Silvercrest KH 8105 User Manual

4 (1)

IAN 61572

KOMPERNASS GMBH

BURGSTRASSE 21

D-44867 BOCHUM

www.kompernass.com

Last Information Update Tietojen tila Informationsstatus

Tilstand af information: 10 / 2010 3 Ident.-No.: KH8105 - 10/2010 - V2

PERSONAL CARE

Forehead & Ear Thermometer

KH 8105

Forehead & Ear Thermometer

Operation and Safety Notes

Otsaja korvakuumemittari

Käyttöja turvallisuusohjeet

Pannoch örontermometer

Bruksanvisning och säkerhetsanvisningar

Pandeog øretermometer

Betjeningsog sikkerhetshenvisninger

Before reading, unfold both pages containing illustrations and familiarise yourself with all functions of the device.

Käännä ennen lukemista molemmat kuvalliset sivut esiin ja tutustu seuraavaksi laitteen kaikkiin toimintoihin.

Vik ut båda bildsidorna och ha den till hands när du läser igenom anvisningarna och gör dig bekant med apparatens / maskinens funktioner.

Før du læser, vend begge sidene med billeder frem og bliv bekendt med alle apparatets funktioner.

 

GB /IE

Operation and Safety Notes

Page

5

 

 

FI

Käyttöja turvallisuusohjeet

Sivu

35

 

 

SE

Bruksanvisning och säkerhetsanvisningar

Sidan

63

 

 

DK

Betjeningsog sikkerhetshenvisninger

Side

89

 

 

 

 

 

 

 

Silvercrest KH 8105 User Manual

A 1 2 3 4 9

5

6

8 7

 

10

11

B

25

12

 

24

13

 

23

14

 

22

15

 

21

16

 

20

17

 

19

 

 

18

 

C

SET 12hr

SET 24hr

 

 

(12/24)

(12/24)

SET hour

SET minute

 

 

 

SET sleep

SET Year

SET month

SET day

disable

D E

F G

 

Table of Contents

Introduction

 

 

Intended use .................................................................

Page

7

Scope of delivery .........................................................

Page

8

Description of parts ......................................................

Page

8

Technical data...............................................................

Page

9

Safety

 

 

General safety instructions...........................................

Page

11

Safety instructions .........................................................

Page

13

Safety Instructions for the Battery ................................

Page

14

Before getting started

 

 

Removing the battery fuse............................................

Page

15

Operation

 

 

Setting the date / time...................................................

Page

15

Temperature measurements .........................................

Page

16

Measuring time (stopwatch mode)..............................

Page

23

Functions / error analysis

 

 

Selecting the temperature unit .....................................

Page

24

The memory function (memory mode)

...........................Page

24

Changing the battery ....................................................

Page

25

Problem-solving.............................................................

Page

26

Cleaning and care.............................................

Page

28

Guarantee and Service................................

Page

29

Disposal......................................................................

Page

31

Conformity ..............................................................

Page

32

 

GB/IE

5

The following pictograms are used in these directions for use or on the device itself:

Read the directions for use!

Please observe the warning and safety instructions!

Risk of explosion!

V

Direct current (type of current and voltage)

 

mA Milliampere

Danger to life and danger of accidents for infants and children!

Medical device type B

Year and month of manufacture

Dispose of the packaging and appliance in an environmentally friendly way!

6 GB/IE

Introduction

Forehead & Ear Thermometer

Introduction

Before starting the device up for the first time, familiarise yourself with its functions. Read the following directions for use. Please keep these instructions in a safe place. When handing the device on

to a third party, hand all instructions on, too.

Intended use

The device is intended for use indoors for the measurement of body temperature on the ear or temple / forehead, the measurement of room temperature and the measurement of surface temperatures in the household, as well as a clock with stopwatch function. In no way does it replace an examination by a qualified doctor. This appliance is solely intended for private use. Any use other than that previously described or any change to the product is not permitted and may lead to injuries and / or damage to the product. The manufacturer does not assume any liability for damage arising from improper use.

GB/IE 7

Introduction

Scope of delivery

1 x Forehead and ear thermometer

(incl. battery and protective head guard 9 ) 1 x Directions for use

Description of parts

1 “MEM / SET” button

(information retrieval from the memory etc.)

