DVM9912 – AUTORANGING MULTIMETER

1. Introduction

To all residents of the European Union

Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment.

Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for recycling.

This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities.

Thank you for buying the DVM9912! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer.

2. Safety information

The following safety information must be observed in order to ensure maximum personal safety during the use of this device.

Do not use the meter if the meter or the test leads look damaged or if you suspect the meter is not operating properly.

Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats or any other approved insulating material.

Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Even small amounts of current can be dangerous.

Use caution when working above 60VDC or 30VAC rms as such voltages pose a shock hazard.

When using the probes, keep your fingers behind the finger guards on the probes.

Measuring voltage which exceeds the limits of the multimeter may damage the meter and expose the operator to electrical shocks. Always respect the meter voltage limits as stated on the front of the meter.

Never apply voltage or current to the meter that exceeds the specified maximum:

Input Limits

Function

Max. Output

VDC or VAC

600VDC, 600VAC

mA DC/AC

400mA DC/AC

A DC/AC

10A DC/AC (30 seconds max every 15 minutes)

Frequency, Resistance, Capacitance, Duty Cycle,

250V DC/AC

Diode test, Continuity

 

Temperature

250V DC/AC

DVM9912

3

VELLEMAN

3. Safety symbols

 

 

 

This symbol next to another symbol, terminal or operating device indicates that

 

 

 

the operator should pay heed to the instructions in the manual in order to avoid

 

 

 

personal injury or damage to the meter.

 

 

 

This warning symbol indicates a potentially hazardous situation, which, if not

 

WARNING

 

 

 

avoided, could result in serious injury or death.

 

 

 

 

 

 

 

This warning symbol indicates a potentially hazardous situation, which, if not

 

CAUTION

 

 

 

avoided, could result in damage to the product.

 

 

 

A terminal marked with this symbol should not be connected to a circuit point of

 

 

 

which the voltage exceeds 500 VAC or VDC above ground.

 

 

 

This symbol next to one or more terminals indicated that they may carry

 

 

 

particularly hazardous voltages. For maximum safety, do not use the meter and

 

 

 

the test leads if you see this symbol.

4.Controls and jacks

1.4000 count LCD-Display with symbols

2.function switch

3.10A (positive) input jack for 10A DC or AC measurements

4.COM (negative) input jack

5.positive input jack

6.MODE push button

7.RANGE push button

8.DATA HOLD push button

9.RELATIVE push button

5.Symbols and indicators

 

Continuity

BAT

Low Battery

 

Diode

DATA HOLD

Data Hold

AUTO

Auto ranging

AC

Alternating Current or Voltage

DC

Direct Current or Voltage

6. Operation

WARNING: Risk of electrocution. High voltage circuits, both AC and DC, are very dangerous and should be measured with great care.

1.ALWAYS turn the function switch to the OFF position when the meter is not in use. This meter has an auto OFF function that automatically switches the meter OFF after 15 minutes of inactivity.

2.If “OL” appears on the display during a measurement, the value exceeds the range you have selected. Change to a higher range.

DVM9912

4

VELLEMAN

NOTE: In some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This is normal and is caused by the high input sensitivity. The reading will stabilise and give a proper measurement when connected to a circuit.

MODE BUTTON

To select Diode/Continuity, DC/AC, Hz/%Duty

RANGE BUTTON

When the meter is turned on for the first time, it automatically goes into Autoranging mode. This mode automatically selects the best range for the measurements and is generally the best mode for most measurements. For measurements situations that require a manually selected range, perform the following actions:

1.Press the RANGE button. The “AUTO” indication on the display will disappear.

2.Press the RANGE button to go through the available ranges and you select the range you want.

3.Press and hold the RANGE button for 2 seconds to exit the ManualRanging mode and return to AutoRanging.

DATA HOLD BUTTON

The data hold function allows the meter to “freeze” a measurement for later reference.

