Electronic Monitoring Relays
True power monitoring
P1WM
True power monitor for 1- and 3-phase supplies for monitoring maximum true power values
Features
●Direct measurement of motors with a 2.2 kW (400 V) rating
●Output signal either latching or non-latching
●Adjustable reaction times
●Trip device if overload occurs
●Operates to normally energised or normally de-energised mode
●Suitable for current transformers
Technical Details |
P1WM |
|
|
|
|
Electrical data |
|
|
Measuring voltage = supply voltage |
3 AC/1 AC: 42, 110, 230, 400, 415, 500, |
|
|
550 VAC |
|
|
|
|
Tolerance |
85 ... 110 % |
|
|
|
|
Power consumption |
Approx. 5 VA |
|
|
|
|
Switching capability in accordance |
|
|
with EN 60947-4-1, 10/91 AC1: |
240 V/0.1 ... 5 A/1100 VA |
|
|
DC1: 24 V/0.1 ... 1 A/240 W |
|
|
|
|
Output contacts |
1 auxiliary contact (C/O) |
|
|
|
|
Contact fuse protection in accordance |
6 |
A quick or 4 A slow |
with EN 60947-5-1, 10/91 |
|
|
|
|
|
Max. switch-on current |
10 A AC |
|
Measuring circuit |
|
|
Adjustable measuring range limit values |
1 |
A version: 0...0.35; 0.25...0.7; 0.67...1 A |
|
5 |
A version: 0 ... 1; 1.1 ... 3; 3.3 ... 5 A |
|
|
|
Max. overload |
1 |
A version: 1.2 A, 6 A/max. 3 s |
|
5 |
A version: 6 A, 25 A/max. 3 s |
Response delay |
1A version: 0.25 ... 3 s adjustable |
|
|
5 |
A version: 0.25 ... 30 s adjustable |
|
|
|
Start-up suppression time |
0.5 ... 20 s adjustable |
|
|
|
|
Requirement for current transformer |
1 A version: 1.5 ... 7.5 VA |
|
|
5 |
A version: 2.5 ... 15 VA |
Mechanical data |
|
|
Max. cable cross section |
2 x 2.5 mm2 |
|
of external conductor |
Single-core or multi-core with crimp |
|
|
connector |
|
|
|
|
Torque setting for connection terminals |
1.2 Nm (screws) |
|
Dimensions (H x W x D) |
75 x 90 x 115 mm |
|
|
|
|
Weight |
470 g |
|
|
|
|
Description
The P1WM true power monitor is enclosed in a 90 mm wide P-75 housing. All three external conductors are used as the supply voltage. There are 7 versions available for use with 3-phase AC voltage supplies.
Features:
●Relay output: 1 auxiliary contact (C/O)
●2 versions with adjustable measuring ranges up to max. 1 A or up to max. 5 A
●Overload switching points
●Adjustable response delay
●Adjustable start-up suppression time
●Automatic or manual reset
●LED-display for supply voltage and switching status of the auxiliary contacts Pmax
The P1WM monitors whether true power exceeds a defined level in AC or 3-phase current loads. The signal, which is proportional to the true power, is derived by multiplying the voltage and current. The maximum permitted true power Pmax is set using a potentiometer. If the measured true power PW exceeds the preset value Pmax, the output relay K1 switches and the red LED will be on.
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland |
NSG-D-2-253-10/00 |
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de |
|
Electronic Monitoring Relays
True power monitoring
P1WM
Internal wiring diagram
L1 |
k |
|
|
Pmax |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IM |
IM |
|
|
|
|
|
|
12 |
14 |
|
UL1 |
|
|
|
|
|
|
||
|
|
P |
|
DPmax |
|
|
|
|
|
|
Iint |
UL1 * Iint * cos j* k |
& Pmax - PW |
& |
tr |
K1 |
|
||
|
|
|
|
||||||
|
n * IM Iint |
|
|
|
|
|
|
11 |
|
U(I) Y1 Y2 |
ta |
|
|
|
Control logic |
Y3 |
|
||
|
|
|
|
|
|
Y4 |
|
||
|
|
|
|
|
|
|
|
|
|
L1 |
|
+ |
|
|
|
|
|
Y5 |
|
|
|
|
|
|
|
|
|
||
L2 |
Power supply |
|
|
|
|
|
|
|
|
L3 |
|
0 |
|
|
|
|
|
|
|
V W |
|
N |
|
|
|
|
|
|
|
IM |
Measuring currents |
|
|
|
|
|
cos j Power factor |
PW |
True power |
|||||||||||||
n |
Measuring range factor |
|
|
|
|
|
k |
Correction factor |
Pmax |
Max. True power |
||||||||||||
UL1 |
Measuring voltages |
|
|
|
|
|
ta |
Start-up suppression time |
tr |
Response delay |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Timing diagram |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Measuring circuit |
Pmax |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pmin |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
voltage UB |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Output Pmax (K1, RB) |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output Pmax (K1, AB) |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
t a |
|
|
|
|
t r |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
PW > Pmax |
|
|
|
|
|
|||||
RB |
Normally energised mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
IM |
Measuring current |
n |
Measuring range factor |
||||||||||||||
AB |
Normally de-energised mode |
|
Iint |
Internal measuring current |
ta |
Start-up suppression time |
||||||||||||||||
Pmax |
Response value, overload |
|
|
|
|
|
cos j Power factor |
tr |
Response delay |
|||||||||||||
UL1 |
Measuring voltage at L1 |
|
|
|
|
|
k |
Correction factor |
|
|
|
|
|
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland |
NSG-D-2-253-10/00 |
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de |
|