2 Measuring head

3“EAR” button

(temperature measurement in the ear scan mode)

4“FOREHEAD” button

(temperature measurement on the forehead / temple)

5 LC display

6 LED red fever 38.0 °C - 42.9 °C (100.4 °F - 109.2 °F)

7LED orange slight increase in temperature 37.5 °C - 37.9 °C (99.5 °F - 100.2 °F)

8LED green no fever 34.0 °C - 37.4 °C (93.2 °F - 99.3 °F)

9Protective head guard

(can also be attached to the foot for better grip)

10Battery compartment lid

11Battery

8 GB/IE

Introduction

LC display

12Battery change symbol

13Year display symbol

14Date display symbol

15Ear mode symbol

16Standard mode symbol

17Scan mode symbol

18Temperature display

19Forehead mode symbol

20Sleep mode symbol

21Setup mode symbol

22Memory mode symbol

23PM / AM display

24Month and hour in standard mode

25Stopwatch mode symbol

Technical data

Measurement

 

 

 

method:

Infrared (non-contact)

Electrical

 

 

 

power supply:

Lithium battery 3 V

 

CR2032

 

Power consumption:

< 30 mA

Memory:

9 temperature measurements with

 

details of date, time and measurement

 

method (ear or forehead measurement)

GB/IE 9

Introduction

Temperature scale:

°C (°Celsius)

 

°F (°Fahrenheit)

Time display:

12 / 24-hour format

Automatic switch-o : Automatic switch-o after 1 minute Measurement range

forehead & ear mode: 32°C - 42.9°C (89.6°F - 109.2°F) Measurement

accuracies:

± 0.2°C (± 0.4°F) in the range

 

from 35.5°C - 42.0°C

 

(95.9°F - 107.6°F)

 

± 0.3°C (± 0.5°F) in the range from

 

32.0°C - 35.4°C (89.6°F - 95.7°F)

 

and in the range from 42.1°C -

 

42.9°C (107.8°F - 109.2°F)

Measurement range

 

room temperature:

5.0°C - 59°C (41.0°F - 138.2°F)

Measurement

 

accuracy:

± 2.0°C (± 4.0°F)

Measurement

 

range scan mode:

–22.0°C - 80.0°C

 

(–7.6°F - 176°F)

Measurement

 

accuracy:

± 2.0°C (± 4.0°F)

Ambient temperature

Ear and scan mode:

+10.0 °C - +40.0 °C

 

(50.0 °F - 104.0 °F)

Forehead mode:

+15.0 °C - +40.0 °C

 

(59.0 °F - 104.0 °F)

10 GB/IE

 

Introduction / Safety

Storage temperature:

–10.0 °C - +55.0 °C

 

(14.0°F - 131.0°F) at

 

20 % RH* - 85 % RH*

Atmospheric pressure:

700 ~ 1060 hPa

Dimensions:

135 x 37 x 58 mm (L x B x H)

Weight:

50 g

*RH = relative humidity

Safety

PLEASE KEEP ALL SAFETY INFORMATION

AND INSTRUCTIONS FOR FUTURE USE!

 

General safety instructions

 

WARNING! DANGER TO LIFE

 

AND DANGER OF ACCIDENTS FOR

 

INFANTS AND CHILDREN! Never leave

 

children alone and unsupervised with the packaging

 

material. Danger of su ocation. Children often

 

underestimate risks. Always keep children away

 

from the product.

DANGER TO LIFE! Batteries can be swallowed, which may represent a danger to life. If a battery has been swallowed, medical help is required immediately.

GB/IE 11

Safety

This device is not designed to be used by people (including children) with limited physical, sensory or mental abilities or who lack the experience and / or knowledge to use it, unless they are supervised by a person responsible for safety or receive instructions from such a person as to how the device should be used. Children have to be supervised to ensure that they do not play with the device.

Do not expose the device to

-extreme temperatures,

-strong vibrations,

-heavy mechanical loads,

-direct sunlight.

Otherwise there is a danger that the device will be damaged.

Please note that the guarantee does not cover damage caused by incorrect handling, non-compliance with the operating instructions or interference with the device by unauthorised individuals.