1.Press the DATA HOLD button to freeze the reading on the display. The indicator “HOLD” will appear on the display.

2.Press DATA HOLD again to return to normal operation.

RELATIVE BUTTON

The relative measurement feature allows you to make measurements relative to a stored reference value. A reference voltage, current, etc. can be stored and measurements made in comparison to that value. The displayed value is the difference between the reference value and the measured value.

1.Perform any measurement as described in the operating instructions.

2.Press the RELATIVE button to store the reading in the display and the “REL” indicator will appear on the display.

3.The display will now indicate the difference between the stored value and the measured value.

4.Press the RELATIVE button to return to normal operation.

7. Measurements

DC VOLTAGE MEASUREMENTS

CAUTION: Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.

DVM9912

5

VELLEMAN

1.Set the function switch to the V position (“mV” will appear on the display). The device will automatically select DC.

2.Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (V) jack.

3.Touch the test probe tips to the circuit under test. Be sure to observe the correct polarity (red lead to positive, black lead to negative).

4.Read the voltage on the display. The display will indicate the proper decimal point and value. If the polarity is reversed, the display will show (-) minus before the value.

AC VOLTAGE MEASUREMENTS

WARNING: Risk of electrocution. The probe tips may not be long enough to contact the live parts inside some 240V appliance outlets because the contacts are recessed deep in the outlets. As a result, the reading may show 0V when the outlet actually carries voltage. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that there is no voltage is present.

CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.

1.Set the function switch to the V position. Press MODE to select AC voltage.

2.Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (V) jack.

3.Touch the test probe tips to the circuit under test.

4.Read the voltage in the display. The display will indicate the proper decimal point, value and symbol (AC, V, etc.).

DC CURRENT MEASUREMENTS

CAUTION: Do not carry out current measurements on the 10A scale for a period longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.

1.Insert the black test lead banana plug into the negative (COM) jack.

2.For current measurements up to 4000µ A DC, set the function switch to the µ A position and insert the red test lead banana plug into the (µ A) jack.

3.For current measurements up to 400mA DC, set the function switch to the mA range and insert the red test lead banana plug into the (mA) jack.

4.For current measurements up to 10A DC, set the function switch to the A position and insert the red test lead banana plug into the 10A jack.

5.Press the MODE button until “DC” appears in the display.

6.Remove the power from the circuit under test, then open up the circuit at the point where you wish to measure current.

7.Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit.

8.Apply power to the circuit.

9.Read the current on the display. The display will indicate the proper decimal point, value and symbol.

DVM9912

6

VELLEMAN

AC CURRENT MEASUREMENTS

WARNING: To avoid electric shock, do not measure AC current on any circuit with a voltage exceeding 250V AC.

CAUTION: Do not carry out current measurements on the 10A scale for a period longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads.

1.Insert the black test lead banana plug into the negative (COM) jack.

2.For current measurements up to 4000µ A AC, set the function switch to the µ A position and insert the red test lead banana plug into the (µ A) jack.

3.For current measurements up to 400mA AC, set the function switch to the mA range and insert the red test lead banana plug into the (mA) jack.

4.For current measurements up to 10A AC, set the function switch to the A position and insert the red test lead banana plug into the 10A jack.

5.Press the MODE button until “AC” appears in the display.

6.Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.

7.Touch the black test probe tip to the negative side of the circuit. And touch the red test probe tip to the positive side of the circuit.

8.Apply power to the circuit.

9.Read the current on the display. The display will indicate the proper decimal point, value and symbol.

RESISTANCE MEASUREMENTS

WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.

1.Set the function switch to the position.

2.Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive jack.

3.Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.

4.Read the resistance on the display. The display will indicate the proper decimal point, value and symbol.

CONTINUITY CHECK

WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.

1.Set the function switch to the position.

2.Insert the black lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack ( ).

3.Press the MODE button until the symbol appears on the display.

