Hilti P 20 Manual

4 (1)

PD 20

Operating instructions

*334057*

334057

Operating instructions

PD 20 laser range meter

In addition to the instructions for use, this manual also contains important safety information (see “Safety precautions” section).

Please read these instructions carefully before using the product.

Symbols

The symbols used in these operating instructions have the following meanings:

Warning

Operating risk or misuse which may lead to serious personal injury or death.

Caution

Operating risk or misuse which may lead to only minor personal injuries, but to serious material, property or environmental damage.

Information to help the operator use the product in a technically correct and efficient manner.

Product identification

The type designation and serial number can be found on a name plate attached to the rear of the product. Make a note of this information in the operating instructions and always refer to it when addressing any enquiries to our agents or service department.

Type: PD 20

Serial no.:

 

Contents

1.

Product information .............................

5

 

Description of functions ..................................

5

 

Display and control panel ...............................

7

 

Symbols displayed ...............................

7

 

Button functions ....................................

8

 

Instructions at a glance ..................................

9

 

Technical data ...............................................

11

 

Items supplied ..............................................

13

2.

Safety information ..............................

14

 

Please read this now! ...................................

14

 

Purpose ........................................................

14

 

Intended uses .....................................

14

 

Examples of misuse ...........................

14

 

Operating limits ............................................

15

 

Division of responsibilities ............................

15

 

Operating risks .............................................

16

 

Disposal .......................................................

20

 

Laser classification .......................................

21

 

Information plate ..........................................

22

 

Electromagnetic compatibility (EMC) ...........

24

3.

Operation .............................................

25

 

Inserting the batteries ...........................

25

 

Menu selection and setting ...................

26

 

Menu overview ...................................

26

 

rEF menu / reference point .................

26

 

CONST menu / constants ..................

27

 

Light menu / display illumination ........

27

 

dELAY menu / self-timer .....................

27

 

bEEP menu / beep sound ..................

28

 

Unit menu / measurement units .........

28

4. Working with the PD 20 ......................

29

 

Measuring distances ....................................

29

 

Measuring using the spike ..................

30

 

Continuous measurement (tracking) ..

31

 

Measuring using the self-timer ...........

32

 

Measuring with the aid of a target object 33

2

3

continued

 

Contents

4. Working with the PD 20, continued

 

 

Taking measurements from various

 

 

surfaces ..............................................

34

 

Using the calculation functions ....................

35

 

Adding / subtracting (distances) .........

35

 

Multiplication (areas / volumes) ..........

36

 

Calculating with Pythagoras ...............

38

 

Calculating using a constant value .....

40

5.

Care, transportation and storage ......

41

 

Cleaning and drying .....................................

41

 

Storage ........................................................

41

 

Transportation ..............................................

41

6.

Symbols displayed .............................

42

7.

Measuring equipment inspection .....

43

8.

Accessories ........................................

44

 

Batteries .......................................................

44

 

Target plates ................................................

44

 

Laser sighting glasses .................................

44

9.

FCC statement (applicable in US) .....

45

10. EC declaration of conformity ............

46

11. Warranty ..............................................

47

1. Product information

1. Product information

Description of functions

The Hilti PD 20 is a laser range meter. It makes use of a laser beam to measures distances within the 0.3 m - 100m range with great precision and without physical contact.

3

2

1

6

5

4

7

8

9

1 Laser exit aperture

2 Display

3 Control panel

4 Receiving lens

5 Plastic casing

6 Bubble level

7 Battery compartment

8 Spike (folding)

9 Two tripod mounting threads

4

5

continued

1. Product information

Description of functions, continued

The point from which the measurement is taken is clearly identified by the red spot. The range of the tool depends on the reflectance and surface finish at the point where the measurement is taken. The reference point on the tool can be selected for different types of measurements.

Distances between 0.3 and 30 m

-Target the object directly.

-Use the white target plate.

Distances between 30 and 100 m

- Use the brown target plate.

Features

-Compact and functional design

-Simple, self-explanatory menu selection and menu settings

-One-man, hand-held operation for speed of use

-Large display (can be illuminated)

-Memory function for constants

-Built-in calculator functions

-Pythagoras button for rapid calculation of building heights

-Switches off automatically

-The last three measured values remain in memory

-Built-in bubble level

-Tripod mounting threads

1. Product information

Display and control panel

Symbols displayed

Reference points on the tool

Front edge of the tool

Tripod thread axis

Rear edge of the tool

(standard setting)

End of the spike (e.g. for taking measurements from the corner of a room)

Mathematical functions

Addition

Subtraction

Multiplication

Pythagoras

Error messages

Signal received is too weak or too powerful.

Ambient light too bright

Contact a Hilti service department.

Operating temperature range of the tool is exceeded

Batteries almost discharged

Tracking (continuous measurement mode) activated

6

7

continued

Hilti P 20 Manual

1. Product information

 

1. Product information

Display and control panel, continued

 

Instructions at a glance

Button functions

Display

Select menu

Measure

Calculate

Switch on / off

2x

LASER

- - - - -

Recall last measured values (max. 3)

Scroll through active menu

Menu select / exit (rEF/CONSt/Light/ dELAY/bEEP/UNIT).