Under no circumstances should you take the device apart. Improper repairs may place the user in considerable danger. Repairs should only be carried out by specialist personnel.

Do not use the device if it is damaged. Otherwise the consequence may be injuries and / or inaccurate readings.

12 GB/IE

Safety

Please consult a doctor if the thermometer indicates that the body temperature measured is high. With this

measuring method, a fever is indicated if the temperature is above 38.0 °C (100.4 °F). The red LED 6 is a

warning. Please take several measurements at intervals of 0.5 to 1 hour in order to follow the progression of the temperature. The values you measure will help your doctor make a diagnosis.

Do not use the temperature under extreme temperature conditions and / or outdoors. This will result in inaccurate measuring results. Please observe the details regarding ambient and storage temperatures (see “Technical data”).

The infrared sensor should not be touched directly or blown on. This will result in inaccurate measuring results.

Mobile telephones should not be used in the immediate vicinity when the thermometer is being used. Otherwise the consequence may be inaccurate measurement results.

Safety instructions

This appliance is solely intended for private use. That is why it is not subject to mandatory verification.

Do not continue to use the device if it is damaged or if the measured values appear unrealistic to you. Consult the section entitled “Functions / error analysis - problemsolving” or contact our service centre.

GB/IE 13

Safety

Safety Instructions for the Battery

Remove the battery from the device if it is not going to be used for a prolonged period.

 

 

CAUTION! DANGER OF EXPLOSION!

 

 

 

The battery must never be recharged!

 

 

 

Ensure correct polarity when inserting the battery! This is indicated in the battery compartment.

If necessary, clean the battery and device contacts before inserting the battery.

Batteries must not be disposed of in the normal domestic waste!

Every consumer is legally obliged to dispose of batteries in the proper manner!

 

 

 

CAUTION! RISK OF EXPLOSION!

 

 

 

 

 

Keep batteries away from children; do not

 

 

 

throw batteries into a fire; do not short-circuit

 

 

 

 

the batteries and do not take them apart.

Avoid contact with the skin, eyes and mucous membranes. Any parts of the body coming into contact with battery acid should be rinsed o with copious amounts of water and / or a doctor contacted if necessary!

Avoid contact with skin, eyes and mucous membranes. Upon contact with battery acid, rinse the a ected area with lots of water and / or consult a doctor!

14 GB/IE

Before getting started / Operation

Before getting started

Removing the battery fuse

Push the battery compartment lid 10 downwards.

Pull the tab of the protective film out of the battery compartment.

Push the battery compartment lid 10 onto the battery

compartment until it clicks into place (Fig. A).

When it is switched on, an internal alignment and a self-test of the LC display are carried out.

In order to check if all bars of the numbers are activated correctly, please check the image of the display of your appliance with the sample (Fig. B) when you switch the appliance on.

Operation

Setting the date / time (Fig. C)

You only have to set the date and time when you operate the appliance for the first time and after you change the battery.

1. Press and hold the “MEM / SET” button 1 down for two seconds in standard mode. An acoustic signal will sound. The device is now in set-up mode.

2. Press the “MEM / SET” button 1 to choose between the 12-hour or 24-hour format.

GB/IE 15

Operation

3.Press the “FOREHEAD” button 4 . The hours will flash and can be corrected with the “MEM / SET” button 1 .

4.Press the “FOREHEAD” button 4 again. The minutes will flash and can be corrected with the “MEM / SET” button 1 .

Repeat steps 3 and 4 to set the values for the year, month and day or to switch the sleep mode on or o .

Temperature measurements

Measuring room temperature (standard mode)

When you have finished setting the time and date and do not carry out any further procedures, the device switches to sleep mode after 1 minute in order to save the battery. In the condition as supplied to the customer the sleep mode is activated, as shown by the symbol, and the LC display 5 is completely switched o . When the sleep mode is deactivated, the device remains switched on, while the time and room temperature are still shown and updated once a minute. The LC display 5 shows

the time and date alternately (Illustration D).

Measuring body temperature (ear mode)

IMPORTANT! It is advisable to carry out 3 measurements in a row on the same ear and to take the highest temperature as the measured value. A new measurement can be taken when the display “” goes out.