4.Touch the test probe tips to the circuit or wire you wish to check.

If the resistance is less than approximately 30 , the audible signal will sound. The display will also show

the actual resistance.

DVM9912

7

VELLEMAN

DIODE CHECK

WARNING: To avoid electric shock, do not test any diode that has voltage on it.

1.Set the function switch to the position.

2.The symbol will appear on the screen.

3.Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack ( ).

4.Touch the test probe tips to the diode or semiconductor junction you wish to test. Write down the meter reading.

5.Reverse the probe polarity by switching probe position. Write down this reading.

6.The diode or junction can be evaluated as follows:

A.If one reading shows a value and the other reading shows OL, the diode is good.

B.If both readings show OL, the device is open.

C.If both readings are very low or 0, the device is shorted.

NOTE: The value indicated on the display during the diode check is the forward voltage.

FREQUENCY MEASUREMENT

1.Set the function switch to the Hz% position.

2.Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (F).

3.Touch the test probe tips to the circuit under test.

4.Read the frequency on the display. The digital reading will indicate the proper decimal point, symbols (Hz, kHz) and value.

CAPACITANCE MEASUREMENTS

WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords.

1.Set the function switch to the CAP position (“nF” and a low value will appear in the display).

2.Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead banana plug into the positive (+) jack (CAP).

Touch the test leads to the capacitor to be tested. The display will indicate the proper decimal point, value and symbol.

TEMPERATURE MEASUREMENTS

WARNING: To avoid electric shock, disconnect both test probes from any source of voltage before carrying out a temperature measurement.

1.If you wish to measure temperature in oF, set the function switch to the oF range. If you wish to measure temperature in oC, set the function switch to the oC range.

2.Insert the type K thermocouple probe black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive TEMP jack.

3.Touch the temperature probe head to the part of which you wish to measure the temperature. Keep touching the part under test until the reading stabilises (about 30 seconds).

Read the temperature on the display. The digital reading will indicate the proper decimal point and value.

DVM9912

8

VELLEMAN

BATTERY REPLACEMENT

WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery door.

1.When the batteries are exhausted or drop below the operating voltage, “BAT” will appear in the right-hand side of the LCD display. The battery should be replaced.

2.Follow instructions for installing a battery. See the battery installation section of this manual.

3.Dispose of the old battery properly.

WARNING: To avoid electric shock, do not operate your meter until the battery door is in place and fastened securely.

BATTERY INSTALLATION

WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery door.

1.Disconnect the test leads from the meter.

2.Open the battery door by loosening the screw using a Phillips head screwdriver.

3.Insert the battery into battery holder, observing the correct polarity.

4.Put the battery door back in place. Secure with the two screws.

WARNING: To avoid electric shock, do not operate your meter until the battery door is in place and fastened securely.

NOTE: If your meter does not work properly, check the fuses and battery to make sure that they are still in good operating condition and that they are properly inserted.

REPLACING THE FUSES

WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the fuse door.

1.Disconnect the test leads from the meter and any item under test.

2.Open the fuse door by loosening the screw on the door using a Phillips head screwdriver.

3.Remove the old fuse from its holder by gently pulling it out.

4.Install the new fuse into the holder.

5.Always use a fuse of the proper size and value (0.5A/250V fast blow for the 400mA range, 10A/250V fast blow for the 10A range).

Put the fuse door back in place. Insert the screw and tighten it securely.

WARNING: To avoid electric shock, do not operate your meter until the fuse door is in place and fastened securely.

