD3 |
(Blue) 0V |
|
|
|
|
|
|
|
|
|
|
|
|
|
Internal circuitUsers’ circuit
Note: The analog voltage output is not incorporated with a short-circuit protection circuit. Do not directly connect a power supply or a capacitive load. When using the analog voltage output, take care to connect external equipment of proper input impedance.
Also, when a cable extension is used, voltage drop due to cable resistance should be taken into account.
Symbols...D: Reverse supply polarity protection diode ZD1, ZD2, ZD3: Surge absorption zener diode Tr1, Tr2: NPN output transistor
●PNP output type
|
|
|
Color code |
|
|
|
|
|
|
D |
(Brown) +V |
|
|
|
|
<![if ! IE]> <![endif]>circuit |
Tr1 |
ZD1 |
(Black) Comparative Output 1 |
|
|
|
|
Tr2 |
|
+ |
|
||||
ZD2 |
100mA max. |
12 to 24V DC |
|||||
<![if ! IE]> <![endif]>Sensor |
|
|
(White) Comparative Output 2 |
|
|
||
|
|
100mA max. |
|
- |
+10 |
||
|
|
1kΩ |
Load |
% |
|||
|
|
(Gray)Analog |
Load |
|
-15 |
||
|
|
ZD3 |
voltage output (Note) |
|
|
|
|
|
|
(Blue) 0V |
|
|
|
|
|
|
|
|
|
|
|
|
Internal circuitUsers’ circuit
Note: The analog voltage output is not incorporated with a short-circuit protection circuit. Do not directly connect a power supply or a capacitive load. When using the analog voltage output, take care to connect external equipment of proper input impedance.
Also, when a cable extension is used, voltage drop due to cable resistance should be taken into account.
Symbols...D: Reverse supply polarity protection diode ZD1, ZD2, ZD3: Surge absorption zener diode Tr1, Tr2: PNP output transistor
6 FUNCTIONAL DESCRIPTION
|
DP2-20 |
-101.3kPa |
|
||
|
|
|
|
|
|
|
OUT1 |
OUT2 |
|
|
MODE |
|
0-ADJ |
|
|
|
|
|
|
|
Description |
|
Function |
|
31 2 digit LED |
Displays measured pressure, settings, |
|
display (Red) |
error messages and key-protect status. |
Comparative Output 1
operation indicator Lights up when Comparative Output 1 is ON. (Orange)
|
Comparative Output 2 |
Lights up when Comparative Output 2 is ON. |
||||
|
operation indicator |
|||||
|
(Green) |
|
|
|
||
|
|
|
|
In the initial setting mode, pressing |
<![if ! IE]> <![endif]>pressed |
|
|
|
|
|
the key changes the settable digit. |
|
|
|
|
|
|
In the Set Value 1, 2 modes, |
|
|
|
|
|
|
pressing the key changes the set |
<![if ! IE]> <![endif]>keysthebothare |
|
|
Increment key |
value to the high pressure side in |
<![if ! IE]> <![endif]>done.isadjustment |
|||
|
case of positive pressure type sensor |
|||||
|
( |
|
) |
and to the high vacuum side in case |
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
of vacuum pressure type sensor. |
|
|
|
|
|
|
In the sensing mode, if the key is |
|
|
|
|
|
|
pressed continuously for 4 sec. or more, |
|
|
|
|
|
|
the display shows peak hold value. |
|
|
|
|
|
|
In the initial setting mode, pressing |
<![if ! IE]> <![endif]>mode,if point-zero |
|
|
|
|
|
the key changes the set conditions. |
||
|
|
|
|
|
|
|
|
|
|
|
In the Set Value 1, 2 modes, |
|
|
|
|
|
|
pressing the key changes the set |
|
|
|
Decrement key |
value to the low pressure side in |
<![if ! IE]> <![endif]>sensingtheIn |
<![if ! IE]> <![endif]>simultaneously, |
||
|
case of positive pressure type sensor |
|||||
|
( |
|
) |
and to the low vacuum side in case |
||
|
|
|
|
|
|
|
|
|
|
|
of vacuum pressure type sensor. |
|
|
|
|
|
|
In the sensing mode, if the key is |
|
|
|
|
|
|
pressed continuously for 4 sec. or more, |
|
|
|
|
|
|
the display shows bottom hold value. |
|
|
|
|
|
|
Pressing the key changes the selected |
||
|
|
|
|
mode to sensing mode, Set Value 1 (P1) |
||
|
|
|
|
set mode and Set Value 2 (P2) set mode. |
||
|
|
|
|
In the sensing mode, if the key |
is |
Mode selection key pressed continuously for about 3 sec., ( MODE ) key-protect can be set/released.
