KOHLER K-1652, K-1657, K-1658, K-1659, K-1695 Installation Manual

...
5 (2)

Installation Guide

Steam Generator

K-1652, K-1657, K-1658,

K-1659, K-1695, K-1708,

K-1733, K-1734

M product numbers are for Mexico (i.e. K-12345M)

Los números de productos seguidos de M corresponden a México (Ej. K-12345M)

Français, page“ Français-1” Español, página“ Español-1”

1060226-2-G

Tools and Materials

Plus:

Drain/spill pan

1/2" copper tubing

Assorted copper fittings; 3/8", 1/2" and 3/4" copper NPT unions

Wire Cutters or Wire Strippers

• Conventional woodworking tools and materials

• 45 and 90 degree elbows

• Support Blocks (heat resistant)

Hacksaw or Tube Cutter Drill w/ 1-1/4" &

Sealant Tape

Solder

 

2-1/2" Hole Bit

Propane Torch

 

 

 

 

Before You Begin

IMPORTANT! When using this unit, basic precautions should always be followed.

DANGER: Risk of electrocution. Disconnect the electricity to the working area at the main breaker panel before performing these installation steps.

WARNING: Risk of personal injury. If you become uncomfortable while taking a steam bath, you should power off the unit. Cool off with the shower, open the door, or exit the unit.

WARNING: Risk of allergic reaction. Before adding any oils, aromatic therapies, or skin care products to the aromatherapy well, make sure they will not cause an allergic reaction to the user.

WARNING: Risk of personal injury. This steam bath may not be suitable for use if you are pregnant, have a heart condition, have high blood pressure, have circulatory problems, are under the influence of alcohol, are taking drugs or are under the care of a physician. A steam bath can put undue stress on the body, as does any hot bath, shower, or sauna.

WARNING: Risk of personal injury. DO NOT consume alcoholic beverages or take medications/drugs prior to or when using the steam bath. Alcohol and drugs affect mental judgement and inhibit bodily functions such as heartbeat and respiration, resulting in potentially dangerous effects.

WARNING: Risk of injury to children. Do not allow children to use this unit unless they are closely supervised at all times. The steam generator is not designed to be used by children.

WARNING: Risk of personal injury. Do not plumb a trap in the steam line or plumb the pressure relief valve into the steam line. Plumbing the pressure relief valve into the steam line can be hazardous if the steam outlet is capped.

WARNING: Risk of personal injury or property damage. Avoid coming in contact with the water tank and/or steam discharge line while the generator is operating or shortly after shutdown. Wear eye protection and protective clothing when servicing the steam generator. The steam generator operates at high temperatures.

NOTICE: Use this unit only for its intended use as specified in this manual. DO NOT use attachments not recommended by Kohler Co.

NOTICE: Do not apply excessive heat to the generator connections when you solder connections. Do not apply flux or acids directly to the generator, as damage to the seals, plastic components, and trim finish may result. Do not apply petroleum-based lubricants to the generator components, as damage may result.

1060226-2-G

2

Kohler Co.

Before You Begin (cont.)

Inspect the product for any damage. Contact the KOHLER Customer Care Center using the information on the back of this guide.

Follow all local plumbing and electrical codes. All electrical work should be done by a qualified electrician.

Disconnect all power before making any electrical connections.

Kohler Co. reserves the right to make revisions in the design of products without notice, as specified in the Price Book.

Kohler Co.

3

1060226-2-G

Field Service Box

Install copper union in water feed line.

Tee

Shut-Off

Valve

 

Recommended In-Line

Water Filter

Control Cable

Input

Water Feed to Steam Generator

Pressure Relief Valve

Install copper union as close Water as possible to steam generator.

Inlet

Steam Head

Drain Pan

1. Determine the Layout

WARNING: Risk of property damage. Allow a minimum of 12(30.5 cm) of air space around the steam generator at all times. This provides an area for the heat generated by the unit to dissipate.

NOTICE: The steam generator will perform best when installed as close as possible to the steam head. The unit should be installed within 25’ (7.62 m) of the steam head.

NOTICE: For optimum performance install the steam generator below the level of the steam head.

NOTE: When possible, use 45 degree elbows. Performance will be increased when 45 degree elbows are used.

NOTE: The Recommended Layout Optionssections include information specific to Kohler bath and shower products. Refer to those sections for additional layout information.

Determine the location of the steam generator. Allow for a 12(30.5 cm) air gap on all sides of the generator. Allow for a drain pan.

Choose a drain pan appropriate for your installation. The drain pan is not supplied.