DVM9912

9

VELLEMAN

8. Specifications

Compliance

 

EN61010-1

Insulation

 

class 2, double insulation

Overvoltage capacity

 

CATIII 600V

Display

 

4000 counts LCD with function indication

Polarity

 

automatic, (-) negative polarity indication

Overrange

 

"OL" mark indication

Low Battery indication

 

"BAT" is displayed when the battery voltage drops below the

 

 

 

 

operating level

Measurement rate

 

2 times per second, nominal

Auto power off

 

meter automatically shuts down after approx. 15 minutes of

 

 

 

 

inactivity

Operating environment

 

0°C to 50°C (32°F to 122°F) at < 70% relative humidity

Storage temperature

 

-20°C to 60°C (-4°F to 140°F) at < 80% relative humidity

Use

 

inside use, max. height 2000m

Pollution degree

 

2

 

 

 

 

Power

 

1 x 9V battery, NEDA 1604, IEC 6F22

Dimensions

 

150 (H) x 70 (W) x 48 (D) mm

Weight

 

approx. 255g

Accuracy is given at 18°C to 28°C (65°F to 83°F), less than 70% RH

DC Voltage (Autoranging)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

 

Resolution

 

 

Accuracy

 

 

400.0mV

 

 

0.1mV

 

 

+0.5% of rdg + 2 dgts

 

 

4.000V

 

 

1mV

 

 

+1.2% of rdg + 2 dgts

 

 

40.00V

 

 

10mV

 

 

 

 

400.0V

 

 

100mV

 

 

 

 

 

600V

 

 

1V

 

 

+1.5% of rdg + 2 dgts

 

 

Input Impedance: 7.8M

 

 

 

 

 

Maximum Input: 600VDC or 600VAC rms.

 

 

 

 

 

AC Voltage (Autoranging except 400mV)

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

400.0mV

 

0.1mV

 

+1.5%of rdg + 15 dgts

 

4.000V

 

1mV

 

+1.2% of rdg + 3 dgts

 

40.00V

 

10mV

 

+1.5% of rdg + 3 dgts

 

400.0V

 

100mV

 

 

 

 

 

600V

 

1V

 

+2.0% of rdg + 4 dgts

 

Input Impedance: 7.8M

Frequency Range: 50 to 400Hz

Maximum Input: 600V DC or 600V ac rms.

DVM9912

10

VELLEMAN

DC Current (Autorranging for uA and mA)

Range

Resolution

Accuracy

400.0uA

0.1uA

+1.0% of rdg + 3 dgts

4000uA

1uA

+1.5% of rdg + 3 dgts

40.00mA

10uA

400.0mA

100uA

 

10A

10mA

+2.5% of rdg + 5 dgts

Overload Protection: 0.5A / 250V and 10A / 250V fuse.

Maximum Input: 400mA DC or 400mA AC rms on uA / mA ranges, 10A DC or AC rms on 10A range.

AC Current (Autoranging for uA and mA)

Range

Resolution

Accuracy

400.0uA

0.1uA

+1.5% of rdg + 5 dgts

4000uA

1uA

+1.8% of rdg + 5 dgts

40.00mA

10uA

400.0mA

100uA

 

10A

10mA

+3.0% of rdg + 7 dgts

Overload Protection: 0.5A / 250V and 10A / 250V Fuse. Frequency Range: 50 to 400 Hz

Maximum Input: 400mA DC or 400mA AC rms on uA / mA ranges, 10A DC or AC rms on 10A range.

Resistance (Autoranging)

Range

Resolution

Accuracy

400.0

0.1

+1.2% of rdg + 4 dgts

4.000k

1

+1.0% of rdg + 2 dgts

40.00k

10

 

 

400.0k

100

+1.2% of rdg + 2 dgts

4.000M

1k

 

 

40.00M

10k

+2.0% of rdg + 3 dgts

Input Protection: 250VDC or 250VAC rms.

 

 

Capacitance (Autoranging)

 

 

 

 

 

 

Range

Resolution

Accuracy

 

4.000nF

1pF

+5.0% of rdg+50 dgts

 

40.00nF

10pF

+5.0% of rdg + 7 dgts

 

400.0nF

0.1nF

+3.0% of rdg + 5 dgts

 

4.000uF

1nF

 

40.00uF

10nF

 

 

200.0uF

0.1uF

+5.0% of rdg + 5 dgts

 

Input Protection: 250VDC or 250VAC rms.

