Panasonic DMC-XS1EB, DMC-XS1EE, DMC-XS1EF, DMC-XS1EG, DMC-XS1EP User Manual

...
0 (0)

ORDER NO. DSC1302004CE

B26

Digital Camera

Model No. DMC-XS1P

DMC-XS1PC

DMC-XS1PU

DMC-XS1EB

DMC-XS1EE

DMC-XS1EF

DMC-XS1EG

DMC-XS1EP

DMC-XS1GA

DMC-XS1GC

DMC-XS1GF

DMC-XS1GK

DMC-XS1GN

DMC-XS1GT

Colour

 

(W)..........

White Type

(K)...........

Black Type

(R)...........

Red Type (except PC)

(WA)........

White Type (only EB/EG/EP)

(V)............

Violet Type (only EB/EF/EG/EP/GC/GF/GN)

© Panasonic Corporation 2013 Unauthorized copying and distribution is a violation of law.

TABLE OF CONTENTS

 

PAGE

PAGE

1

Safety Precautions -----------------------------------------------

3

 

 

1.1. General Guidelines ----------------------------------------

3

 

 

1.2. Leakage Current Cold Check ---------------------------

3

 

 

1.3. Leakage Current Hot Check (See Figure. 1)--------

3

 

 

1.4. How to Discharge the E.Capacitor on Flash

 

 

 

Top P.C.B. ----------------------------------------------------

4

 

2

Warning --------------------------------------------------------------

5

 

 

2.1. Prevention of Electrostatic Discharge (ESD)

 

 

 

to Electrostatically Sensitive (ES) Devices ----------

5

 

 

2.2. How to Recycle the Lithium Ion Battery (U.S.

 

 

 

Only)-----------------------------------------------------------

5

 

3

Service Navigation------------------------------------------------

6

 

 

3.1. Introduction --------------------------------------------------

6

 

 

3.2. Important Notice -------------------------------------------

6

 

 

3.3. General Description About Lead Free Solder

 

 

 

(PbF) ----------------------------------------------------------

7

 

 

3.4. How to Define the Model Suffix (NTSC or PAL

 

 

 

model)---------------------------------------------------------

8

 

4

Specifications ----------------------------------------------------

12

 

5

Location of Controls and Components------------------

13

 

6

Service Mode -----------------------------------------------------

15

 

 

6.1. Error Code Memory Function -------------------------

15

 

7

Service Fixture & Tools ---------------------------------------

18

 

 

7.1. Service Fixture and Tools ------------------------------

18

 

 

7.2. When Replacing the Main P.C.B. --------------------

18

 

 

7.3. Service Position ------------------------------------------

19

 

8

Disassembly and Assembly Instructions---------------

20

 

 

8.1. Disassembly Flow Chart--------------------------------

20

 

 

8.2. P.C.B. Location -------------------------------------------

20

 

 

8.3. Disassembly Procedure --------------------------------

21

 

 

8.4. Removal of the CCD FPC Unit -----------------------

28

 

9

Measurements and Adjustments --------------------------

29

 

 

9.1. Introduction ------------------------------------------------

29

 

 

9.2. Before Disassembling the unit ------------------------

29

 

 

9.3. Details of Electrical Adjustment-----------------------

31

 

 

9.4. After Adjustment------------------------------------------

35

 

10

Maintenance ------------------------------------------------------

36

 

 

10.1. Cleaning Lens and LCD Panel -----------------------

36

 

11

Block Diagram ---------------------------------------------------

37

 

 

11.1. Overall Block Diagram ----------------------------------

37

 

 

11.2. Flash / Top Block Diagram-----------------------------

38

 

 

11.3. Sub Operation Block Diagram ------------------------

38

 

12

Wiring Connection Diagram ---------------------------------

39

 

 

12.1. Interconnection Diagram -------------------------------

39

 

2

1 Safety Precautions

1.1.General Guidelines

1.IMPORTANT SAFETY NOTICE

There are special components used in this equipment which are important for safety. These parts are marked by

in the Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not modify the original design without permission of manufacturer.

2.An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during servicing.

3.When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.

4.After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.

5.After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.

1.2.Leakage Current Cold Check

1.Unplug the AC cord and connect a jumper between the two prongs on the plug.

2.Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading should be between 1 MΩ and 5.2 MΩ. When the exposed metal does not have a return path to the chassis, the reading must be infinity.

1.3.Leakage Current Hot Check

(See Figure. 1)

1.Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.

2.Connect a 1.5 kΩ, 10 W resistor, in parallel with a 0.15 μF capacitor, between each exposed metallic part on the set and a good earth ground, as shown in Figure. 1.

3.Use an AC voltmeter, with 1 kΩ/V or more sensitivity, to measure the potential across the resistor.

