Installation Guide |
||||
|
|
|
|
|
|
|
|
|
|
|
|
||
Model Name |
|
Model No. |
||||
Video Intercom System |
|
VL-SVN511 Series |
||||
Door station |
|
VL-V555 |
R This guide is for use with the above 2 models.
R The VL-SVN511 models composition consists of VL-MVN511 and VL-V555.
VL-MVN511 |
Main monitor station
VL-V555
Door station
R For VL-V555 users: Please refer to the installation guide of the main monitor that the doorphone is connected to.
R Door station is described as “doorphone” and Main monitor station is described as “main monitor” in this guide.
R In this guide, the suffix of each model number (e.g., the “EX” in “VL-SVN511EX”) is omitted unless necessary.
Note to the installer
R Before attempting to connect or operate this product, please read the label on the rear of the doorphone and the main monitor.
R Please read this guide carefully, and install the product safely and correctly by following the instructions. Carefully read the information found in the section titled “For your safety” in particular.
R Only use attachments/accessories specified by the manufacturer.
R The installation shall be carried out in accordance with all applicable installation rules. R Panasonic assumes no responsibility for injuries or property damage resulting from
failures arising out of improper installation or operation inconsistent with this guide. Additionally, any resulting malfunction will not be covered under the warranty.
R After installation, make sure to leave this guide with the customer.
For your safety
To prevent severe injury and loss of life/property, read this section carefully before using the product to ensure proper and safe operation of your product.
WARNING
Preventing fire, electric shock and short circuits
R Leave installation work to the dealer.
Installation work requires technique and experiences. Failure to observe this may cause fire, electric shock, injury, or damage to the product. Consult the dealer.
R Electrical connection work should be performed by certified personnel only. Certification is required for performing electrical connection work. Consult your dealer.
R Use only the specified power supply unit and AC cable.
R Do not attempt to disassemble or modify this product. Contact an authorised service centre for repairs.
R Never install wiring during a lightning storm. R Do not connect non-specified devices.
R Do not connect a power cable to a terminal that is not specified in this guide.
R When opening holes in walls for installation or wiring, or when securing the power cable, make sure you do not damage existing wiring and ductwork.
R Do not make any wiring connections when the power supply is turned on.
R Do not use the supplied power supply unit for outdoor installations (it is for indoor use only).
R Do not install the main monitor and power supply unit in the following places:
–Places where the main monitor and power supply unit may be splashed with water or chemicals.
–Places where there is a high concentration of dust, or high humidity.
R Do not perform any actions (such as fabricating, twisting, stretching, bundling, forcibly bending, damaging, altering, exposing to heat sources, or placing heavy objects on the power cable) that may damage the power cable. Using the product with a damaged power cable may
cause electric shock, short circuits, or fire. Contact an authorised service centre for repairs.
R When existing chime wires are used, it is possible that they contain AC voltage. Contact an authorised service centre.
Preventing accidents and injuries
R Do not install or use the product in health care facilities if any regulations posted in the area instruct you not to do so. Hospitals or health care facilities may be using equipment that could be sensitive to external RF (radio frequency) energy.
R Do not install or use this product near automatically controlled devices such as automatic doors and fire alarms. Radio waves emitted from this product may cause such devices to malfunction, resulting in an accident.
CAUTION
Preventing electric shock
R If the wiring is underground, do not make any connections underground.
R If the wiring is underground, use a protection tube.
R If the wiring is outdoors, use a protection tube or a surge protector.
Preventing injury
R Install the product securely adhering to the instructions in this guide to prevent it from falling off the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC (autoclaved lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls.