DVM9912

11

VELLEMAN

Frequency (Autoranging)

Range

Resolution

Accuracy

 

9.999Hz

0.001Hz

 

 

 

 

 

99.99Hz

0.01Hz

+1.5% of rdg + 5 dgts

 

999.9Hz

0.1Hz

 

 

 

 

 

9.999kHz

1Hz

+1.2% of rdg + 3 dgts

 

99.99kHz

10Hz

 

999.9kHz

100Hz

 

 

 

 

 

9.999MHz

1kHz

+1.5% of rdg + 4 dgts

 

Sensitivity: >0.5V RMS while ≤1MHz;

 

 

 

 

 

Sensitivity: >3V RMS while >1MHz;

 

 

 

 

 

Overload protection: 250VDC or AC rms.

 

 

 

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

Resolution

 

Accuracy

 

0.1%~99.9%

0.1%

 

 

+1.2% of rdg + 2 dgts

 

Pulse width: >100us, <100ms;

 

 

 

 

 

Frequency width: 5Hz – 150kHz

 

 

 

 

 

Sensitivity: >0.5V RMS

 

 

 

 

 

 

 

Overload protection: 250V DC or AC rms.

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

 

 

Accuracy

 

-20oC~+760oC

 

1 oC

 

 

 

+3% of rdg

 

 

 

 

 

 

 

 

-4 oF~+1400 oF

 

1oF

 

 

 

+5 oC/9 oF

 

Sensor: Type K Thermocouple

 

 

 

 

 

Overload protection: 250VDC or AC rms.

 

 

 

 

 

Diode Test

 

 

 

 

 

 

 

 

 

 

 

 

 

Test current

Resolution

 

 

Accuracy

 

0.3mA typical

1 mV

 

 

+10% of rdg + 5 dgts

 

Open circuit voltage: 1.5V DC typical

Overload protection: 250V DC or AC rms.

Audible Continuity

Audible threshold: Less than 150

Test current: <0.3mA

Overload protection: 250V DC or AC rms.

For more info concerning this product, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.

DVM9912

12

VELLEMAN

DVM9912 –MULTIMETER MET AUTOMATISCHE BEREIKINSTELLING

1. Inleiding

Aan alle ingezetenen van de Europese Unie Belangrijke milieu-informatie betreffende dit product

Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt weggeworpen, dit toestel schade kan toebrengen aan het milieu.

Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een gespecialiseerd bedrijf terechtkomen voor recyclage.

U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen. Respecteer de plaatselijke milieuwetgeving.

Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.

Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel in gebruik neemt. Werd het toestel beschadigd tijdens het transport, installeer het dan niet en raadpleeg uw dealer.

2. Informatie omtrent de veiligheid

Respecteer volgende punten om de maximale veiligheid gedurende het gebruik te garanderen.

Gebruik de meter niet wanneer de meter of de meetsnoeren sporen van beschadiging vertonen of de meter niet naar behoren functioneert.

Isoleer uzelf tijdens metingen. Raak nooit metalen buizen, toestellen enz. aan die potentieel gevaarlijk kunnen zijn. Draag droge kledij en rubberen schoenen of sta op een rubberen mat.

Ontkoppel het te testen toestel van het lichtnet alvorens het circuit te onderbreken. Zelfs een kleine stroomstoot kan gevaarlijk zijn.

Wees voorzichtig wanneer u spanningen van 60VDC / 30VAC rms of meer werkt om elektroshocks te vermijden.

Houd uw vingers achter de bescherming wanneer u de meetsnoeren gebruikt.

Het meten van spanningen hoger dan de toegestane maxima kunnen de multimeter beschadigen en de gebruiker aan elektroshocks blootstellen. Houd u aan de toegestane maximale waarden.

