Panasonic cs-xe9skua, cs-xe12skua Operation Manual

0 (0)

Operating Instructions

Air Conditioner

Model No.

 

Indoor Unit

Outdoor Unit

CS-XE9SKUA

CU-XE9SKUA

CS-XE12SKUA

CU-XE12SKUA

Operating Instructions

2-14

Air Conditioner

 

Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached.

Before operating the unit, please read these operating instructions thoroughly and keep them for future reference.

English

Instructions d’utilisation

15-27

Climatiseur

 

Merci d’avoir acheté un climatiseur Panasonic. Instructions d’installation en annexe.

Avant d’utiliser l’appareil, veuillez lire ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.

Français

ACXF55-01820

Provide maximum comfort,

clean air and optimize energy saving

ECONAVI and AUTO COMFORT The Right Choice for Energy Saving

Equipped with the human activity sensor, the air conditioner ensures to deliver cool or warm air to you, and keeps the room consistently comfortable with minimum energy consumption.

See “To learn more...” for details.

ROOM FREEZE PROTECTION FUNCTION (RFP)

Used in spaces that are unoccupied during the winter, for the purpose of protecting any equipment or appliances which may be destroyed as a result of freezing temperature.

2

Quick guide

1

2

3

Inserting the batteries

1Pull out the back cover of remote control

2Insert AAA or R03 batteries (can be used ~ 1 year)

3Close the cover

 

2

3

Clock setting

TIMER

 

 

1

Press CLOCK

ON

 

SET

1

2

3

2

Set the time

OFF

 

CANCEL

1

 

AC RC

3

Confirm

SET CHECK CLOCK

RESET

 

 

Basic operation

AIR CONDITIONER

MODE

2

ECONAVI

 

AUTO

OFF/ON

COMFORT

1

MODE

 

RFP

3

 

TEMP

 

POWERFUL/

 

AIR SWING

 

QUIET

 

 

 

 

 

 

FAN SPEED

 

 

TIMER

 

 

 

ON

 

SET

 

1

2

3

 

OFF

 

CANCEL

 

 

 

AC RC

 

SET CHECK

CLOCK

RESET

26ft/8m

1 Select the desired mode

AUTO HEAT

FANDRY COOL 2 Start/stop the operation

POWER

Please note that the indication is on display to start the unit.

3Select the desired temperature

Selection range (Not applicable for FAN mode):

60°F ~ 86°F / 16°C ~ 30°C.

Operating the unit within the recommended temperature range may save energy.

HEAT : 68°F ~ 75°F / 20°C ~ 24°C. COOL : 78°F ~ 82°F / 26°C ~ 28°C. DRY : 2°F ~ 4°F / 1°C ~ 2°C

lower than room temperature.

To dim or restore the unit’s indicator

brightness, press and hold for 5 seconds.

Use remote control within 26ft/8m from the remote control receiver of the indoor unit.

The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject to change without notice for future improvement.

Table of contents

 

Safety precautions...................

4-5

How to use...............................

6-7

To learn more... ......................

8-9

Cleaning instructions ................

10

Troubleshooting ..................

11-12

Information................................

13

Accessories

Remote control

AAA or R03 batteries × 2

Remote control holder

Screws for remote control holder × 2

English

3

Panasonic cs-xe9skua, cs-xe12skua Operation Manual

Safety precautions

To prevent personal injury, injury to others or property damage, please comply with the following:

Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below:

This sign warns of WARNING death or serious

injury.

This sign warns of CAUTION injury or damage to

property.

The instructions to be followed are classified by the following symbols:

This symbol denotes an action that is PROHIBITED.

These symbols denote actions COMPULSORY.

Power supply

Indoor unit Air inlet

Air outlet

Remote control

Air inlet

Outdoor unit Air outlet

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.

Confirm with authorised dealer or specialist on usage of any specified refrigerant type.

Using refrigerant type other than the specified may cause product damage, burst and injury etc.

Do not install the unit in a potentially explosive or flammable atmosphere. Failure to do so could result in fire.

Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.

Do not touch the outdoor unit during lightning, it may cause electric shock.

Do not expose yourself directly to cold air for a long period to avoid excess cooling.

Do not sit or step on the unit, you may fall down accidentally.

Remote control

Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.

Power supply

Do not use a modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.

4

To prevent overheating, fire or electric shock:

Do not share the same power outlet with other equipment.

Do not operate with wet hands.

Do not over bend the power supply cord.

If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard.

It is strongly recommended to install this unit using an Earth Leakage Circuit Breaker

(ELCB) or Ground Fault Interrupt (GFCI) or Appliance Leakage Current Interrupt (ALCI) to prevent electric shock or fire.

Stop using the product if any abnormality/ failure occurs or turn off the power switch and breaker. (Risk of smoke/fire/electric shock)

Examples of abnormality/failure

The ELCB or GFCI or ALCI trip frequently.

Burning smell is observed.

Abnormal noise or vibration of the unit is observed.

Water leaks from the indoor unit.

Power cord becomes abnormally hot.

Fan speed cannot be controlled.