2
Supplied accessories for installation
For the doorphone
*1
Mounting base ´ 1 |
Screw ´ 4 |
Screw ´ 2 |
Name plate ´ 2 |
Hex wrench ´ 1 |
|
(4 mm ´ 12 mm) |
(3.8 mm ´ 20 mm) |
(incl. 1 spare) |
|
For the main monitor *2 |
Relay box *2 |
|
|
|
|
Cable binder ´ 2 |
|
Cable binder ´ 1 |
|
|
*1 |
|
*1 |
|
Mounting bracket ´ 1 |
Screw ´ 2 |
Relay box´ 1 |
Screw ´ 2 |
|
|
(4 mm ´ 16 mm) |
|
(4 mm ´ 40 mm) |
|
Power supply unit and related items *3 |
Power supply unit and related items *1 |
|
|
|
Cable binder ´ |
|
|
|
1 |
Power supply unit ´ 1 |
Cable binder ´ 2 Power supply unit ´ 1 |
AC cable ´ 1 |
Screw ´ 2 |
(Part No. VL-PS240) |
(Part No. VL-PS241) |
|
(4 mm ´ 40 mm) |
Important:
R You will need the following additional items to install and configure the doorphone and the main monitor.
[Locally procured] |
4 mm |
– Screws (for mounting base: ´ 2, for mounting bracket: ´ 2):*3 |
|
Prepare the screws (athe drawing on the right) according to the |
|
material, structure, strength and other factors of the mounting area |
|
and the total weight of objects to be mounted. |
|
–Power cables (AC/DC cables), wires (for doorphone and other connections): Prepare cables and wires of the appropriate specification. (a“Wire type and length”)
Note:
R The illustrations in the supplied manual(s) may vary slightly from the actual product.
*1 VL-SVN511 AZ models only
*2 VL-V555 models not included.
*3 VL-SVN511 EX/FX models only
3
Precautions for installation
To avoid malfunction or communication disturbances, do not install the doorphone or the main monitor in the following locations:
–Places where vibration or any other kind of impact occurs.
–Places where echoing is frequent.
–Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxious fumes.
For the doorphone
R If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable. Do not place the doorphone in the following locations:
–Where most of the background is the sky.
–Where the background is a white wall, and direct sunlight will reflect off it.
–Where direct sunlight will shine on the doorphone.
R Do not place the doorphone in locations where echoing occurs, as this will cause the doorphone to beep frequently.
R Dust protection/water protection is IP54.
Only when installation work specified in this guide is properly performed and appropriate water protection treatment is performed.
R Make sure the rear of the doorphone is not subject to water.
R Depending on the installation location, condensation may form on the doorphone’s lens cover. This may cause images to become obscured. Condensation will dissipate as the temperature rises.
For the main monitor
R Install the main monitor away from electronic appliances such as TVs, radios, personal computers, air conditioners, boiler control panels with intercom, home security equipment, wireless devices, or digital cordless phones.
R Do not install the main monitor in places where it will be affected by extremely high-frequency radio waves (near broadcasting antennas etc.). This may cause the display to flicker or an interrupting noise to occur.
R Leave at least 20 cm of space above, below, and to the left and right sides of the main monitor. Do not install on a wall that is deeply recessed.
R Do not install the main monitor inside a wall.
R Be sure to install the main monitor more than 5 m away from the doorphone.
R The product operates in the frequency range of 2.412 GHz and 2.472 GHz with a peak transmission power of 100 mW (max.). Refer to the “For best performance” section in the Operating Instructions.
R In areas surrounded by a high electrical field, disturbances may occur in the main monitor’s image or sound.
4
Wiring schematic diagram
Set up correctly according to the following wiring schematic diagram and “Wire type and length”.
R For information, such as order numbers, about optional devices that can be connected to, refer to the “Additional/replacement accessories” section in the Operating Instructions.
R For VL-V555 users: Refer to the wiring diagram of the Video Intercom device that VL-V555 is connected to.