Meet geen spanningen of stroom hoger dan de vermelde maxima:

Ingang

Functie

Max. uitgang

VDC of VAC

600VDC, 600VAC

mA DC/AC

400mA DC/AC

A DC/AC

10A DC/AC (max. 30 seconden elke 15 minuten)

Frequentie, weerstand, capaciteit, duty cycle,

250V DC/AC

diodetest, continuïteit

 

Temperatuur

250V DC/AC

DVM9912

13

VELLEMAN

3. Veiligheidssymbolen

 

 

 

Dit symbool naast een ander symbool, terminal of toestel geeft aan dat de

 

 

 

gebruiker aandacht moet schenken aan de instructies in de handleiding om

 

 

 

kwetsuren en beschadiging aan de meter te vermijden.

 

 

 

Geeft een gevaarlijke situatie weer en kan tot kwetsuren leiden of de dood tot

 

WARNING

 

 

 

gevolg hebben.

 

 

 

 

 

 

 

Geeft een gevaarlijke situatie weer en kan tot beschadiging van de meter leiden.

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

Vermijd aansluitingen aan een circuit met een spanning hoger dan 500 VAC of

 

 

 

VDC.

 

 

 

Gevaarlijke spanning. Vermijd gebruik van de meter en meetsnoeren voor uw

 

 

 

eigen veiligheid.

4.Omschrijving

1.LCD (4000 punten) met symbolen

2.Draaischakelaar

3.10A (positief) ingang voor 10A DC of AC metingen

4.COM (negatief) ingang

5.positieve ingang

6.MODE drukknop

7.RANGE drukknop

8.DATA HOLD drukknop

9.RELATIVE drukknop

5.Symbolen en aanduidingen

 

Continuïteit

BAT

Zwakke batterij

 

Diode

DATA HOLD

Data Hold

AUTO

Automatische bereikinstelling

AC

Wisselstroom of –spanning

DC

Gelijkstroom of –spanning

6. Gebruik

WAARSCHUWING: Elektroshocks. Hoge spanningen, zowel AC als DC, zijn zeer gevaarlijk. Wees voorzichtig tijdens metingen.

1.Plaats de draaischakelaar ALTIJD op OFF wanneer het toestel niet wordt gebruikt. Deze meter is uitgerust met een automatische uitschakeling na 15 minuten.

2.Wanneer “OL” tijdens een meting op de display verschijnt, dan overschrijdt u het gekozen bereik. Kies een hoger bereik.

DVM9912

14

VELLEMAN

OPMERKING: Het is mogelijk dat, wanneer de meetsnoeren niet in de meter zitten, het LCD-scherm een willekeurige en wisselende waarde weergeeft, meestal in de lage wisselspanningsen gelijkspanningsbereiken. Dit is normaal en is te wijten aan de gevoeligheid. De waarde stabiliseert zich en wordt nauwkeurig wanneer u de meetsnoeren aan een circuit sluit.

MODE

Selecteren van diode/continuïteit, DC/AC, Hz/%Duty

RANGE

Wanneer u de meter voor het eerst inschakelt, dan stelt hij zich automatisch in de autoranging mode. Deze modus selecteert automatisch het meest geschikte bereik voor uw meting en is doorgaans de beste meetinstelling. Ga als volgt te werk wanneer u manueel het bereik wenst in te stellen:

1.Druk op RANGE. “AUTO” verdwijnt van de LCD.

2.Druk op RANGE om de beschikbare bereiken weer te geven en selecteer het gewenste bereik.

3.Houd RANGE gedurende 2 seconden ingedrukt om de manuele instellingsmodus te verlaten en om naar de autoranging terug te keren.

DATA HOLD

Met deze functie kunt u de weergegeven waarde op het scherm vastzetten en als referentie gebruiken.

1.Druk op DATA HOLD om de waarde vast te zetten. “HOLD” verschijnt op het scherm.