In the sensing mode, if the mode selection key is pressed while pressing the increment key ( ), the initial setting mode is obtained.
7 ERROR MESSAGES
● When an error occurs, take the following corrective action.
Error message |
Cause |
|
Corrective action |
|||
|
|
|
|
Switch |
off |
the power |
|
Overcurrent |
|
due to supply |
and |
check the |
|
|
short-circuit. |
|
|
load. |
|
|
|
|
|
|
|
|
|
|
Pressure |
is |
being |
Applied pressure at the pressure |
||
|
applied |
|
during |
port should be brought to |
||
|
zero-point adjustment. |
atmospheric pressure and zero-point |
||||
|
adjustment should be done again. |
|||||
|
|
|
|
|
<![if ! IE]> <![endif]>Positive pressure type |
Applied pressure exceeds |
|||
|
displayable pressure range. |
||||
|
|
the |
upper |
limit |
of |
|
<![if ! IE]> <![endif]>Vacuum pressure type |
Applied pressure exceeds |
|||
|
displayable pressure range. |
||||
|
|
the |
lower |
limit |
of |
|
<![if ! IE]> <![endif]>Positive pressure type |
Applied pressure exceeds |
|||
|
displayable pressure range. |
||||
|
|
the |
lower |
limit |
of |
|
<![if ! IE]> <![endif]>Vacuum pressure type |
Applied pressure exceeds |
|||
|
displayable pressure range. |
||||
|
|
the |
upper |
limit |
of |
|
|
|
|
|
|
Applied pressure should be brought within the rated pressure range.
8 ANALOG BAR DISPLAY
●Pressure changes are displayed in an analog fashion by using LED bars. Hence, any sudden changes in pressure can be detected at a glance.
●The analog bar display shows the measured pressure, irrespective of the pressure unit, in steps of 10% F.S. approx. Please refer to ' 11 SETTING Initial setting' for the procedure to change to analog bar display.
Analog bar display for positive pressure type sensor
Atm. pressure condition |
|
High pressure condition |
DP2-21 |
100kPa |
DP2-21 |
100kPa |
DP2-21 |
100kPa |
OUT1 |
OUT2 |
OUT1 |
OUT2 |
OUT1 |
OUT2 |
|
MODE |
|
MODE |
|
MODE |
0-ADJ |
|
0-ADJ |
|
0-ADJ |
|
Analog bar display for vacuum pressure type sensor
Atm. pressure condition |
|
High vacuum condition |
DP2-20 |
-101.3kPa |
DP2-20 |
-101.3kPa |
DP2-20 |
-101.3kPa |
OUT1 |
OUT2 |
OUT1 |
OUT2 |
OUT1 |
OUT2 |
|
MODE |
|
MODE |
|
MODE |
0-ADJ |
|
0-ADJ |
|
0-ADJ |
|
9 OUTPUT MODES & THEIR CHARACTERISTICS
Hysteresis mode ()
●The common hysteresis of the comparative outputs can be set, as desired, with the set values.
|
|
Hysteresis |
|
Comparative ON |
|
Hysteresis: |
|
Output 1 |
OFF |
|
1 digit or more |
Comparative ON |
|
2 digits or more |
|
|
when using psi unit |
||
Output 2 |
OFF |
|
|
|
|
|
|
|
0 |
Set Value 1 (P1) |
Set Value 2 (P2) |
|
|
|
High pressure |
|
|
|
(Positive pressure type) |
|
|
|
High vacuum |
|
|
|
(Vacuum pressure type) |
Window comparator mode ()
●The comparative outputs can be turned ON or OFF by a pressure which is within the pressure range set by Set Value 1 and Set Value 2.