4.Check each exposed metallic part, and measure the voltage at each point.

5.Reverse the AC plug in the AC outlet and repeat each of the above measurements.

6.The potential at any point should not exceed 0.75 V RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 mA. In case a measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer.

Figure. 1

3

1.4.How to Discharge the E.Capacitor on Flash Top P.C.B.

CAUTION:

Be sure to discharge the E.Capacitor on Flash Top P.C.B. before disassembling.

Be careful of the high voltage circuit on Flash Top P.C.B. when servicing.

[Discharging Procedure]

1.Put the insulation tube on the lead part of resistor (ERG5SJ102:1kΩ /5W). (An equivalent type of resistor may be used.)

2.Put the resistor between both terminals of E.Capacitor on the Flash Top P.C.B. for approx. 5 seconds.

3.After discharging, confirm that the E.Capacitor voltage is lower than 10V by using a voltmeter.

Fig. F1

4

2 Warning

2.1.Prevention of Electrostatic Discharge (ESD) to Electrostatically

Sensitive (ES) Devices

Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices.

The following techniques should be used to help reduce the incidence of component damage caused by electrostatic discharge (ESD).

1.Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap, which should be removed for potential shock reasons prior to applying power to the unit under test.

2.After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.

3.Use only a grounded-tip soldering iron to solder or unsolder ES devices.

4.Use only an antistatic solder removal device. Some solder removal devices not classified as “antistatic (ESD protected)” can generate electrical charge sufficient to damage ES devices.

5.Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.

6.Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material).

7.Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circuit assembly into which the device will be installed.

CAUTION :

Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.

8.Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD) sufficient to damage an ES device).

2.2.How to Recycle the Lithium Ion Battery (U.S. Only)

5

3 Service Navigation

3.1.Introduction

This service manual contains technical information, which allow service personnel’s to understand and service this model. Please place orders using the parts list and not the drawing reference numbers.

If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.

3.2.Important Notice

3.2.1. CCD FPC UNIT:

• The image sensor (CCD FPC) unit which are connected to the lens unit with 3 screws. These screws are adjusted for the Optical tilt.

During servicing, if one of CCD FPC fixing screws are loosened, the Optical tilt adjustment must be performed. About the Optical tilt adjustment, refer to the “9.3.2. Adjustment Specifications” for details.

3.2.2. P.C.B.:

• In order to remove Main P.C.B., it is necessary to remove the solder (3 points) of the battery terminal. It is judged that the analysis of the Main P.C.B. which the battery terminal separated is difficult.

So the Main P.C.B. is unit exchange.

Please fix individually about the Flash Top P.C.B..

3.2.3. LENS UNIT:

The minimum replacement part size of the Lens part is as shown below.

When servicing, replace the following numbered replacement part size as the smallest size.

3.2.4.About Flexible Cable and Connector

Do not touch carelessly so that the foreign body should not adhere to the terminal part of flexible cable and connector. Wipe off with a clean cloth and the cotton bud, etc. when the terminal part is dirty.

6

3.3.General Description About Lead Free Solder (PbF)

The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used for this equipment in considering the globally environmental conservation.

The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin (Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30°C (86°F) more than that of the normal solder.

Distinction of P.C.B. Lead Free Solder being used

Service caution for repair work using Lead Free Solder (PbF)

The lead free solder has to be used when repairing the equipment for which the lead free solder is used. (Definition: The letter of “PbF” is printed on the P.C.B. using the lead free solder.)

To put lead free solder, it should be well molten and mixed with the original lead free solder.

Remove the remaining lead free solder on the P.C.B. cleanly for soldering of the new IC.

Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt the lead free solder.

Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30°C (662±86°F).

Recommended Lead Free Solder (Service Parts Route.)

The following 3 types of lead free solder are available through the service parts route. RFKZ03D01KS-----------(0.3mm 100g Reel)

RFKZ06D01KS-----------(0.6mm 100g Reel) RFKZ10D01KS-----------(1.0mm 100g Reel)

Note

* Ingredient: tin (Sn) 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%

7

3.4.How to Define the Model Suffix (NTSC or PAL model)

There are seven kinds of DMC-XS1, regardless of the colours.

a) DMC-XS1 (Japan domestic model)

b) DMC-XS1P/PC

c) DMC-XS1EB/EF/EG/EP

d) DMC-XS1EE

e) DMC-XS1GT

f) DMC-XS1GN

g) DMC-XS1PU/GA/GC/GF/GK

What is the difference is that the “INITIAL SETTINGS” data which is stored in Flash-ROM mounted on Main P.C.B..

3.4.1.Defining methods:

To define the model suffix to be serviced, refer to the nameplate which is putted on the bottom side of the Unit.

NOTE:

After replacing the Main P.C.B., be sure to achieve adjustment.