2.Druk opnieuw op DATA HOLD om naar de normale gebruikersmodus terug te keren.

RELATIVE

Met deze kunt u metingen verrichten en deze vergelijken met een opgeslagen waarde. U kunt een referentiewaarde, bvb. een spanning, stroom enz. opslaan en metingen verrichten. De weergegeven waarde is het verschil tussen de referentie en de meting.

1.Verricht een meting zoals beschreven in deze handleiding.

2.Druk op RELATIVE om deze waarde op te slaan. “REL” verschijnt op de LCD.

3.De LCD geeft nu het verschil tussen de opgeslagen referentiewaarde en de gemeten waarde.

4.Druk op RELATIVE om naar de normale gebruikersmodus terug te keren.

7. Metingen

METEN VAN GELIJKSPANNINGEN

OPGELET: Verricht geen gelijkspanningsmetingen terwijl u de motor van een circuit inof uitschakelt. Hoge spanningspieken kunnen de meter beschadigen.

DVM9912

15

VELLEMAN

1.Plaats de draaischakelaar op V (“mV” verschijnt op de LCD). De meter kiest automatisch DC.

2.Koppel het zwarte meetsnoer met de negatieve (COM) bus en het rode meetsnoer met de positieve (V) bus.

3.Raak het te testen circuit met de sondes. Respecteer de polariteit (rode meetsnoer naar positief, zwarte meetsnoer naar negatief).

4.Lees de weergegeven waarde. De LCD geeft het decimale punt en de waarde weer. Werd de polariteit omgekeerd, dan verschijnt (-) op de LCD.

METEN VAN WISSELSPANNINGEN

WAARSCHUWING: Gevaar voor elektroshocks. Het is mogelijk dat de sondes te kort zijn en u de te meten contactpunten in enkele 240V-toestellen niet kunt bereiken. De waarde op de LCD is dan 0V, ook al staat het toestel onder spanning. Zorg ervoor dat de sondes het circuit raken alvorens te concluderen dat het toestel niet onder spanning staat.

OPGELET: Verricht geen gelijkspanningsmetingen terwijl u de motor van een circuit inof uitschakelt. Hoge spanningspieken kunnen de meter beschadigen.

1.Plaats de draaischakelaar op V. Druk op MODE om AC te selecteren.

2.Koppel het zwarte meetsnoer met de negatieve (COM) bus en het rode meetsnoer met de positieve (V) bus.

3.Raak het te testen circuit met de sondes.

4.Lees de weergegeven waarde. De LCD geeft het decimale punt, de waarde en het symbool (AC, V enz.) weer.

METEN VAN GELIJKSTROOM

OPGELET: Verricht geen metingen gedurende langer dan 30 seconden met een bereik van 10A om beschadiging aan de meter en/of meetsnoeren te vermijden.

1.Koppel het zwarte meetsnoer met de negatieve (COM) bus.

2.Voor gelijkstroommetingen tot 4000µ A, plaats de draaischakelaar op µ A en koppel het rode meetsnoer met de (µ A) bus.

3.Voor gelijkstroommetingen tot 400mA, plaats de draaischakelaar op mA en koppel het rode meetsnoer met de (mA) bus.

4.Voor gelijkstroommetingen tot 10A, plaats de draaischakelaar op A en Koppel het rode meetsnoer met de 10A-bus.

5.Druk op MODE tot “DC” op de LCD verschijnt.

6.Schakel de voeding van het te testen circuit uit. Onderbreek het circuit en verricht de meting.

7.Raak de negatieve zijde van het circuit met het zwarte meetsnoer. Raak de positieve zijde met het rode meetsnoer.

8.Schakel de voeding in.

9.Lees de weergegeven waarde. De LCD geeft het decimale punt, de waarde en het symbool weer.

DVM9912

16

VELLEMAN

Loading...
+ 37 hidden pages