Hilti PD-30 Manual

0 (0)

PD 30

en

*372204*

000000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 2

9

10

9

7

10

4

8

6

3 1

Hilti PD-30 Manual

 

 

PDA 50

PDA 80

PDA 60

PDA 81

PDA 61

PDAW 80-1

PDA 62

PDAW 80 / 81-1

PDA 70

PDAW 80 / 81-2

PA 970

PDAW 80 / 81-3

 

PDAW 81-1

PD 30 laser range meter

Contents

It is essential that the operating instructions are read before the range meter is used the first time.

Always keep these operating instructions together with the tool.

Ensure that the operating instructions are with the range meter when it is given to other persons.

Component parts

Laser exit apertureControl panel

Receiving lensPlastic casing

Horizontal bubbleBattery compartmentFolding spike

Graphic display of operating status Metal contact points for precise measurement (3x rear)

Metal supports for precise measurement (3x underneath)

Optical sight

Contents

1. General information . . . . . . . . . 3

1.1.Safety notices and their meaning 3

1.2. Pictograms . . . . . . . . . . . . . . . . 3

1.3.Location of identification data on

the range meter . . . . . . . . . . . . . 3

2. Description . . . . . . . . . . . . . . . . 4 2.1. Intended use . . . . . . . . . . . . . . . 4 2.2. Items supplied. . . . . . . . . . . . . . 4 2.3. Measuring principle . . . . . . . . . . 4 2.4. Range meter functions. . . . . . . . 4 2.4.1. General range meter functions . . 4

3. Tools and accessories. . . . . . . . 5 3.1. PDA 50 target plate . . . . . . . . . . 5 3.2. PDA 80 / 81charging kit. . . . . . . 5 3.3. PDAW 80-1 mains adaptor. . . . . 6

3.4.PDAW 80 / 81-2 car battery plug 6

3.5.PDAW 80 / 81-1 charging adaptor6

3.6. PDAW 80 / 81-3 battery pack . . . 6 3.7. PDAW 81-1 mains adaptor. . . . . 6 3.8. PA 970 laser visibility glasses . . 6

4. Technical data . . . . . . . . . . . . . 7

5. Safety information . . . . . . . . . . 8 5.1. Basic safety information. . . . . . . 8 5.2. Misuse . . . . . . . . . . . . . . . . . . . 8

5.3.Proper organization of workplace 9

5.4. Electromagnetic compatibility. . . 9 5.4.1. Laser classification . . . . . . . . . . 9 5.4.2. General safety precautions . . . . . 9 5.4.3. Transport. . . . . . . . . . . . . . . . . . 9

1

Contents

6. Getting started . . . . . . . . . . . . 10

6.1.Inserting alkaline / rechargeable

batteries . . . . . . . . . . . . . . . . . 10 6.2. Battery charging . . . . . . . . . . . 10

6.2.1.Standard charging of batteries . 10

6.2.2. Fast battery charging . . . . . . . . 10

6.3.Switching the range meter On

and Off . . . . . . . . . . . . . . . . . . 10

6.3.1.Initial distances measurement . 11

6.4. Settings . . . . . . . . . . . . . . . . . 12 6.4.1. Activating the setting menu . . . 12 6.4.2. Menu / Beep . . . . . . . . . . . . . . 12 6.4.3. Menu / Units . . . . . . . . . . . . . . 12 6.4.4. Exiting the menu . . . . . . . . . . . 12

7. Operation . . . . . . . . . . . . . . . . 12 7.1. General controls . . . . . . . . . . . 12 7.1.1. Control panel . . . . . . . . . . . . . 12 7.1.2. On and shift keys . . . . . . . . . . . 12 7.1.3. Measure keys . . . . . . . . . . . . . 13 7.1.4. Function keys . . . . . . . . . . . . . 13 7.2. Display . . . . . . . . . . . . . . . . . . 13 7.2.1. Symbols displayed. . . . . . . . . . 14 7.2.2. Display illumination . . . . . . . . . 15 7.3. Measuring distances . . . . . . . . 15 7.3.1. Measuring references . . . . . . . 15