16 GB/IE

Operation

Do not use the thermometer if pain occurs when the measurement is being taken. This could damage the ear canal.

Do not use the thermometer with external ear disorders (e.g. inflammation of the ear canal, injuries to the outer ear). The condition of the a ected areas could worsen.

Do not use the thermometer straight after bathing or swimming when the ear canal is wet. This could damage the ear canal.

Due to the risk of contamination of the measuring head, clean the appliance after every use.

In this mode, only measure the temperature in the ear and at no other place on the body.

1.If the sleep mode has been activated, activate the thermometer again by pressing any button before taking the measurement.

2. Carefully press on the protective cap 9 and remove it with a gentle rotary motion and without using any force.

3.Check that the measuring head 2 and the measuring sensors are clean.

4.Carefully clean the ear canal with a cotton bud.

5.Please pull the outer ear slightly in the direction of the back of the head and diagonally upwards or backwards so that the ear canal is freely accessible and there are no obstacles between the infrared reception and the ear drum.

GB/IE 17

Operation

6.Please keep the outer ear slightly extended and now carefully insert the measuring head 2 into the ear canal.

7. Briefly press the “EAR” button 3 . The symbol will appear in the LC display 5 and the measurement

will start after an acoustic signal.

8.The end of the measurement is indicated by means of 2 acoustic signals.

9.Now you can read o the measurement result on the

LC display 5 . At the same time, one of the 3 LEDs will come on.

Note: LED green 8 no fever 34.0 °C - 37.4 °C (93.2 °F - 99.3 °F)

LED orange 7 slight increase in temperature 37.5 °C - 37.9 °C (99.5 °F - 100.2 °F)

LED red fever 6 38.0 °C - 42.9 °C

(100.4 °F - 109.2 °F)

10.Values can be displayed in °C as well as in °F (see “Functions / error analysis - selecting the temperature unit”).

11.Wait until the display “” goes out before you start taking a new measurement.

Note: The appliance automatically switches o if it is not operated for longer than 1 minute. When the sleep mode has been activated, the LC display 5 switches itself o .

When the sleep mode has been deactivated, the appliance switches to standard mode. If the thermometer has been operated under normal conditions, the result of the last measurement taken before the appliance was switched o

18 GB/IE

Operation

is stored. The measured value is available again along with information on the date, time and measurement mode when the “MEM / SET” button 1 is pressed again. The

device has 9 storage spaces (see section on “Functions / error analysis - the memory function”).

Measuring the body temperature (forehead mode)

IMPORTANT! It is advisable to carry out 3 measurements in a row at the same place and to take the highest temperature as the measured value.

With di erent room temperatures, let the appliance lie in the room where the temperature is to be taken for at least 30 minutes to “acclimatise” it.

Before measuring your body temperature, you should relax for about 5 minutes.

If you have done any physical activity or taken a bath, wait for at least 30 minutes before taking a measurement in order to get a measurement that is as accurate as possible.

Ensure that the forehead or temple is clean, free of injuries and not covered with sweat, cosmetics or ointment.

Take a note of what measurement method you used to measure the temperature and inform your doctor of it.

1.If the sleep mode has been activated, activate the thermometer again by pressing any button before taking the measurement.

GB/IE 19

Operation

2. Carefully press on the protective cap 9 and remove it with a gentle rotary motion and without using any force.

3.Check that the measuring head 2 and the measuring sensors are clean.

4.Hold the measuring sensor 1 cm away from the forehead or temple.

5.To start the measurement, press on the “FOREHEAD” button 4 . The symbol will appear in the LC display 5 and the measurement will start after an acoustic signal.

6.The end of the measurement is indicated by 2 acoustic signals.

7.Now you can read o the measurement result on the

LC display 5 . At the same time, one of the 3 LEDs will come on.

Note: LED green 8 no fever 34.0 °C - 37.4 °C (93.2 °F - 99.3 °F)

LED orange 7 slight increase in temperature 37.5 °C - 37.9 °C (99.5 °F - 100.2 °F)

LED red fever 6 38.0 °C - 42.9 °C

(100.4 °F - 109.2 °F)

8.Values can be displayed in °C as well as in °F (see “Functions / error analysis - selecting the temperature unit”).

