QUICK GUIDE GUÍA RÁPIDA
Operating Instructions
Air Conditioner
Model No.
Indoor Unit Single Split Outdoor Unit
CS-S9JKUW CU-S9JKU CS-S12JKUW CU-S12JKU CS-S18JKU CU-S18JKU CS-S22JKU CU-S22JKU
Multi Split
Outdoor Unit
CU-2S18JBU
ENGLISH |
2 ~ 9 |
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
ESPAÑOL |
10 ~ 17 |
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta.
Please register your product at : www.panasonic.com/register
For assistance, please call : (866)-292-7292
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2009. Unauthorized copying and distribution is a violation of law.
F567334
Thank you for purchasing
Panasonic Air Conditioner
TABLE OF CONTENTS
SAFETY PRECAUTIONS
2~3
MULTI AIR CONDITIONER
SYSTEM
4
INDOOR UNIT
5
REMOTE CONTROL
6~7
TROUBLESHOOTING
8
INFORMATION
9
QUICK GUIDE
BACK COVER
NOTE
The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.
OPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (˚F) |
Indoor |
|||
*DBT |
*WBT |
|||
|
|
|||
COOLING |
Max. |
89.6 |
73.4 |
|
Min. |
60.8 |
51.8 |
||
|
Temperature (˚F) |
Outdoor |
|||
*DBT |
*WBT |
|||
|
|
|||
COOLING |
Max. |
109.4 |
78.8 |
|
Min. |
60.8 |
51.8 |
||
|
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property damage, please comply with the following.
Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below:
WARNING This sign warns of death or serious injury.
This sign warns of injury or damage to CAUTION property.
The instructions to be followed are classified by the following symbols:
This symbol denotes an action that is
PROHIBITED.
These symbols denote an actions that is COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fire.
Do not install the unit in a potentially explosive or flammable atmosphere. Failure to do so could result in fire.
Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it may cause electric shock.
REMOTE CONTROL
Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries.
2
WARNING
POWER SUPPLY
Do not use modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.
Do not share the same power outlet with other equipment to prevent overheating and fire.
Do not operate with wet hands to prevent electric shock.
If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fire.
This equipment must be earthed to prevent electrical shock or fire.
In case of emergency or abnormal conditions (burnt smell, etc), turn off the power supply, and please consult authorized dealer.
Prevent electric shock by switching off the power supply when:
-Before cleaning or servicing.
-Extended non-use.
-Abnormally strong lightning activity.
|
Indoor |
|
|
Remote |
Unit |
Air Inlet |
|
|
|
||
Control |
|
|
|
|
|
Air Outlet |
Power |
|
|
|
Supply |
|
|
Outdoor |
Air Inlet |
|
|
Unit |
|
|
|
Air Inlet |
|
|
|
|
Air Outlet |
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, thinner or scouring powder.
Do not use for other purpose such as preservation of food.
Do not use any combustible equipment in front of the airflow outlet to avoid fire.
Do not expose yourself directly to cold air for a long period.
Do not sit or step on the unit, you may fall down accidentally.
Do not touch the sharp aluminium fin, sharp parts may cause injury.
Do not switch ON the indoor unit when waxing the floor. After waxing, aerate the room properly before operating the unit.
Do not install the unit in oily and smoky areas.
Ensure drainage pipe is connected properly.
Otherwise, leakage may occur.
Aerate the room regularly.
After long period of use, make sure the installation rack is not deteriorate to prevent the unit from falling down.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
Remove the batteries if the unit is not going to be used for a long period of time.
New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
ENGLISH
3
MULTI AIR CONDITIONER SYSTEM
Multi Split Outdoor Unit
(CU-2S18JBU)
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
INDOOR UNIT
•It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the first unit that turned on.
•During operation, heating and cooling mode could not be activated at the same time for different indoor unit. The power indicator blinks to indicate the indoor unit is standing by for different operation mode.
Living room
Multi Split Outdoor Unit
Bedroom
POWER SUPPLY
|
Models Number |
Time Delay Fuse |
Rated Volts |
|
|
CS-S9JKUW / CU-S9JKU |
15 Amps |
|
|
Single Split System |
CS-S12JKUW / CS-S9JKU |
15 Amps |
208/230V |
|
CS-S18JKU / CU-S18JKU |
20 Amps |
|||
|
|
|||
|
CS-S22JKU / CU-S22JKU |
25 Amps |
|
|
|
CS-S9JKUW, CS-S9JKUW / CU-2S18JBU |
|
|
|
Multi Split System |
CS-S9JKUW, CS-S12JKUW / CU-2S18JBU |
25 Amps |
208/230V |
|
|
CS-S12JKUW, CS-S12JKUW / CU-2S18JBU |
|
|
4
INDOOR UNIT
•Switch off the power supply before cleaning.
