Model No. VL-SWD501 |
* Only for distribution in Europe, Middle East, Asia & Oceania |
|
|
|
|
|
|
|||||
|
|
|
Video Intercom System with Wireless Monitor (DECT) |
|
|
|
|
|
||||
System Configuration |
|
|
|
|
|
Wiring Schematic Diagram |
|
|
|
|
||
Expanded system example |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Up to |
|
Up to |
Up to |
|
|
DOOR STATION 1 |
|
|
|
|
|
|
5 |
|
4 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Supply Unit |
+ |
+ |
|
+ |
+ |
|
|
|
|
|
|
ELECTRIC LOCK |
Power |
|
|
|
|
|
|
|
|
Rear view |
|
(Electric vehicle gate lock)*1 |
|
|
|
DECT Wireless |
|
DECT Wireless |
DECT Wireless |
MAIN MONITOR |
|
|
||||
Video Intercom System |
Door Station |
|
Rear view |
|
|
|
|
|||||
Sub Monitor |
|
Sensor Camera |
Repeater |
|
|
|
|
|
||||
VL-SWD501 |
VL-V554 |
VL-WD613 |
|
VL-WD812 |
VL-FKD2 |
|
A |
NP |
Power |
12 V AC/DC |
|
|
|
|
|
|
|
|
|
|
|
|
Supply |
D |
|
|
|
|
|
|
|
|
|
NP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NP |
Power |
12 V AC/DC |
ELECTRIC LOCK |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
Supply |
|
(Electric door lock)*2 |
Bedroom |
Room 1 |
Room 2 |
DOOR STATION 2 |
NP
Power B
Supply Unit
|
|
|
|
|
24 V DC |
|
|
Rear view |
|
ELECTRIC LOCK |
|
|
|
Room 3 |
Room 4 |
Power |
|
|
|
|
|
*1 |
|||
|
Power |
|
|
|
|
|
|
(Electric vehicle gate lock) |
||||
Kitch |
Supply Unit |
|
NP |
|
|
|
|
|
||||
Den |
|
|
Supply Unit |
|
|
|
|
|
|
|
||
|
|
|
|
Garage |
|
|
|
NP |
|
12 V AC/DC |
|
|
|
|
|
|
|
|
E |
NP |
Power |
|
|
||
< 2 Wire > |
|
|
|
|
|
|
D |
|
|
|||
|
|
|
|
|
|
|
Supply |
|
|
|||
VL-PS241 |
|
Pool |
|
|
|
|
|
|
|
|
|
|
|
|
Power |
C |
220-240 V AC |
|
|
|
|
|
|
|
|
|
|
|
Supply Unit |
|
|
NP |
|
12 V AC/DC |
|
|
||
|
|
|
AC |
|
|
|
ELECTRIC LOCK |
|
||||
|
|
|
|
|
|
Power |
|
|||||
|
|
|
|
Connection device for option output |
|
|
|
|||||
Electric lock |
|
|
|
|
|
|
Supply |
|
(Electric door lock)*2 |
|
||
Electric lock |
|
|
POWER SUPPLY UNIT |
(A contact) |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
DECT Repeater * Up to 2 repeaters can be used.
The DECT Repeater can also be connected to increase usage area.
A single repeater can be used to send signals to either multiple sub monitors or cameras.
100m
Using one repeater
100m100m
Using two repeaters connected together
A single repeater cannot be used to send signals to both sub monitors and cameras.
100m |
100m |
100m |
* Signal range differs depending on factors such as the structure of rooms or the types of walls used.
NP: Non-polarised |
|
|
|
*1 Make sure to only connect electric vehicle gate locks to the S3/S4 terminals of the door stations. |
||||
|
|
|
|
(VL-SWD501EX, VL-SWD501FX models only) |
||||
|
|
|
|
*2 Make sure to only connect electric door locks to the S1/S2 terminals of the door stations. |
||||
Wire type and length |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wiring run |
|
|
|
|
|
Wire type*1 |
|
|
|
|
|
|
|
Diameter |
Length (Max.) |
|
|
Main monitor – Door station |
|
|
|
φ 0.65 mm |
|
22 AWG |
100 m |
|
|
A |
|
φ 1.0 mm |
|
18 AWG |
130 m |
|
|
|
|
|
|
φ 0.5 mm |
|
CAT 5 |
50 m |
|
Main monitor – Power supply unit |
|
|
|
φ 0.65 mm |
|
22 AWG |
10 m |
|
|
B |
|
|
|
||||
|
|
|
|
φ 1.0 mm |
|
18 AWG |
20 m |
|
Power supply unit – AC power source |
|
C |
|
φ 1.2 mm - φ 2.0 mm |
(17 AWG - 12 AWG) |
No requirement |
|
|
Door station – Electric lock*2 |
|
D |
|
φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG) |
According to specification of connected device. |
|
||
Main monitor |
|
|
|
φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG) |
According to specification of connected device. |
|
||
*2 |
E |
|
|
|||||
– Connection device for option output (A contact) |
|
|
|
|
|
|
|
|
Wireless sensor camera – Power supply unit |
|
- |
|
φ 0.65 mm |
|
22 AWG |
50 m |
|
|
|
|
|
φ 1.0 mm |
|
18 AWG |
100 m |
|
Power supply unit (for wireless sensor camera) |
|
|
- |
φ 1.2 mm - φ 2.0 mm (17 AWG - 12 AWG) |
No requirement |
|
||
– AC power source |
|
|
|
|||||
Wireless sensor camera – External sensor |
|
- |
|
φ 0.5 mm - φ 0.8 mm (24 AWG - 20 AWG) |
According to specification of connected device. |
|
||
|
|
|
|
|
|
|
Must be no longer than 20 m. |
|
*1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper solid
• A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option output (A contact), select a device that meets the following guidelines:
• Electric lock connection terminal (S1/S2, S3/S4): N/O dry closure contact 12 V AC/DC, less than 1 A
• Connection device for option output (A contact) terminal (OUT1/OUT2): 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)