1060226-2-G

4

Kohler Co.

KOHLER K-1652, K-1657, K-1658, K-1659, K-1695 Installation Manual

12" (30.5 cm)

 

21"

 

21"

Control

 

Control

(53.3 cm)

 

(53.3 cm)

 

 

 

Control

Kit

 

Kit

 

 

Kit

4-1/2"

 

11"

 

 

11"

(11.4 cm)

 

(27.9 cm)

 

 

(27.9 cm)

60"

 

60"

 

 

60"

(152.4 cm)

 

(152.4 cm)

 

 

(152.4 cm)

Steam

6" (15.2 cm) Steam

6"

Steam

 

6"

Head

(15.2 cm)

Steam

(15.2 cm) Steam

K-1569/K-1669

Head

K-1687

Head

Head

Head

 

 

 

K-1688

21" (53.3 cm)

Control

 

 

Control

21" (53.3 cm)

 

Kit

 

 

Kit

 

Steam

4-1/2"

 

4-1/2"

Steam

(11.4 cm)

Steam

(11.4 cm)

Head

Head

 

 

6"

 

Head

 

 

60"

 

60"

6"

(15.2 cm)

 

 

(152.4 cm)

 

(152.4 cm)

(15.2 cm)

 

Drain End

 

Drain End

 

K-1683/K-1684

 

K-1681/K-1682

 

21" (53.3 cm)

Control

 

Control

21" (53.3 cm)

 

Kit

 

Kit

 

 

4-1/2"

 

4-1/2"

 

Steam

(11.4 cm)

 

(11.4 cm)

Steam

Head

60"

Steam

60"

Head

6"

Head

 

(152.4 cm)

 

(152.4 cm)

6"

(15.2 cm)

 

 

 

 

 

Drain End Drain End

 

(15.2 cm)

 

 

 

 

K-9486/K-9489

 

K-9488/K-9496

 

2. Determine the Location of the Steam Hardware

WARNING: Risk of personal injury. Do not install the Steam Control User Interface outside the steam enclosure. The User Interface must be installed within the enclosure to allow the sensors to regulate the temperature and control the flow of steam. Refer to the Installation Guide for the Steam Control Kit.

WARNING: Risk of scalding. Do not block the steam head or locate it near a seat or bench, as the steam head is hot during operation and may scald the user if touched.

Modules; Steam Head and Control Location

NOTE: All dimensions should be taken from the inside of the shower.

IMPORTANT! Do not install the control directly above or in-line with the steam head.

Review the layout options as an aid to determine the location for the components of the steam system.

Kohler Co.

5

1060226-2-G

Determine the Location of the Steam Hardware (cont.)

Identify the model number of the shower module as shown in the illustration.

Determine the location of the steam head and steam control for the module as shown in the modules illustration.

Ensure clearance between the steam line and any surrounding surfaces.

Refer to the Steam Control Kit Installation Instructions for more information.

For Custom Shower Applications

WARNING: Risk of personal injury. Do not install the Steam Control User Interface outside the steam enclosure. The User Interface must be installed within the enclosure to allow the sensors to regulate the temperature and control the flow of steam. Refer to the Installation Guide for the Steam Control Kit.

NOTE: All dimensions should be taken from the inside of the shower.

IMPORTANT! Do not install the steam control directly above or in-line with the steam head.

It is recommended to locate the steam head and the steam control on the same wall as the plumbing controls.

Locate the steam head 6(15.2 cm) above the shower floor and 4 1/2(11.4 cm) from the threshold.

Locate the steam control 60(152.4 cm) above the floor of the shower. Refer to the Steam Control Kit Installation Instructions for more dimensional and installation information.

Make sure there is adequate clearance between the steam line and any surrounding surfaces.

1060226-2-G

6

Kohler Co.

17-5/8" (44.8 cm)

3/8" NPT Water In

 

 

Minimum required access panel is

 

24" (61 cm) L x 15" (38.1 cm) H.

 

Allow for a minimum of 12" (30.5 cm) of

Field Wiring

space around all sides of the steam generator.

Allow for 3/4" (1.9 cm) space between the

Service Box

generator and the Drain/Spill Pan.