DOORPHONE 1 *4 DOORPHONE 2 *4
*1 You can also connect an optional lobby station for apartment complexes. ("Connecting an optional lobby station" see page 7.)
|
MAIN MONITOR |
|
|
|
|
|
|
|
D1 |
1 |
|
A |
|
|
|
|
D2 |
2 |
|
|
|
|
|
|
D3 |
3 |
|
|
|
|
|
|
D4 |
4 |
|
|
|
|
|
|
R1 |
5 |
|
R2R3R1 |
2 |
S2S1 |
|
|
R3 |
7 |
|
|
|||
|
R2 |
6 |
|
|
1 |
|
NP |
|
|
|
|
|
1 |
|
|
|
IN1 |
8 |
|
D |
|
|
A |
|
IN2 |
9 |
|
|
S3 |
|
|
|
|
|
2 |
NP |
|||
|
IN3 |
10 |
|
|
|||
|
NP |
NP |
|
S4 |
|||
|
IN4 |
11 |
|
|
A |
||
|
|
|
|
|
|||
*1 |
P1 |
12 |
|
RELAY BOX |
|||
|
|
||||||
|
P2 |
13 |
|
F |
|
|
|
|
|
|
|
|
|
|
|
220-240 V AC *2 |
|
Connection device for option |
|
||||
|
Input (A contact) |
|
|
|
|||
|
|
B |
|
|
|
||
|
C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*3 |
|
|
G |
|
|
|
|
|
NP |
|
|
|
|
|
|
|
|
NP |
|
|
|
|
|
|
|
|
|
|
|
PBX |
|
|
|
|
Terminal box |
|
|
|
|
|
|
|
(4-conductor |
|
|
|
|
|
|
|
wiring) |
|
|
|
|
24 V DC |
|
|
|
|
|
|
POWER SUPPLY UNIT |
|
|
|
|
|
Electric lock
E
12 V AC/DC
12 V AC/DC
Electric lock
NP: Non-polarised
A Power supply
*1 VL-SVN511AZ models only
*2 VL-SVN511EX/FX models only
*3 VL-SVN511 AZ models: Use only the supplied AC cable.
*4 When you use an additional doorphone, the maximum number of the electric locks that can be connected to the doorphone depends on the type of doorphone. Consult your dealer for further information.
5
Wire type and length
Wiring run |
|
|
|
Wire type *1 |
|
|
|
|
Diameter |
Length (Max.) |
|||
|
|
|
||||
Main monitor – |
|
ø 0.65 mm |
|
22 AWG |
100 m |
|
Doorphone |
A |
ø 1.0 mm |
|
18 AWG |
130 m |
|
(including lobby station) |
|
ø 0.5 mm |
|
CAT 5 |
50 m |
|
|
|
|
||||
Main monitor – |
B |
ø 0.65 mm |
|
22 AWG |
10 m |
|
Power supply unit |
ø 1.0 mm |
|
18 AWG |
20 m |
||
|
|
|||||
Power supply unit – |
C |
ø 1.2 mm – ø 2.0 mm |
No requirement |
|||
AC power source |
(17 AWG – 12 AWG) |
|||||
|
|
|||||
Main monitor – |
D |
ø 0.65 mm |
|
22 AWG |
100 m |
|
Relay box |
ø 1.0 mm |
|
18 AWG |
130 m |
||
|
|
|||||
Relay box – |
|
ø 0.5 mm – ø 1.2 mm |
According to |
|||
E |
specification of |
|||||
Electric lock *2 |
(24 AWG – 17 AWG) |
|||||
|
connected device. |
|||||
|
|
|
|
|
||
|
|
|
|
|
|
|
Main monitor – |
|
ø 0.5 mm – ø 1.2 mm |
According to |
|||
Connection device for |
F |
specification of |
||||
(24 AWG – 17 AWG) |
||||||
option input (A contact) *2 |
|
connected device. |
||||
|
|
|
|
|||
Main monitor – |
G |
ø 0.65 mm |
|
CAT 3 or 22 AWG |
100 m |
|
PBX |
|
|||||
|
|
|
|
|
*1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper solid
R A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option input (A contact), select a device that meets the following guidelines:
R Electric lock connection terminal (S1/S2, S3/S4):
–N/O dry closure contact
–12 V AC/DC, less than 1 A
R Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):
–Input method: No-voltage contact
–Open-circuit voltage between terminals: DC 7 V or less
–Detection definite time: 0.1 second or more
–Short-circuit between terminals: 5 mA or less
–Resistance value: make: 500 W or less make, break: 15 KW or more
6