Hilti HVA Manual

4 (1)
Hilti HVA Manual

Adhesive Anchoring Systems

4.2.1 HVA Capsule Adhesive Anchor

4.2.1.4 Installation Instructions

HAS Rods,

HIS Inserts & Rebar

1.Set the drill depth gauge and drill a hole to the required hole depth.

Important: Clean out dust and debris. Use compressed air or vacuum at bottom of the hole. When using a Hilti matched tolerance diamond core bit, immediately remove standing water.

2.Insert appropriate diameter HVU adhesive capsule* into pre-drilled hole in base material.

Note: The best method for setting multiple capsules is to crush the first capsule(s) into the hole and then insert the next capsule. DO NOT cut off capsules partially protruding from the hole.

*Capsule length is longer than standard embed. depth and will protrude from the hole.

HAS Threaded Rods

3. Thread a HAS nut on the HAS rod. Place a washer on top of the first nut and then thread a black setting nut down on top of the washer. Tighten the two nuts together “locking” the washer between them. The top nut should be flush with the top of the rod.

HIS Internally

Threaded Inserts

3. Insert the shaft with socket into the hammer drill, screw the setting tool into the HIS and place in the socket.

Rebar

3. Rotate knurled locking sleeve and insert appropriate diameter rebar. End of rebar being inserted into base material must have a 45° cut or a 90° chisel point.

4.Insert a square drive shaft into the hammer drill and attach the proper impact socket. At the rotary hammer drill setting, engage the top nut of the HAS rod assembly with the socket and drive the rod down through the capsule(s). Stop drill rotation immediately upon reaching bottom of hole.

4.At the rotary hammer drill setting, drive the HIS down through the capsule(s). Stop drill

rotation immediately upon reaching bottom of hole.

4.Place chisel pointed end of rebar on top of HVU capsule and switch on hammer drill. Drill rebar down through the capsule(s). Stop drill rotation immediately upon reaching bottom of hole.

5.Do not disturb or load the set anchor before the specified curing time elapses.

5.Do not disturb or load the set anchor before the specified curing time elapses.

5.Do not disturb or load the set anchor before the specified curing time elapses.

102 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.ca.hilti.com I Product Technical Guide 2006