The unit stops running immediately even if it is switched on for operation.

The fan does not stop even if the operation is stopped.

Contact your local dealer immediately for maintenance or repair assistance.

This equipment must be earthed to prevent electrical shock or fire.

Prevent electric shock by switching off the

power supply:

- Before cleaning or servicing,

-When extended non-use, or

-During abnormally strong lightning activity.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzene, thinner or scouring powder to avoid damage or corrosion at the unit.

Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.

Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation.

Do not expose plants or pet directly to airflow to avoid injury, etc.

Do not touch the sharp aluminium fin, sharp parts may cause injury.

Do not switch ON the indoor unit when waxing the floor. After waxing, aerate the room properly before operating the unit.

Do not install the unit in oily and smoky areas to prevent damage to the unit.

Do not dismantle the unit for cleaning purpose to avoid injury.

Do not step onto an unstable bench when cleaning the unit to avoid injury.

Do not place a vase or water container on the unit. Water may enter the unit and degrade the insulation. This may cause an electric shock.

 

Do not open window or door for long time

precautions

 

- Connected properly,

 

during COOL/DRY mode operation.

 

 

Prevent water leakage by ensuring drainage

 

 

pipe is:

 

 

- Kept clear of gutters and containers, or

Safety

 

- Not immersed in water

 

 

 

After a long period of use or use with any

 

 

combustible equipment, aerate the room

 

 

regularly.

 

 

After a long period of use, make sure the

English

 

installation rack does not deteriorate to

 

prevent the unit from falling down.

 

 

Remote control

Do not use rechargeable (Ni-Cd) batteries. It may damage the remote control.

To prevent malfunction or damage of the remote control:

Remove the batteries if the unit is not going to be used for a long period of time.

New batteries of the same type must be inserted following the polarity stated.

5

How to use

POWER

TIMER

AUTO COMFORT

RFP

POWERFUL

QUIET

 

(Green)

(Orange)

(Green)

(Green)

(Orange)

(Orange)

(Green)

 

 

 

 

 

 

Indicator

ECONAVI

To optimize energy saving

MODE To select operation mode

AUTO - For your convenience

HEAT

- To enjoy warm air

COOL - To enjoy cool air

DRY

- To dehumidify the environment

FAN

- To circulate air in the room

POWERFUL/QUIET To switch between

powerful & quiet

POWERFUL QUIET NORMAL

POWERFUL: To reach temperature quickly

POWERFUL

This operation stops automatically after 20 minutes.

QUIET: To enjoy quiet operation

QUIET

• This operation reduces airflow noise.

Auto OFF/ON button

Human activity

sensor

Remote control display

AIR CONDITIONER

MODE

AUTO ECONAVI OFF/ON COMFORT

MODE RFP

TEMP

POWERFUL/

 

AIR SWING

QUIET

 

 

 

 

 

FAN SPEED

 

 

TIMER

 

 

 

ON

 

 

SET

1

2

 

3

OFF

 

CANCEL

 

 

AC

RC

SET CHECK

CLOCK

RESET

Remote control receiver

Press and hold for approximately

10 seconds to show temperature setting in °F or °C.

Press and hold for approximately

5 seconds to show

12-hour (am/pm) or

24-hour time indication.

Press to restore the remote control to default setting.

Not used in normal operations.

FAN SPEED To select fan speed

(Remote control display)

AUTO

FAN

For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.

AUTO

OFF/ON

Use when remote control is misplaced or a malfunction occurs. Raise the front panel:

1.Press the button once to use in AUTO mode.

2.Press and hold the button until you hear 1 beep, then release to use in forced COOL mode.

3.Repeat step 2. Press and hold the button until you hear 2 beeps, then release to use in normal COOL mode.

4.Repeat step 3. Press and hold the button until you hear 3 beeps, then release to use in forced HEAT mode.

• Press the button again to turn off.

6

See “To learn more...” for details.

AUTO

COMFORT To maximize comfort

AUTO COMFORT

RFP To select Room Freeze

Protection

RFP

When selected, the unit will circulate the air in High mode for monitoring the temperature. When the sensor detects the temperature drops below 46°F / 8°C the compressor/heat pump operation begins, when the temperature reaches 50°F / 10°C, the compressor stops and repeat this cycle.

AIR SWING To adjust airflow direction

(Remote control display)

Keeps the room ventilated.

In COOL/DRY mode, if AUTO is set, the flap swings left/right and up/down automatically.

In HEAT mode, if AUTO is set, the horizontal flap is fixed at the predetermined position.

The vertical flap swings left/right after the temperature rises.

Do not adjust the flap by hand.

Auto Restart Control

If power is resumed after a power failure, the operation will restart automatically after a period of time with previous operation mode and airflow direction.

This control is not applicable when TIMER is set.

To set the timer

2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times.

1 2 3

TIMER

ON SET

1 2 3

OFF CANCEL

1

Select ON or OFF

Example:

 

timer

OFF at 22:00

 

• Each time pressed:

OFF

 

Cancel

 

2

Set the time

 

 

 

2

3

Confirm

SET

 

 

 

 

 

 

 

 

 

TIMER

 

 

 

• To cancel ON or OFF timer, press ON

or

OFF

use

to select respective

or

then press

CANCEL .