The service software is available at “TSN Website”.

8

3.4.2.INITIAL SETTINGS:

After replacing the Main P.C.B., make sure to perform the initial settings after achieving the adjustment by ordering the following procedure in accordance with model suffix of the unit.

1. IMPORTANT NOTICE:

Before proceeding Initial settings, make sure to read the following CAUTIONS.

2.PROCEDURES:

Precautions: Read the above “CAUTION 1” and “CAUTION 2”, carefully.

Preparation:

-Attach the Battery.

(Since this unit has built-in memory, it can be performed without inserting memory card.)

1.Turn the Power on.

2.Press the [ MODE ] button, and select the [ NORMAL PICTURE ] mode by Cursor buttons, then press the [ MENU/SET ] button.

3.Turn the Power off.

(If the unit is other than [ NORMAL PICTURE ] mode, it does not display the initial settings menu.)

Step 1. The temporary cancellation of “INITIAL SETTINGS”:

Press the [ PLAYBACK ] button, “[ UP ] of Cursor button” and “[ W ] side of Zoom button” simultaneously, turn the Power on.

Step 2. The cancellation of “INITIAL SETTINGS”:

Press the [ PLAYBACK ] button in order to enter the [ PLAYBACK ] mode.

Press the [ MENU/SET ] button and “[ LEFT ] of Cursor button” simultaneously, turn the Power off. The LCD displays the “ ! ” mark before the unit powers down.

Step 3. Turn the Power on:

Turn the Power on.

9

Step 4. Display the INITIAL SETTING:

While pressing [ MENU/SET ] button and “[ RIGHT ] of Cursor button” simultaneously, turn the Power off. The “INITIAL SETTINGS” menu is displayed.

There are two kinds of “INITIAL SETTINGS” menu form as follows:

[CASE 1. After replacing Main P.C.B.]

When Main P.C.B. has just been replaced, all of the model suffix is displayed as follows. (Five pages in total)

[CASE 2. Other than “After replacing Main P.C.B.”]

Step 5. Choose the model suffix in “INITIAL SETTINGS”: (Refer to “CAUTION 1”)

[Caution: After replacing Main P.C.B.]

The model suffix can been chosen, JUST ONE TIME.

Once one of the model suffix have been chosen, the model suffix lists will not be displayed, thus, it can not be changed. Therefore, select the area carefully.

Select the area with pressing “[ UP ] / [ DOWN ] of Cursor buttons”.

10

Step 6. Set the model suffix in “INITIAL SETTINGS”:

Press the “[ RIGHT ] of Cursor buttons”.

The only set area is displayed, and then press the “[ RIGHT ] of Cursor buttons” after confirmation. (The unit is powered off automatically.)

Step 7. CONFIRMATION:

Confirm the display of “PLEASE SET THE CLOCK” in concerned language when the unit is turned on again. When the unit is connected to PC with USB cable, it is detected as removable media.

(When the “GK” or “GT” model suffix is selected, the display shows “PLEASE SET THE CLOCK” in Chinese.)

1)As for your reference, major default setting condition is as shown in the following table.

Default setting (After “INITIAL SETTINGS”)

 

MODEL

VIDEO OUTPUT

LANGUAGE

DATE

REMARKS

a)

DMC-XS1(Japan domestic model)

NTSC

Japanese

Year/Month/Date

 

b)

DMC-XS1P

NTSC

English

Month/Date/Year

 

c)

DMC-XS1PC

NTSC

English

Month/Date/Year

 

d)

DMC-XS1PU

NTSC

Spanish

Month/Date/Year

 

e)

DMC-XS1EB

PAL

English

Date/Month/Year

 

f)

DMC-XS1EE

PAL

Russian

Date/Month/Year

 

g)

DMC-XS1EF

PAL

French

Date/Month/Year

 

h)

DMC-XS1EG

PAL

English

Date/Month/Year

 

i)

DMC-XS1EP

PAL

English

Date/Month/Year

 

j)

DMC-XS1GA

PAL

English

Date/Month/Year

 

k)

DMC-XS1GC

PAL

English

Date/Month/Year

 

l)

DMC-XS1GF

PAL

English

Date/Month/Year

 

m)

DMC-XS1GK

PAL

Chinese (simplified)

Year/Month/Date

 

n)

DMC-XS1GN

PAL

English

Date/Month/Year

 

o)

DMC-XS1GT

NTSC

Chinese (traditional)

Year/Month/Date

 

11

Panasonic DMC-XS1EB, DMC-XS1EE, DMC-XS1EF, DMC-XS1EG, DMC-XS1EP User Manual

4 Specifications

The following specification is for DMC-XS1P/DMC-FH10P. Some specifications may differ depending on model suffix.

12