FAGOR FT0816BI, FT0814MI, FT0814DI, FT0814BI, FT0811MI Datasheet

...
0 (0)
On-State Current
8 Amp
FT08...I
HIGH COMMUTATION TRIAC
This series of TRIACs uses a high performance PNPN technology.
These devices are intended for AC control applications using surface mount technology.
The high commutation performances combined with high sensitivity, make them perfect in all applications like solid state relays, home appliances, power tools, small motor drives...
Jun - 02
Gate Trigger Current
< 25 mA to < 50 mA
Off-State Voltage
200 V ÷ 600 V
Repetitive Peak Off State
Voltage
PARAMETER VOLTAGE UnitSYMBOL
V
DRM
V
RRM
B
200 V
M
600
D
400
IPAK
(Plastic)
MT1
MT2
G
MT2
Absolute Maximum Ratings, according to IEC publication No. 134
RMS On-state Current
Non-repetitive On-State Current
Non-repetitive On-State Current
Fusing Current
Peak Gate Current
Peak Gate Dissipation
Gate Dissipation
Critical rate of rise of on-state current
Operating Temperature Range
Storage Temperature Range
Lead Temperature for soldering
I
T(RMS)
PARAMETER CONDITIONS Min. Max. UnitSYMBOL
I
TSM
I
TSM
I2t I
GM
P
GM
P
G(AV)
T
j
T
stg
T
L
All Conduction Angle, TC = 110 ºC
Half Cycle, 60 Hz
Half Cycle, 50 Hz
t
p
= 10 ms, Half Cycle
20 µs max.
20 µs max.
20 ms max.
10s max.
8
84
80
36
20
-40
-40
A
A
A
A
2
s
A
W
W
A/µs
ºC
ºC
ºC
4
10
1
+125
+150
260
di/dt
Tr 100 ns, F = 120 Hz
T
j
= 125 ºC
I
G
= 2 x I
GT
FT08...I
HIGH COMMUTATION TRIAC
Jun - 02
Electrical Characteristics
Gate Trigger Current
Off-State Leakage Current
On-state Voltage
Gate Trigger Voltage
Gate Non Trigger Voltage
Holding Current
Latching Current
Critical Rate of Voltage Rise
PARAMETER CONDITIONS SENSITIVITY
Unit
SYMBOL
I
GT
I
DRM
VD = 12 V
DC
, R
L
= 33
mA
1
5
1.55
1.3
0.2
1.6
100
mA
µA
V
V
V
mA
mA
V/µs
A/ms
MAX
MAX
MAX
MAX
MAX
MIN
MAX
MAX
MAX
MIN
MIN
MIN
MIN
/I
RRM
V
TM
*
V
GT
V
GD
IH* I
L
dv / dt*
R
th(j-a)
Thermal Resistance Junction-Ambient
Tj = 25 ºC
V
R
= V
DRM
,
IT = 11 Amp, tp = 380 µs, Tj = 25 ºC
VD = 12 V
DC
, R
L
= 33, T
j
= 25 ºC
I
T
= 100 mA , Gate open, Tj = 25 ºC
I
G
= 1.2 IGT,
Tj
= 25 ºC
V
D
= 0.67 x V
DRM
, Gate open
T
j
= 125 ºC
Quadrant
Q1÷Q3
Q1÷Q3
Q1÷Q3
Q1,Q3
Q2
V
D
= V
DRM
, R
L
= 3.3K, T
j
= 125 ºC
ºC/W
ºC/W
16
50
50
80
80
1000
(*) For either polarity of electrode MT2 voltage with reference to electrode MT1.
R
th(j-c)
Thermal Resistance Junction-Case
(di/dt)c*
Critical Rate of Current Rise
(dv/dt)c= 0.1 V/µs T
j
= 125 ºC
(dv/dt)c= 15 V/µs T
j
= 125 ºC
without snubber Tj = 125 ºC
Tj = 125 ºC
PART NUMBER INFORMATION
FAGOR
TRIAC
CURRENT
CASE
VOLTAGE
SENSITIVITY
F T 08 11 B I 00
FORMING
TU
PACKAGING
14
35
35
50
60
400
11
25
25
25
50
200
T
j
= 25 ºC
V
R
= V
RRM
,
9
4.5
9
4.5
4.5
Loading...
+ 2 hidden pages