19-11/16" (50 cm)

3/4" NPT

 

Green LED

Pressure Relief

 

Diagnostic Light

 

 

Control

 

 

Cable Input

1/2" NPT

 

 

 

 

Steam Outlet

 

 

12-1/2"

 

10-1/4"

(31.8 cm)

 

(26 cm)

 

 

3/4"

 

3/8" NPT Drain

(1.9 cm)

 

Inside surface of Drain/Spill Pan

6-1/8" (15.6 cm)

3. Determine the Location of the Steam Generator

IMPORTANT! The minimum required access panel is 24(61 cm) L x 15(38.1 cm) H. Allow for a minimum 12(30.5 cm) space around all sides of the steam generator. Allow for 3/4(1.9 cm) space between the generator and the drain pan.

Ensure clearance between the steam line and any surrounding surfaces.

Allow for access to the steam generator after installation.

Allow for a 12(30.5 cm) air gap on all sides of the generator.

Allow for a drain or spill pan.

For optimum performance, install the steam generator below the level of the steam head and as close as possible to the steam head. The steam generator should be installed within 25 ft (7.62 m) of the steam head in a dry, well-ventilated area

4. Install the Electrical Supply

Model

K-1652 , K-1695

K-1657, K-1708

K-1658, K-1733

K-1659, K-1734

Ordering Information

 

 

 

Required Electrical Service

 

 

 

Generator -

5 kW, 240 V 40 A,

7 kW, 240 V, 50 A,

9 kW, 240 V, 60 A,

11 kW, 240 V, 60 A,

Dedicated

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

Circuit Required

 

 

 

 

Product Information

 

 

 

Weight

21 lbs (9.5 kg)

21 lbs (9.5 kg)

21 lbs (9.5 kg)

21 lbs (9.5 kg)

Electrical Rating

240 V, 27 A, 60 Hz

240 V, 36 A, 60 Hz

240 V, 45 A, 60 Hz

240 V, 46 A, 60 Hz

 

 

 

 

 

Kohler Co.

7

1060226-2-G

Install the

Electrical

Supply (cont.)

Water Supply

3/8copper line

3/8copper line

3/8copper line

3/8copper line

 

(3/8NPT female

(3/8NPT female

(3/8NPT female

(3/8NPT female

 

thread)

thread)

thread)

thread)

Steam Line

1/2copper line

1/2copper line

1/2copper line

1/2copper line

 

(1/2NPT thread)

(1/2NPT thread)

(1/2NPT thread)

(1/2NPT thread)

Pressure Relief

3/4NPT female

3/4NPT female

3/4NPT female

3/4NPT female

Valve (supplied)

thread

thread

thread

thread

Drain Line

3/8copper line,

3/8copper line,

3/8copper line,

3/8copper line,

Valve

(3/8NPT female

(3/8NPT female

(3/8NPT female

(3/8NPT female

 

thread)

thread)

thread)

thread)

Sizing The Steam Room

 

 

 

 

56 cu ft (1.6 cu m)

112 cu ft (3.2 cu m)

240 cu ft (6.8 cu m)

317 cu ft (9 cu m)

 

 

 

 

 

DANGER: Risk of electrocution. Disconnect the electricity to the working area at the main breaker panel before performing these installation steps.

Follow all local electrical codes. All electrical work should be done by a qualified electrician.

Review the illustration showing specific Steam Generator Installation Requirements for your Steam Generator.

Install the appropriate electrical supply.

1060226-2-G

8

Kohler Co.

Maintain a 12" (30.5 cm) space around the unit.

Control Cable

Pressure Relief Valve

Input

 

 

Inlet

 

Drain (install per

3/4" (1.9 cm) Min

applicable codes.)

Drain Pan

Steam Outlet

5. Install the Steam Generator

WARNING: Risk of property damage. Allow a minimum of 12(30.5 cm) of air space around the steam generator at all times. This provides an area for the heat generated by the unit to dissipate.

NOTICE: For optimum performance, install the steam generator as close as possible to the steam head. The steam generator must be installed within 25’ (7.62 m) of the steam head.

Install the desired drain pan at the steam generator location.

IMPORTANT! The support blocks should be constructed of heat resistant material.

Position support blocks so the steam generator will have 3/4(1.9 cm) of clearance from the drain pan.

Position the steam generator on the support blocks.

Kohler Co.

9

1060226-2-G

Pressure Relief Valve

 

 

Tee

 

 

 

Shut-Off

Copper

Copper

 

Valve

Union

Union

Pitch toward generator.

Water

 

 

Steam

Inlet

 

 

Recommended

 

 

Head

 

 

 

In-Line Water Filter

 

 

1" (2.5 cm) Min

 

 

 

Control Cable

 

 

 

Input

 

 

 

Steam Trap

 

 

Temporary

 

 

Nipple

 

 

 

 

 

 

Wall Stud

 

 

Provide clearance

 

 

from wall.