|
|
Hysteresis |
Hysteresis |
||||||||||
|
ON |
|
|
|
|
|
|
|
|
|
|
Hysteresis: 1 digit |
|
Comparative |
|
|
|
|
|
|
|
|
|
|
2 digits when using |
||
|
|
|
|
|
|
|
|
|
|
psi unit |
|||
Output 1 |
OFF |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
ON |
|
|
|
|
|
|
|
|
|
|
|
|
Comparative |
|
|
|
|
|
|
|
|
|
|
|
|
|
Output 2 |
OFF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
0 |
|
|
|
|
|
|
|
|
|
|
||
|
Set Value 1 (P1) |
Set Value 2 (P2) |
|||||||||||
|
|
|
|
|
|
|
|
|
High pressure |
||||
|
|
|
|
|
|
|
|
|
(Positive pressure type) |
||||
|
|
|
|
|
|
|
|
|
High vacuum |
||||
|
|
|
|
|
|
|
|
|
(Vacuum pressure type) |
When operating in window comparator mode ( ) Set Value 1 (P1) and Set Value 2 (P2) should be set with a difference of 3 digits or more. However, when the pressure unit is set to 'psi' (), the difference should be 6 digits or more.
Dual output mode ()
●The outputs can be put to different use such as detection of different kinds of objects, control function, alarm function etc.
|
|
Hysteresis |
|
|
|
||||
|
ON |
|
|
|
|
|
|
|
|
|
|
|
|
|
Hysteresis: 1 digit |
||||
Comparative |
|
|
|
|
|||||
Output 1 |
OFF |
|
|
|
|
2 digits when using |
|||
|
ON |
|
|
|
|
psi unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
Comparative |
|
|
|
|
|
|
|
|
|
Output 2 |
OFF |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
0 |
|
|
|
|
|
|
|
|
|
Set Value 1 (P1) |
Set Value 2 (P2) |
High pressure (Positive pressure type) High vacuum
(Vacuum pressure type)
Automatic sensitivity setting mode ()
●Using actual objects, if the pressure values for OK objects and NG objects are input, then the sensor is automatically set to the optimum pressure value (mid-value).
|
|
Hysteresis |
|
|
|||
|
ON |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Comparative |
|
|
|
|
Hysteresis: 1 digit |
||
Output 1 |
OFF |
|
|
|
|
||
|
|
|
|
2 digits when using |
|||
|
ON |
|
|
|
|
||
|
|
|
|
|
psi unit |
||
Comparative |
|
|
|
|
|
|
|
Output 2 |
OFF |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
||
|
0 |
|
|
|
|
|
|
|
Set Value 1 (P1) |
Set Value 2 (P2) |
|||||
|
|
Set Value 3 (P3) High pressure |
(Positive pressure type)
High vacuum
(Vacuum pressure type)
10 PRESSURE UNITS
●The pressure unit can be selected as per customer's requirement.
●In case of positive pressure type, the pressure unit can be changed from International System of Units (SI) 'kPa' or 'MPa' to 'kgf/cm2', 'bar' or 'psi'. In case of vacuum pressure type, the pressure unit can be changed from International System of Units (SI) 'kPa' to 'kgf/cm2', 'bar', 'psi', 'mmHg' or 'inHg'.
When the pressure unit is changed, the set values and the measured value are automatically converted.
Please refer to ' 11 SETTING Initial setting' for the procedure to change the pressure unit.
International System of Units (SI)
inHg |
kPa (Note) |
kgf/cm2 |
|
mmHg |
psi |
|
bar |
: Vacuum pressure type |
: Positive pressure type |
Note: 'MPa' in case of DP2-22□, DP2-42□ and DP2-62□.