•Do not touch the aluminium fin, sharp parts may cause injury.
CAUTION
CLEANING INSTRUCTIONS
•Do not use benzene, thinner or scouring powder.
•Use only soap ( pH7) or neutral household detergent.
•Do not use water hotter than 104˚F.
2 |
4 |
HINT
•To ensure optimal performance of the unit, cleaning maintenance has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorized dealer.
1 |
7 |
ENGLISH
9 8
3 5
6
1INDOOR UNIT
•Wipe the unit gently with a soft, dry cloth.
2FRONT PANEL
Remove Front Panel
•Raise and pull to remove the front panel.
•Wash gently and dry.
Close Front Panel
•Press down both ends of the front panel to close it securely.
3REMOTE CONTROL RECEIVER
4ALUMINIUM FIN
5HORIZONTAL AIRFLOW DIRECTION LOUVER
S9JKUW, S12JKUW
• Manually adjustable.
S18JKU, S22JKU
• Do not adjust by hand.
6VERTICAL AIRFLOW DIRECTION LOUVER
•Do not adjust by hand.
7AUTO OFF/ON BUTTON
•Use when remote control is misplaced or a malfunction occurs.
Action |
Mode |
|
Press once. |
Auto |
|
Press and hold until 1 beep is heard, |
Cooling |
|
then release. |
||
|
||
Press the button to turn off. |
|
8 AIR PURIFYING FILTER
Vacuum the air purifying filter.
• It is recommended to clean the filter every 6 months.
• Replace the filter every 3 years or replace any damaged filter.
Part no.: CZ-SA20P
9 AIR FILTERS
• Air filter cleaning is required every two weeks.
• Wash/rinse the filters gently with water to avoid damage to the filter surface.
• Dry the filters thoroughly under the shade, away from fire or direct sunlight.
• Replace any damaged filters.
5
REMOTE CONTROL
Maximum distances: 33ft
INDICATOR
|
|
|
|
POWER |
(Green) |
|
|
|
|
TIMER |
(Orange) |
|
|
|
|
QUIET |
(Orange) |
|
|
|
|
POWERFUL |
(Orange) |
|
|
|
|
Press the remote control’s button
1 TO TURN ON OR OFF THE UNIT
•Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly.
2 TO SET TEMPERATURE
•Selection range: 60°F ~ 86°F.
•Operating the unit within the recommended temperature could induce energy saving.
COOL mode : 78˚F ~ 82˚F.
DRY mode : 2˚F ~ 4˚F lower than room temperature.
3 TO SELECT OPERATION MODE
AUTO mode - For your convenience
•During operation mode selection the power indicator blinks.
•Unit selects operation mode every 30 minutes according to temperature setting, outdoor and room temperature (For Single Split System).
•Unit selects operation mode every 3 hours according to temperature setting, outdoor and room temperature (For Multi Split System).
COOL mode - To enjoy cool air
•Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode.
DRY mode - To dehumidify the environment
•Unit operates at low fan speed to give a gentle cooling operation.
4 TO SELECT FAN SPEED (5 OPTIONS)
FAN SPEED
•For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
5TO ADJUST VERTICAL AIRFLOW DIRECTION (5 OPTIONS)
AIR SWING
•Keeps the room ventilated.
•In COOL/DRY mode, if AUTO is set, the louver swing up/down automatically.
6 TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)
(PAGE 7)
AIR SWING
•Keeps the room ventilated.
•In COOL/DRY mode, if AUTO is set, the louver swing left/right and up/down automatically.
Remote Control display
|
|
AUTO |
|
|
|
|
|
|
|
COOL |
|
|
FAN |
|
|
|
|
DRY |
|
|
|
||
|
|
|
|
SPEED |
|
||
|
|
|
|
|
|
AIR |
|
|
|
|
|
|
|
SWING |
|
|
|
|
|
OFF/ON |
|
1 |
|
|
|
MODE |
|
|
|
||