Siemens SGT-400 User Manual

4.8 (18)
Siemens SGT-400 User Manual

SGT-400 Industrial Gas Turbine

Power Generation: (ISO) 12.90 MW(e)

The SGT-400 combines very high efficiency (nominal 35 %) with excellent emissions performance in a rugged industrial design. This makes it the ideal choice for a wide variety of power generation applications.

The Siemens twin-shaft industrial gas turbine SGT-400 features a compact gas generator and a two-stage power turbine, incorporating the latest aerodynamic and combustion technologies. The turbine has a simple-cycle efficiency of nominally 35 %.

For industrial cogeneration, the high steam-raising capability of more than 27 tonnes per hour contributes towards achieving overall plant efficiencies of 80 % or higher. In addition, the compact arrangement, on-site maintainability and inherent reliability of the SGT-400 have made it an ideal gas turbine for the demanding oil and gas industry.

Incorporating proven gas turbine technology, the SGT-400 offers costeffective power for a wide range of duties, including:

Industrial Power Generation

Simple-cycle and combined-cycle power plants for base load, standby power and peak lopping

Cogeneration for industrial plants with high heat load and district heating schemes

Power Generation in the Oil and Gas Industry

Offshore: on oil platforms and FPSO (Floating Production, Storage & Offloading) vessels

Onshore: for oil field service, refinery application, emergency and standby power generation,

Including highly efficient cogeneration solutions for oil and gas applications

Industrial Gas Turbines

Answers for energy.

SGT-400 Industrial

Gas Turbine

Technical specifications

Overview

Twin-shaft, industrial

Power generation: 12.90MW(e)

Frequency: 50 or 60Hz

Electrical efficiency: 34.8%

Heat rate: 10,355kJ/kWh

(9,815 Btu/kWh)

Compressor pressure ratio: 16.8:1

Exhaust gas flow: 39.4kg/s (86.8lb/s)

Exhaust temperature: 555°C (1,031°F)

Typical emissions: NOx <15 ppmV and CO <10 ppmV (corrected to 15 % O2 dry)

Medium-calorific value fuels capability (>25MJ/Nm3 Wobbe index)

Axial Compressor

11-stage with variable inlet guide vanes

Air flow: (ISO) 38.9kg/s

Nominal speed: 14,100rpm

Combustion

6 reverse-flow cannular combustion chambers

Dry Low Emissions (DLE) system

High-energy ignitor system

Turbine

2-stage overhung compressor turbine

-Both stages are air-cooled

2-stage high-efficiency power turbine

-Rotor blades have interlocking shrouds for mechanical integrity

Bearings

Tilt-pad radial and thrust

Standard vibrationand temperaturemonitoring

Main reduction gearbox

• Speeds of 1,500rpm and 1,800rpm

Generator

Voltages: 6 to 13.8kV

Frequency: 50 or 60Hz

Package

Fabricated steel underbase

-Integral oil tank

-Multi-point mounting

-Optional 3-point mounting

Modular fluid systems incorporating:

-Lubricating oil system

-Auxiliary gearbox-driven main pump

-AC motor-driven auxiliary pump

-DC motor-driven emergency pump

Oil cooler and oil heater

Electrically driven hydraulic start system

Hydrocarbon drains tank on package

Control system

-Siemens SIMATIC PLC-based with distributed control and processing capability installed on package

-Optional Allen-Bradley system

-Optional off-package systems

Vibration monitoring system

-BN1701: Standard

-BN3500: Optional

Fire and gas detection equipment

Fire suppression equipment

Onand off-line compressor cleaning options available

Combustion-air inlet-filtration options:

-Simple static

-Pulse cleaning

-HEPA

Enclosure

-Painted carbon steel or stainless steel

-Noise level options (85 dB(A) standard)

SGT-400 core engine test facility.

Gas turbine

Key features

High simple-cycle and cogeneration efficiencies, cutting fuel costs

Dual-fuel Dry Low Emissions (DLE) combustion system, meeting stringent legislation

Twin-shaft arrangement for both power generation and mechanical drive, allowing commonality of parts in mixed duty installations

Maintenance

Site maintainability or optional rapid core exchange as required by customer

Designed for maintenance:

-Horizontally split compressor casing

-Horizontally and vertically split inlet casing

-Combustion chambers, flame tubes and ignitors easily accessible for inspection

-Large side-doors on enclosure for equipment change-out

-Gas generator and power turbine removal on either side of package

Multiple boroscope-inspection ports