• If timer is cancelled manually or due to power

to

How

failure, you can restore the timer again by

 

 

 

pressing ON

or OFF

to select respective

or

 

then press

SET .

 

 

 

 

 

• The nearest timer setting will be displayed and

 

will activate in sequence.

 

 

 

English

• When ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.

• Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Quick guide.

Note

POWERFUL/ AUTO

ECONAVI QUIET COMFORT

, ,

• Can be activated in all modes and can be cancelled by pressing the respective button again.

• Cannot be selected at the same time.

7

To learn more...

Operation mode

AUTO : During operation mode selection the POWER indicator blinks.

• Unit selects operation mode every 10 minutes according to setting temperature and room temperature. HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation.

COOL : Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.

DRY

: Unit operates at low fan speed to give a gentle cooling operation.

FAN

: To circulate air in the room.

ECONAVI and AUTO COMFORT

 

 

AUTO

 

 

ECONAVI

or

COMFORT

 

Note

 

 

 

 

 

 

 

AIR SWING When manual AIR SWING is selected,

The unit will start to initialize

The human activity sensor

the ECONAVI and AUTO COMFORT

operations will be cancelled.

(for approximately 1 minute)

will start to detect.

Human activity sensor operation

ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.

Mode

Human

Low activity

Normal activity

High activity

Absent

COOL/DRY

 

 

 

 

+4°F /

Set

+2°F / +1°C

 

 

+2°C

 

 

 

 

 

 

 

 

 

HEAT

temperature

 

 

 

-4°F /

 

 

 

-4°F / -2°C

 

 

 

 

-2°C

 

 

 

 

 

AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human comfortable consistently.

Mode

Human

Low activity

Normal activity

High activity

Absent

 

 

 

 

 

+4°F /

 

Set

+2°F / +1°C

 

 

+2°C

COOL/DRY

+0.5°F / +0.3°C

 

 

 

temperature

 

 

-2°F / -1°C

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

-4°F / -2°C

-4°F /

Set

+1 tap*

 

+1 tap

-2°C

 

 

0HGLXP )DQ

 

Fan Speed

 

 

 

 

 

 

 

 

*During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.

**During human absence, maximum fan speed for COOL/DRY mode is medium fan.

The human activity sensor will also scan for area of heat source and movement in a room.

Detection area

The human activity sensor performance is influenced by indoor unit location, movement speed, temperature range, etc.

The human activity sensor may:

-mistakenly detect an object with heat source & movement similar to human, such as pets, etc.

-mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.

Do not place large objects near the sensor and keep away heating units or humidifier from the sensor’s detection area. They may cause sensor malfunction.

120º

23ft/7m

8

Room Freeze Protection Function (RFP)

Room Freeze Protection function (RFP) is used in spaces that are unoccupied during the winter, for the purpose of protecting any equipment or appliances which may be destroyed as a result of freezing temperature.

To select Room Freeze Protection

When selected, the unit will circulate the air in High mode for monitoring the temperature. When the sensor detects the temperature drops below 46°F / 8°C the compressor/heat pump operation begins, when the temperature reaches 50°F / 10°C, the compressor stops and repeat this cycle.

ROOM FREEZE PROTECTION FUNCTION (RFP) OPERATION

When the RFP is selected, the unit will operate the fan at high speed for proper room temperature monitoring. When the sensor detects that the room temperature has dropped below 46°F / 8°C, the compressor/heat pump operation begins. When the room temperature reaches 50°F / 10°C, the unit shuts off, then will repeat continuously if the temperature drops below 46°F / 8°C again.

<Disclaimer>

This function may not be performed if the unit is not energized, or under a certain condition that unit is unable to operate such as in protection mode. Please consult with the HVAC installers or professional for details.

The Room Freeze Protection function (RFP) cannot be used unless the unit is energized and set into the RFP mode. In the advent of a power failure this mode will not function. During the RFP mode, POWERFUL OPERATION, QUIET OPERATION and FAN SPEED selection are all disabled. Please consult with you HVAC installer or professional for more details.

Operation conditions

Use this air conditioner under the following temperature range.

DBT : Dry bulb temperature WBT : Wet bulb temperature

Temperature (°F/°C)

Indoor

Outdoor

DBT

WBT

DBT

WBT

 

 

COOL

Max.

89.6/32

73.4/23

114.8/46

78.8/26

Min.

60.8/16

51.8/11

0/-17.8

-/-

 

HEAT

Max.

86.0/30

-/-

75.2/24

64.4/18

Min.

60.8/16

-/-

-15/-26

-2.2/-19

 

Power Supply

Models Number

Time Delay Circuit Breaker

Rated Volts

CS-XE9SKUA / CU-XE9SKUA

15 Amps

208/230V

CS-XE12SKUA / CU-XE12SKUA

20 Amps

 

English To learn more...

9

Loading...
+ 19 hidden pages