7.3.2.Measuring distances step by step 15

7.3.3. Measurement mode . . . . . . . . . 16

7.3.4.Measuring from corners . . . . . 17

7.3.5.Measuring with the aid of

target objects. . . . . . . . . . . . . . 17

7.3.6.Measuring in bright surroundings17

7.3.7.Taking measurements to

rough surfaces . . . . . . . . . . . . 18

7.3.8.Taking measurements to

round or inclined surfaces . . . . 18

7.3.9.Taking measurements to

wet or shiny surfaces. . . . . . . . 18 7.3.10. Taking measurements to

transparent surfaces . . . . . . . . 18 7.3.11. Measuring ranges . . . . . . . . . . 18

8. Applications . . . . . . . . . . . . . . 19 8.1. Measured data memory . . . . . . 19 8.1.1. Saving measurements . . . . . . . 19 8.1.2. Historical data memory . . . . . . 19 8.2. Area measurement. . . . . . . . . . 19 8.3. Volume measurement . . . . . . . 20 8.4. Adding of distances . . . . . . . . . 21

8.5.Subtracting of distances . . . . . 21

8.6. Setting out . . . . . . . . . . . . . . . 22

9. Calibration and adjustment. . . 23 9.1. Calibration . . . . . . . . . . . . . . . . 23 9.2. Adjustment . . . . . . . . . . . . . . . 23 9.3. Hilti calibration service. . . . . . . 23

10. Care and maintenance . . . . . . 24 10.1. Cleaning and drying . . . . . . . . . 24 10.2. Storage . . . . . . . . . . . . . . . . . . 24 10.3. Transportation . . . . . . . . . . . . . 24

11. Disposal . . . . . . . . . . . . . . . . . 24

12. Warranty . . . . . . . . . . . . . . . . . 25

13.FCC statement (applicable

in USA) . . . . . . . . . . . . . . . . . . 25

14. EC declaration of conformity. . 26

2

1. General information

1. General information

1.1 Safety notices and their meaning

- CAUTION -

This word indicates a possibly hazardous situation which could result in slight bodily injuries or damage to property.

- NOTE -

This word indicates information to help the user employ the product efficiently, and other useful notes.

1.2 Pictograms

Warning signs

General warning

Laser class 2

(Do not stare into the beam.)

1.3 Location of identification data on the range meter

The type designation and serial number can be found on the rating plate on the range meter. Make a note of this data in your operating instructions and always refer to it when making an enquiry to your Hilti representative or service department.

Type :

Serial-No.: ___________

®

AVOID EXPOSURE

Laser radiation is emitted

Hilti = registered trademark of Hilti Corporation,

Schaan, Liechtenstein

from this aperture

Type: PD 30

 

 

 

30.

LASER RADIATION - DO NOT

2

7/A 845

STARE INTO BEAM

620-690nm/0.95mW max.

 

91

CLASS II LASER PRODUCT

 

3

 

 

Made in

1/4 s

Germany

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference,

and (2) this device must accept any interference received, including interference that may cause undesired operation.

Symbols

Read the operating instructions before use.

These numbers refer to the corresponding illustrations. The illustrations can be found on the fold-out cover pages. Keep these pages open when studying the operating instructions. In these operating

instructions, the PD 30 laser range meter is referred to as "the range meter".

3

2. Description

2. Description

The distance is determined along an emitted laser beam up to the surface where the laser beam is reflected. The red laser spot clearly identifies the target from which the measurement is taken.

The measuring range depends on the reflectivity and the surface structure of the target surface.

2.1 Intended use

The range meter is designed for the:

Measurement of distances

Calculation of areas, volumes and distances

Addition and subtraction of distances

Operation and storage in the specified temperatures

2.2 Items supplied

1PD 30 laser range meter

1PDA 60 hand strap

2Type AA batteries

1 soft pouch

1 Operating instructions

2.3 Measuring principle

The range meter emits a visible laser beam with measuring waves, which are reflected returning with a phase shift. The phase shift is used to determine the distance.

This measuring principle permits highly accurate and reliable distance measurements to objects without special reflectors.