Recall last measured values (max. 3)

2.326 m

Scroll through active menu

 

Measure distance or start tracking

Addition

Subtraction

Multiplication

Pythagoras (calculates length of opposite side of right-angled triangle)

Start calculation or reset display

Switch tool on / off

8

9

continued

1. Product information

Instructions at a glance, continued

0.3 - 30 m:

30 - 100 m:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m/m2 /m3 ft in sq.ft /in

m

 

m

 

m

 

m

 

ft in

 

ft in

 

ft in

 

ft in

 

 

 

 

 

 

 

 

 

 

h!

s a

rEF

CONSt

0.000 ...

999.999 m

 

Light

OFF / ON / Auto

dELAY

0/2/5/10/20 s

bEEP

Auto/ON/OFF

UNIT

m / in / ft in

 

10

1. Product information

Technical data

Measuring range

0.3 to over 100 m*

Typical measuring range without target plate

Drywall panel, white

60 m

Concrete, dry

50 m

Brick, dry

50 m

*Maximum range depends on reflectance of the target surface and on the brightness of ambient light. If difficulty is experienced (no measurement possible), the Hilti PA411 target plate should be used.

Measuring time

0.5 to approx. 4 sec. in individual measurement mode

0.16 to approx. 1 sec. in continuous measurement mode (tracking)

Accuracy

± 3 mm individual measurement @ 23° C (± 0.1" individual measurement @ 73° F)

± 5 mm @ 0° C ... + 50° C

(± 0.2" @ + 32° F ... + 122° F)

± 7 mm @ - 10° C ... + 50° C (± 0.3" @ 14° F ... 122° F)

Beam diameter

<6 mm @ 10 m (< 0.2" @ 30 ft)

<30 mm @ 50 m (< 1.2" @ 150 ft)

<60 mm @ 100 m (< 2.4" @ 300 ft)

Operating modes

Individual measurement

Continuous measurement

Pre-set distance

Calculation

Operating status indicator

Liquid crystal display indicating individual operating modes and operating status

Laser Visible, 620 - 690 Nm, laser class 2 (IEC825-1), class II (FDA21 CFR) Power output: <1 mW

Power supply (3 V DC)

 

Battery type:

 

AA (LR6, AM3,

 

 

round cell R6)

Standard:

2 alkaline primary cells

Optional:

 

NiCd rechargeable

 

 

 

 

11

continued

 

1. Product information

 

1. Product information

Technical data, continued

Items supplied

 

 

Battery life at 25°

C [+ 77° F]

 

 

 

No. of measurements with a duration

1

2

PD20

 

of five seconds

 

 

 

Alkaline:

4000

 

 

 

NiCd:

2000

 

 

 

Battery condition

 

 

 

 

A warning is displayed when battery

 

 

 

voltage is low.

 

 

 

Operating temperature

3

 

 

- 10° C ... + 50° C (14° F ... 122 ° F)

 

 

 

Storage temperature

- 30° C ... + 70° C (- 22° F ... 158° F)

Protection class

Dust and splash-proof

IP 54 as per IEC 529 standard

4

Mounting points

1/4'’ Whitworth internal thread

One on the side and one underneath (Standard camera tripod thread)

Weight 380 g (without batteries)

Dimensions

165 x 67 x 47 mm (6.5'’ x 2.6'’ x 1.8'’)

Illustration showing dimensions [mm]

No.

Qty.

Designation

 

 

 

1

1

PD 20 laser range meter

2

1

Operating instructions

 

 

 

3

2

Batteries, type AA

4

1

Carrying case

 

 

 

12

13

2. Safety information

2. Safety information

Please read this now!

This information is intended to enable owners and users of the Hilti PD 20 to identify any operating risks in good time, i.e. to eliminate any such risks in advance where possible.

The owner of the tool must ensure that these instructions are understood and followed by all users.

Purpose

Intended uses

The Hilti PD 20 is intended for the following range of applications:

Measuring distances

Calculating areas, volumes and remote heights (side of right-angled triangle)

Addition and subtraction of distances

Examples of misuse

Use of the product without prior instruction

Use of the product outside its operating limits

Rendering safety devices ineffective or removing notices and warning signs

Opening the product unless expressly permitted in certain cases (e.g. to replace the batteries)

Making conversions or modifications to the product

The use of accessories from other manufacturers not explicitly approved by Hilti

The use of a product known to have been stolen

Deliberately dangerous or careless behaviour on scaffolding, when climbing ladders or when taking measurements in the vicinity of operating machinery or the exposed parts of machines or other equipment

Aiming the product directly at the sun

Deliberately dazzling other persons

2. Safety information

Intended use, continued

WARNING

Misuse may lead to injury, malfunction and damage to property. The owner must inform the user of the operating risks associated with the equipment and the corresponding safety precautions. The PD 20 laser range meter may be operated only when the user has received prior instruction.

Operating limits

See “Technical data” section.

Environment

The product is suitable for use in atmospheres permanently habitable by humans. It must not be used in corrosive or explosive environments. Exposure to rain for short periods during use is permissible.

Division of responsibilities

Responsibility of the manufacturer of the original equipment, Hilti Corporation,

FL 9494 Schaan (subsequently referred to as “Hilti”)

Hilti is responsible for supplying a technically safe product in faultless condition, including operating instructions and original accessories.

The responsibility of other manufacturers supplying accessories

The manufacturers of accessories (not supplied by Hilti) for the Hilti PD 20 are responsible for the development, implementation and communication of safety strategies for their products and the interaction of the latter with the Hilti product.

14

continued

15

continued

Loading...
+ 17 hidden pages