9.Repeat steps 3 to 6 to carry out further measurements.

20 GB/IE

Operation

Note: The appliance automatically switches o if it is not operated for longer than 1 minute. When the sleep mode has been activated, the LC display 5 switches itself o .

When the sleep mode has been deactivated, the appliance switches to standard mode. If the thermometer has been operated under normal conditions, the result of the last measurement taken before the appliance was switched o is stored. The measured value is available again along with information on the date, time and measurement mode when the “MEM / SET” button 1 is pressed again. The

appliance has 9 storage spaces (see “Functions / error analysis - the memory function”).

Use as a household thermometer (scan mode)

The thermometer can also be used in the house for non-contact temperature measurements in the range of –22.0 °C - 80.0 °C (–7.6 °F - 176.0 °F).

Attention! Do not use this mode for measuring body temperature.

With this measurement, the current surface temperature of the object is displayed. It can be di erent from its internal temperature, especially if the surface is exposed to direct sunlight or a draught!

Due to its design, the thermometer measures the precise value when its casing has adjusted to room temperature. That is why you should not hold it in the hand for a long time when you want to take a measurement and why you should keep it away from direct sunlight!

GB/IE 21

Operation

Do not use the appliance immediately after cleaning the measuring head 2 . The evaporative cooling e ect of the detergent may falsify the measuring result.

Sample applications:

-The temperature of milk in baby bottles

-The temperature of bathwater

1.If the sleep mode has been activated, activate the thermometer again by pressing any button before taking a measurement.

2. Carefully press on the protective cap 9 and remove it with a gentle rotary motion and without using any force.

3.Make sure that the measuring head 2 and the measuring sensor are clean.

4.Press the “FOREHEAD” button 4 and the “EAR”

button 3 repeatedly at the same time until “Food” is shown in the LC display 5 (Illustration E).

5.Hold the measuring head at a distance of 1 cm from the liquid and / or surface whose temperature you want to measure.

6.Press the “EAR” button 3 to start the measurement.

7.Now you can read o the measurement result on the LC display 5 (Illustration E).

8.Values can be displayed in °C as well as in °F (see “Functions / error analysis - selecting the temperature unit”).

22 GB/IE

Operation

9.Press the “EAR” button 3 again to carry out further measurements.

10.The appliance automatically switches o if it is not operated for longer than 1 minute. This application is not stored in the device.

In order to return to standard mode, proceed as follows:

1.Press the “FOREHEAD” button 4 and the “EAR” button 3 repeatedly at the same time until the LC

display 5 again shows the room temperature, date and time, as well as the symbol (Illustration D).

2.You are now back in standard mode.

Measuring time (stopwatch mode)

The integrated watch can be used as a stopwatch in the range of 0.01 seconds to 3 minutes. This function is required to calculate the pulse rate. The appliance has to be switched over to stopwatch mode to do so.

1.If the sleep mode has been activated, activate the thermometer again by pressing any button before taking a measurement.

2.Press the “FOREHEAD” button 4 and the “EAR” button 3 repeatedly at the same time until the LC

display

5

shows the

symbol (Illustration F).

3.The stopwatch is started by pressing the “FOREHEAD” button 4 and stopped by pressing it again.

GB/IE 23

Operation / Functions / error analysis

4. You can start a new measurement by pressing the “MEM / SET” button 1 to delete the previously measured time.

In order to return to standard mode, proceed as follows:

1.Press the “FOREHEAD” button 4 and the “EAR” button 3 repeatedly at the same time until the LC

display 5 again shows the room temperature, date and time, as well as the symbol (Illustration D).

2.You are now in standard mode again.

Functions / error analysis

Selecting the temperature unit

Press and hold down the “EAR” button 3 and the “FOREHEAD” button 4 at the same time until “°F” appears behind the temperature display. Switching from “°F” to “°C” is possible with the same procedure.

The memory function (memory mode)

IMPORTANT!

The current measurement is always stored in the last storage space. When all storage spaces have been occupied, the oldest measurement is always deleted from the memory.