 

 

 

 

6" (15.2 cm)

 

 

 

from Floor

Do not run steam line down and then up.

2-1/2" (6.4 cm)

This will create a steam trap.

 

 

6. Install the Water Supply Line and Steam Line

WARNING: Risk of personal injury or property damage. Do not plumb the pressure relief valve into the steam line. Plumbing the pressure relief valve into the steam line can create a hazard if the steam line is blocked or obstructed.

WARNING: Risk of scalding. Do not plumb a trap, shut-off valve, or pressure relief valve into the steam line. Plumbing the pressure relief valve into the steam line can be hazardous, if the steam outlet is capped.

WARNING: Risk of personal injury or property damage. Do not direct the pressure relief valve to the enclosure. In the event the pressure relief valve activates, the hot water may spray causing burns to the user and/or damage the enclosure. Therefore, the pressure relief valve should be directed to an area where damage will not occur from contact with hot water and should conform to national and local plumbing codes.

Install the Water Supply Line to the Generator

NOTE: For all NPT threaded connections, use pipe tape or pipe sealant. Do not overtighten the fittings.

Connect to an existing cold water line, and run a 3/8cold water line to a shut-off valve before the in-line water filter.

Before final connection to the steam generator, flush out the water supply line into a large pail. This removes any debris, silt, sand, or other material that may be in the line.

Install 3/8copper tubing with a union fitting between the in-line water filter and the water inlet to the steam generator.

Connect the water supply line to the steam generator.

Make sure that the water drain valve on the generator is closed.

1060226-2-G

10

Kohler Co.

Install the Water Supply Line and Steam Line (cont.)

Fill the steam generator with water and check for leaks.

NOTICE: Steam generators are equipped with an automatic shut-off. The water will stop after the unit is full. If the water flows out of the steam outlet shut off the water and consult the Troubleshooting Guideor contact the Customer Care Center using the number located on the back of this document.

If the water supply line exceeds 10’ (3 m) or is exposed to cold areas, insulate the piping with appropriate insulation.

Install the Steam Line

WARNING: Risk of scalding. Do not locate the steam head near a seat or bench or scalding may occur upon contact with the steam head.

NOTICE: Never run the steam line down, then up. Running the steam line down and then up will create a steam trap, blocking the flow of steam. The steam line should run up to the steam head from the steam generator, at a pitch of 3/8(1 cm) to 1/2(1.3 cm) per 12(30.5 cm) of pipe.

NOTICE: Provide clearance between the back wall and the elbow leading into the steam housing. The elbow must not contact any wall material.

NOTICE: Provide clearance between the steam line and surrounding surfaces.

NOTICE: Do not apply excessive heat to the generator connections when you solder connections. Do not apply flux or acids directly to the steam generator, as damage to the seals, plastic components, and trim finish may result. Do not apply petroleum-based lubricants to the steam generator components, as damage may result.

NOTE: For all the threaded connections, use thread sealant tape or pipe sealant. Do not overtighten the fittings.

NOTE: Use 1/2copper tube for the steam line.

NOTE: Always install a union fitting as close to the steam generator as possible.

Add blocking behind the desired steam head location.

Install and secure a 1/2NPT elbow to the blocking directly behind the desired steam head location.

Cut a hole through the wall material to accept a temporary 1/2copper tube nipple. Add a temporary 1/2copper tube nipple.

Kohler Co.

11

1060226-2-G

240 VAC Source

 

 

 

 

 

Typical Two-Pole

 

N

L1

L2

Circuit Breaker

 

without GFCI

 

 

 

 

 

 

 

 

Breaker Box

 

 

 

 

*L2

 

 

120V

 

240V

Ground

 

 

*L1

Green

 

 

 

 

120V

Black - L2

 

240V

 

 

 

Ground

 

 

 

L1

Generator

 

 

L2

 

 

 

Black - L1

 

 

*Equipment Ground

Wire Connector (3)

 

 

 

 

Electrician to provide

 

Neutral Bus

 

suitable strain relief cable.

 

 

 

 

(In Breaker Box)

 

 

 

7. Connect the Power

DANGER: Risk of electrocution. Disconnect all power before performing these installation steps.

NOTICE: All electrical work should be done by a qualified electrician.

NOTICE: All electrical wiring must be done in accordance with local codes.

NOTICE: Each steam generator requires a dedicated circuit.

Connect the Power

Turn off all electricity to the working area at the main circuit breaker panel.

