Operating Instructions Air Conditioner

Before operating the unit, please read these operating instructions thoroughly and keep them for future reference. The included Installation Instructions should be kept and read by the installer before installation.

Remote control is packaged in the indoor unit and removed by the installer before installation.

English

ACXF55-22380

Provides maximum comfort and clean air with optimal energy saving methods.

Use remote control within 8 m from the remote control receiver of the indoor unit.

 

Quick Guide

B

Inserting the batteries

 

 

1

 

 

2

 

 

3

 

1

Pull out the back cover

 

A

of remote control.

 

2

Insert AAA or R03

 

 

batteries.

 

3

Close the cover.

2

AClock setting

1Press and set the time .

Press and hold for approximately 5 seconds to show time in 12-hour (am/pm) or 24 hour indication.

2Confirm .

Thank you for purchasing

Panasonic Air Conditioner.

Table of contents

Safety precautions……… 4-11

How to use……………………12-13

To learn more ………………… 14

Cleaning instructions……… 15

Troubleshooting………… 16-18

Information………………… 19

Accessories

Remote control

AAA or R03 batteries × 2

Remote control holder

Screws for remote control holder × 2

The illustrations in this manual are for explanation purposes only and may differ from the actual unit. They are subject

to change without notice for future improvement.

B Basic operation

1 Press MODE to select the desired mode.

AUTO HEAT COOL i AUTO-X FAN DRY

OFF/ON

2 Press to

start/stop the operation.

POWER

Please note that

the indication is on display to start the unit.

3Select the desired temperature.

Up

TEMP

Down

Selection range: 16.0 °C ~ 30.0 °C / 60 °F ~ 86 °F.

Press and hold for approximately 10 seconds to switch the temperature indication in °C or °F.

English

3

Panasonic CS-Z20VKR, CS-Z25VKR, CS-Z35VKR, CS-Z42VKR, CS-Z50VKR User Manual

Safety precautions

To prevent personal injury, injury to others or property damage, please comply with the following:

Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below:

This appliances is not intended for accessibility by the general public.

 

 

 

 

 

WARNING

This sign warns of death

 

 

 

 

 

 

 

 

 

 

or serious injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

This sign warns of injury

 

 

 

 

 

 

 

 

 

 

or damage to property.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The instructions to be followed are classified by the following symbols:

This symbol denotes an action that is PROHIBITED.

These symbols denote actions

COMPULSORY.

Power supply Indoor unit

Air inlet

Air outlet

Remote control

Air inlet

Outdoor unit Air outlet

4

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Please consult authorised dealer or specialist to clean the internal parts, repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.

Confirm with authorised dealer or specialist on usage of any specified refrigerant type. Using refrigerant type other than the specified may cause product damage, burst and injury etc.

Do not use means to accelerate the defrosting process or to clean, other than those recommended by manufacturer.

Any unfit method or using incompatible material may cause product damage, burst and serious injury.

Do not install the unit in a potentially explosive or flammable atmosphere.

Failure to do so could result in fire.

Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.

Do not touch the outdoor unit during lightning, it may cause electric shock.

Do not expose yourself directly to cold air for a long period to avoid excess cooling.

Do not sit or step on the unit, you may fall down accidentally.

Remote control

Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.

Power supply

Do not use a modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.

To prevent overheating, fire or electric shock:

Do not share the same power outlet with other equipment.

Do not operate with wet hands.

Do not over bend the power supply cord.

Do not operate or stop the unit by inserting or pulling out the power plug.

If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard.

It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fire.

To prevent overheating, fire or electric shock:

Insert the power plug properly.

Dust on the power plug should be periodically wiped with a dry cloth.

Stop using the product if any abnormality/ failure occurs and disconnect the power plug or turn off the power switch and breaker.

(Risk of smoke/fire/electric shock) Examples of abnormality/failure

The ELCB trips frequently.

Burning smell is observed.

Abnormal noise or vibration of the unit is observed.

Water leaks from the indoor unit.

Power cord or plug becomes abnormally hot.

Fan speed cannot be controlled.

The unit stops running immediately even if it is switched on for operation.

The fan does not stop even if the operation is stopped.

Contact your local dealer immediately for maintenance/repair.

This equipment must be earthed to prevent electrical shock or fire.

Prevent electric shock by switching off the power supply and unplug:

-Before cleaning or servicing,

-When extended non-use, or

-During abnormally strong lightning activity.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit.

Do not use for preservation of precise equipment, food, animals, plants, artwork or other objects. This may cause quality deterioration, etc.

Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation.

Do not expose plants or pet directly to airflow to avoid injury, etc.

Do not touch the sharp aluminium fin, sharp parts may cause injury.

Do not switch ON the indoor unit when waxing the floor. After waxing, aerate the room properly before operating the unit.

Do not install the unit in oily and smoky areas to prevent damage to the unit.

Do not dismantle the unit for cleaning purpose to avoid injury.

Do not step onto an unstable bench when cleaning the unit to avoid injury.

 

Do not place a vase or water container on the

 

 

unit. Water may enter the unit and degrade the

precautions

 

- Connected properly,

 

insulation. This may cause an electric shock.

 

 

Do not open window or door for long time during

 

 

operation, it may lead to inefficient power usage

 

 

and uncomfortable temperature changes.

 

 

Prevent water leakage by ensuring drainage pipe is:

 

 

- Kept clear of gutters and containers, or

Safety

 

- Not immersed in water

 

 

 

After a long period of use or use with any

 

 

combustible equipment, aerate the room regularly.

 

 

After a long period of use, make sure the

 

 

installation rack does not deteriorate to prevent

 

 

the unit from falling down.

English

Remote control

 

 

Do not use rechargeable (Ni-Cd) batteries. It

 

 

may damage the remote control.

 

To prevent malfunction or damage of the remote control:

Remove the batteries if the unit is not going to be used for a long period of time.

New batteries of the same type must be inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord to prevent electric shock.

nanoe-G generator

Do not touch the sharp pin which may cause

injury.

5

 

Safety precautions

WARNING

This appliance is filled with R32 (mild flammable refrigerant).

If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.

Indoor unit and outdoor unit

The appliance shall be installed, and/or operated in a room with floor area larger than Amin (m²) and keep away from ignition sources, such as heat/sparks/open flame or

hazardous areas such as gas appliances, gas cooking, reticulated gas supply systems or electric cooking appliances, etc.(Refer to Table A of Installation instructions table for Amin (m²))

Be aware that refrigerant may not contain an odour, highly recommended to ensure suitable flammable refrigerant gas detectors are present, operating and able to warn of a leak.

Keep any required ventilation openings clear of obstruction.

Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flame, sparks, or other sources of ignition. Else it may explode and cause injury or death.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as conventional refrigerant (R410A, R22) models.

Since the working pressure is higher than that of refrigerant R22 models, some of the piping and installation and service tools are special. Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model, always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side.

For R32 and R410A, the same flare nut on the outdoor unit side and pipe can be used.

The mixing of different refrigerants within a system is prohibited. Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent

erroneous charging with refrigerant R22 and for safety.

Therefore, check beforehand. [The charging port thread diameter for R32 and R410A is 1/2 inch.]

Must always ensure that foreign matter (oil, water, etc.) does not enter the piping. Also, when storing the piping, securely seal the opening by pinching, taping, etc. (Handling of R32 is similar to R410A.)

Operation, maintenance, repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by the manufacturer. Any

personnel conducting an operation, servicing or maintenance on a system or associated parts of the equipment should be trained and certified.

Any part of refrigerating circuit (evaporators, air coolers, AHU, condensers or liquid receivers) or piping should not be located in the proximity of heat sources, open flames, operating gas appliance or an operating electric heater.

The user/owner or their authorised representative shall regularly check the alarms, mechanical ventilation and detectors, at least once a year, where as required by national regulations, to ensure their correct functioning.

A logbook shall be maintained. The results of these checks shall be recorded in the logbook.

In case of ventilations in occupied spaces shall be checked to confirm no obstruction.

Before a new refrigerating system is put into service, the person responsible for placing the system in operation should ensure that trained and certified operating personnel are instructed on the basis of the instruction manual about the construction, supervision, operation and maintenance of

the refrigerating system, as well as the safety measures to be observed, and the properties and handling of the refrigerant used.

The general requirement of trained and certified personnel are indicated as below:

a)Knowledge of legislation, regulations and standards relating to flammable refrigerants; and,

b)Detailed knowledge of and skills in handling flammable refrigerants, personal protective equipment, refrigerant leakage prevention, handling of cylinders, charging, leak detection, recovery and disposal; and,

c)Able to understand and to apply in practice the requirements in the national legislation, regulations and Standards; and,

d)Continuously undergo regular and further training to maintain this expertise.

e)Air-conditioner piping in the occupied space shall be installed in such a way to protect against accidental damage in operation and service.

6