24 GB/IE

Functions / error analysis

Measurements taken in ear and forehead mode are automatically stored in the appliance. The measured values are available again along with information on the date, time and measurement mode when the “MEM / SET” button 1 is operated in standard mode. Press the “MEM / SET” button 1 once to retrieve the value of the last measurement. The “Memory” symbol (memory mode), the number of the measurement, date, time and measurement mode will appear in the LC display 5 (Fig. G). By pressing the “MEM / SET” button 1 the next storage space along

with its associated measured value will appear. A maximum of 9 measurements can be stored.

In order to return to standard mode, proceed as follows:

1.Press the “FOREHEAD” button 4 and the “EAR” button 3 repeatedly at the same time until the LC

display 5 again shows the room temperature, date and time, as well as the symbol (Illustration D).

2.You are now in standard mode again.

Changing the battery

The appliance is fitted with a lithium battery (CR2032, 3 V ) that allows a lot of measurements to be taken. If the battery is empty, you will be made aware of that by

means of an appropriate error message (see “Functions / error analysis - problem-solving”).

GB/IE 25

Functions / error analysis

Push the battery compartment lid 10 downwards. Lever the battery 11 out with a small screwdriver.

Avoid short-circuiting the battery at all cost. A shortcircuit can occur if the screwdriver comes into contact with the battery and the live parts in the battery compartment at the same time.

Insert the new battery into the battery compartment. Note: Ensure correct polarity. The plus sign on the battery must point upwards.

Push the new battery under the metal nose and press it down until it clicks into place.

Push the battery compartment lid 10 onto the battery compartment until it clicks into place (Fig. A).

Problem-solving

If the appliance cannot take a measurement in the designated range, it will generate an error message. This message should help to solve the problem.

 

 

Error

Problem

Solution

 

 

 

 

 

 

 

Appliance does

Empty battery?

Insert a new

 

 

not react /

 

battery

 

 

automatically

 

 

 

 

Wrong battery

Removing battery

 

 

resets itself

 

 

polarity?

and insert it

 

 

when protective

 

 

 

correctly

 

 

Faulty battery

 

 

film is removed

 

 

 

 

 

 

 

 

contact?

 

 

 

 

 

 

 

 

 

26

 

GB/IE

 

 

 

 

 

 

 

 

 

 

 

 

 

Functions / error analysis

Error

 

 

Problem

Solution

 

 

 

 

 

 

Battery symbol

Weak battery

Insert a new

on the LC

 

 

 

battery

display

5

 

 

 

 

 

 

 

 

 

 

“Lo” on the

Is the thermometer

Follow the direc-

LC display

5

 

correctly positioned

tions for use with

(measured

 

 

at the eardrum or

regard to position-

value below

forehead / temple?

ing it at the ear-

32.0°C or

 

 

 

drum or forehead /

89.6°F)

 

 

 

temple.

 

 

 

 

 

 

“Hi” on the

 

 

Check the

Please observe

LC display

5

 

operating mode.

the directions for

(measured

 

 

 

use with regard to

value above

 

taking correct

42.9°C or

 

 

 

measurements.

109.2°F)

 

 

 

 

 

 

 

 

 

 

“ErrE” on the

Ambient tempera-

Please ensure an

LC display

5

 

ture outside the

ambient tempera-

 

 

 

 

range of 15.0 °C -

ture in the range

 

 

 

 

40.0 °C / 59.0 °F -

of 15.0 °C -

 

 

 

 

104.0 °F (fore-

40.0 °C / 59.0 °F -

 

 

 

 

head mode) and

104.0 °F (fore-

 

 

 

 

10.0 °C - 40.0 °C /

head mode) and

 

 

 

 

50.0 °F - 104.0 °F

10.0 °C - 40.0 °C /

 

 

 

 

(ear and scan

50.0 °F - 104.0 °F

 

 

 

 

mode).

(ear and scan

 

 

 

 

 

mode)

 

 

 

 

 

 

GB/IE 27

Functions / error analysis / Cleaning and care

Error

Problem

Solution

 

 

 

 

 

 

 

“ErrU” on the

No measurement

Please observe

LC display

5

 

result after

the directions for

 

 

 

 

 

measurement.

use with regard to

 

 

 

 

 

 

taking correct

 

 

 

 

 

 

measurements.