Connect 240 VAC electrical line to the wires labeled L1, L2, and the green (ground) wire coming out of the steam generator field service box located on top of the steam generator.

Confirm the ground connection has been made in the field service box.

Close the field service box.

Turn on the main power.

The function light should display a green light. If the function light is not green, consult the Troubleshooting Guideor contact the Customer Care Center using the number located on the back of this document.

8. Complete the Installation

Install the steam housing and steam head following the instructions packed with the Steam Control Kit.

Install the steam control following the instructions packed with the Steam Control Kit.

1060226-2-G

12

Kohler Co.

Complete the Installation (cont.)

To operate the steam control, follow the operation instructions provided with the Steam Control Kit.

Warranty

KOHLER Steam Generator

THREE-YEAR LIMITED WARRANTY

Kohler steam generator units manufactured after September 15, 2001, are warranted to the original consumer purchaser to be free of manufacturing defects in material and workmanship during normal residential usage for three (3) years from the date of installation. This warranty only applies to KOHLER steam generator units installed in the United States of America, Canada or Mexico (North America).

If a defect is found in normal residential usage, Kohler Co. will, at its election, repair or replace the unit, or make appropriate adjustment. Damage caused by accident, misuse or abuse is not covered by this warranty. Proof of purchase (original sales receipt) must be provided to Kohler Co. with all warranty claims. Kohler Co. is not responsible for labor charges, removal charges, installation, or other consequential costs. In no event shall the liability of Kohler Co. exceed the purchase price of the unit.

If this unit is used commercially or installed outside of North America, Kohler Co. warrants the unit to be free from defects in material and workmanship for one (1) year from the date of installation with all other terms of this warranty applying except duration.

To obtain warranty service contact Kohler Co., either through your Dealer, Plumbing Contractor, Home Center or E-tailer or by writing Kohler Co., Attn: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and 001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from within Canada, or www.mx.kohler.com in Mexico.

KOHLER CO. AND/OR SELLER ARE PROVIDING THESE WARRANTIES IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights, which vary from state/providence to state/providence.

This is Kohler Co.’s exclusive written warranty.

Troubleshooting Guide

CAUTION: Troubleshooting steps involving internal wires or electrical components should be performed by a qualified electrician.

NOTE: This troubleshooting only applies to the steam generator. For issues involving the steam control, consult the troubleshooting guide provided with the Steam Control Kit documentation.

The troubleshooting guide is for general aid only. For service and installation issues and concerns, contact the Customer Care Center using the information on the back of this guide.

Kohler Co.

13

1060226-2-G

Troubleshooting Guide (cont.)

Symptoms

Probable Causes

Recommended Action

1. The green LED light is

A. No electrical power at generator.

A1.

Reset the power at the breaker.

not on.

 

A2.

Have a qualified electrician verify

 

 

 

that 240 V of power is present at

 

 

 

the generator.

 

B. Circuit breaker is in the Off

B.

Turn on the power at the breaker.

 

position.

 

 

 

C. Circuit breaker is not the correct

C.

Verify the circuit breaker is sized

 

size.

 

appropriately. If it is the wrong

 

 

 

size, replace it.

 

D. Electrical connection in the field

D. Turn off all electrical power to the

 

service box on the generator is

 

generator. Have a qualified

 

loose.

 

electrician open the field service

 

 

 

box and check all connections.

 

 

 

Have a qualified electrician repair

 

 

 

any poor connections.

2. There is a continuous

A. Components internal to the

A1.

Shut off the water supply and

flow of water from the

generator are not functioning

 

drain the water from the generator.

steam head. Water flow

properly.

 

Close the drain valve.

during the power clean

 

A2.

Partially open the supply shut-off

cycle is normal.

 

 

valve a small amount.

 

 

A3.

Allow the water to gradually fill

 

 

 

the tank inside the generator (may

 

 

 

take several minutes). If the water

 

 

 

continues to flow from the steam

 

 

 

head, A1.

 

 

A4.

Fully open the water supply

 

 

 

shut-off valve.

 

 

A5. On models with power clean

 

 

 

option only, if water continues to

 

 

 

flow from the steam head, run the

 

 

 

power clean cycle.

 

 

A6.

If water continues to flow from the

 

 

 

steam head, contact the Customer

 

 

 

Care Center using the information

 

 

 

on the back of this guide.

 

B. The water supply is incorrectly

B.

Review the installation guide and if

 

connected to the generator.

 

necessary reconnect the water

 

 

 

supply to the proper location.

 

 

 

 

1060226-2-G