2.4 Range meter functions

2.4.1 General range meter functions

Reference point shift On / off

Liquid display

 

 

 

Measure key

 

 

 

 

Volume function

 

 

 

Addition of distances

Area function

 

 

 

Subtraction of distances

Horizontal bubble level

 

 

 

Battery charging contacts

 

 

 

 

 

Spike

 

Display

illumination

 

 

 

 

phi

4

3. Tools and accessories

3. Tools and accessories

Description

Designation

Target plate

PDA 50

Hand strap

PDA 60

Soft pouch

PDA 61

Belt clip

PDA 62

Measuring extension

PDA 70

Charging kit

PDA 80

Charging kit

PDA 81

Mains adaptor

PDAW 80-1

Mains adaptor

PDAW 81-1

Car battery plug

PDAW 80/81-2

Charging adaptor

PDAW 80/81-1

Battery pack

PDAW 80/81-3

Laser visibility glasses*

PA 970

* These are not laser safety glasses and do not protect the eyes from laser radiation. The laser visibility glasses restrict colour vision. Therefore these are not permitted to be worn by a person driving on a public road, and must not be used look straight into the sun.

3.1 PDA 50 target plate

The PDA 50 target plate is made of durable plastic with a special reflective coating. In poor light conditions, it is advisable to use the target plate for distances above 10 m (30 ft).

- NOTE -

For reliable distance measurements the laser beam should be perpendicular to the target plate whenever possible. If this not the case, the laser spot on the target plate may not be in the same plane as the target point and the distance measured will be incorrect.

For very accurate measurements using the target plate, 1.2 mm (1/20 inch) should be added to the measured distances.

3.2 PDA 80 / 81 charging kits

The PDA 80 and PDA 81 charging kits enables the use of the range meters with rechargeable cells. The battery charging time takes approx.12 hours for empty cells. However, sufficient current is charged within the first 15 minutes – for 150 - 200 measurements.

Please also refer to the description of battery charging in section 6. Getting started.

Contents of PDA 80 charging kit

Mains adaptor 100 – 240 V AC with 2-pole Europlug

Car battery plug

Charging adaptor for range meter

2 chargeable battery cells (NiMH)

Contents of PDA 81 charging kit

Mains adaptor 100 – 240 V AC

with 4 interchangeable plugs for US, GB, AUS, EU.

Car battery plug

5

3. Tools and accessories

Charging adaptor for range meter

2 chargeable battery cells(NiMH)

3.3 PDAW 80-1 mains adaptor

The mains adaptor is an integral part of the charging kit. It is equipped with a two pin plug. The mains adaptor transforms the power supply from alternating current to direct current which is used to charge the batteries. The mains adaptor automatically adjusts itself to suit an AC voltage between 100 - 240 V and 50 - 60 Hz. The mains adaptor has been specially designed to supply current to the charging adaptor.

- NOTE -

Battery chargers or mains adaptors with other voltage outputs, such as those for mobile phones, may not be used. Use of other battery chargers or mains adaptors may damage the range meter.

3.4 PDAW 80/81-2 car battery plug

The car battery plug is an integral part of the PDA 80/81 charging kit. It can be inserted into a vehicle cigarette lighter or into sockets of the same design. This adaptor has a special design and transforms the 12 - 24 V direct current of a vehicle battery into a voltage suitable for the charging adaptor.

A light-emitting diode (LED) is incorporated in the adaptor to indicate correct connection for charging. An additional fuse in the adapters front section provides protection against voltage peaks.

- NOTE -

As the car battery plug has been especially designed to charge the NiMH batteries of

the PD30, it may not be replaced by other types of car battery plugs.

3.5PDAW 80/81-1 charging adaptor

The respective mains adaptor supplies current to the charging adaptor. Prior to charging the battery, the side flange connections should be carefully checked.

3.6PDAW 80/81-3 battery pack

The battery pack consists of two rechargeable, 1.2-V NiMH cells with a capacity of approx.1800 mAh. The battery pack remains in the battery compartment while being charged.

- NOTE -

A "memory effect" is virtually non-exi- stent with this type of batteries and the charging process used. The charging process can be interrupted at any time without damaging the battery cells.

Other brands of rechargeable batteries can be used. It must be ensured, however, that, as far as possible, batteries have a similar capacity of approx.

1800 mAh.

3.7 PDAW 81-1 mains adaptor

This mains adaptor PDAW 81-1 is virtually identical to the PDAW 80-1 mains adaptor. The only difference is the type of mains plugs which are interchangeable plugs.

3.8 PA 970 laser visibility glasses

The laser visibility glasses clearly improve the visibility of the laser beam (spot)

6

Loading...
+ 21 hidden pages