 

 

 

 

 

 

 

“ErrH” on the

Error detected

Contact the

LC display

5

 

during self-test.

service centre.

 

 

 

 

 

 

 

“ErrP” in LC

Hardware

Contact the

display

5

 

problem

service centre.

 

 

 

 

 

 

 

Cleaning and care

The lens in the opening of the measuring sensor is the most sensitive part of the appliance.

Be very careful when you have to clean it. In order to avoid contamination with germs, the lens has to be rubbed after every use with a soft cloth that has been moistened with 70% medical alcohol. The use of hygiene attachments is, therefore, not necessary. After that, wait for at least

30 minutes before taking another measurement. Please keep in mind that due to the evaporative cooling e ect of the alcohol, even the smallest amounts can falsify the result. Clean the housing with a soft, slightly damp cloth. In the case of more severe soiling a mild detergent can also be added to the water.

28 GB/IE

Cleaning and care / Guarantee and Service

Keep the appliance in a dry environment and protect from direct sunlight. The appliance can be stored at temperatures of –10.0 °C - 55.0 °C (14.0 °F - 131.0 °F). Temperatures over 80.0 °C are to be avoided! In order to measure with it, however, it is necessary to let the appliance adjust to room temperature for a su cient length of time - otherwise an error message will be generated (see “Functions / Fault Analysis - Correction of Problems”). A room temperature of 5.0°C - 59.0°C (41.0°F - 138.2°F) should also be maintained for the purposes of measurement. If the temperature is outside this range, an error message is shown (see “Functions / Fault Analysis - Correction of Problems”). Remove the battery when not using the appliance for any length of time.

Guarantee and Service

This appliance is guaranteed for 3 years from the date of purchase. It has been carefully produced and meti-culously checked before delivery. Please keep your receipt as proof of purchase. Contact your service centre by telephone in case of questions pertaining to the warranty. Your goods can be transmitted free of cost only in this manner.

GB/IE 29

Guarantee and Service

The warranty covers only material or manufacturing faults, not normal wear or damage to fragile parts such as switches or rechargeable batteries. The appliance is intended solely for private, not commercial, use.

If this product has been subjected to improper or inappropriate handling, abuse, or interventions not carried out by one of our authorised sales and service outlets, the warranty will be considered void. This warranty does

not a ect your statutory rights.

The guarantee period is not extended by the warranty. This also applies to replaced and repaired parts. Any damage or defects present when the device is purchased must be reported immediately upon unpacking, and not later than two days after the date of purchase. All repairs required after the guarantee period has expired are subject to a charge.

GB

DES UK LTD

Tel.: 0871 5000 700 (£ 0.10 / minute) E-Mail: support.uk@kompernass.com

30 GB/IE

Guarantee and Service / Disposal

IE

Kompernaß Service Ireland

Tel.: 1850 930 412 (0,082 € / Min.)

*Standard call rates apply. Mobile operators may vary.

E-Mail: support.ie@kompernass.com

Disposal

The packaging is made entirely of recyclable materials, which you may dispose of at local recycling facilities.

Contact your local refuse disposal authority for more details of how to dispose of your worn-out product.

The product is subject to Directive 2002 / 96 / EC (WEEE). In the interests of environmental protection, do not throw the product away with domestic waste when it is worn out, but take it to a proper disposal facility. Contact your local authority to find out about collection centres and their opening times.

GB/IE 31

Disposal / Conformity

Faulty or used batteries must be recycled in accordance with Council Directive 2006 / 66 / EC. Take used batteries and / or the appliance itself to the collection facilities provided.

Batteries should not be disposed of with domestic waste!

Take batteries and / or the product itself to the collection facilities provided.

Conformity

The CE Mark 0123 has been attached to this product in accordance with the following European Directive:

Directive for Medical Products 93/42/EEC, as amended by Directive 2007/47/EC.

The associated declaration of conformity has been deposited with the importer:

KOMPERNASS GMBH BURGSTRASSE 21

44867 BOCHUM, GERMANY www.kompernass.com

32 GB/IE