Graco Husky 307 User Manual

5 (1)
Graco Husky 307 User Manual

Husky 307 Plastic Pumps

Air-Operated Double Diaphragm

Technical Specifications

Husky 307 Plastic Pumps

Acetal

Polypropylene

Maximum fluid working pressure

100 psi (7 bar, 0.7 MPa)

100 psi (7 bar, 0.7 MPa)

Maximum free flow delivery*

7.0 gpm (26.5 lpm)

7.0 gpm (26.5 lpm)

Maximum pump speed

330 cpm

330 cpm

Displacement per cycle**

0.02 gallon (0.076 liter)

0.02 gallon (0.076 liter)

Maximum suction lift (D31255)

12 ft (3.7 m) dry

12 ft (3.7 m) dry

Maximum size pumpable solids

0.06 in (1.5 mm)

0.06 in (1.5 mm)

Maximum ambient operating temperature***

180°F (65.5°C)

150°F (65.5°C)

Maximum diaphragm operating temperature***

Refer to page 5

Refer to page 5

Typical sound level at 50 psi

75 dBa

75 dBa

(3.5 bar, 0.35 MPa) air @ 50 cpm

 

 

Maximum air consumption

6 scfm (0.17 m3/min)

6 scfm (0.17 m3/min)

Air pressure operating range

20 to 100 psi

20 to 100 psi

 

(1.4 to 8.4 bar, 0.14 to 0.84 MPa)

(1.4 to 8.4 bar, 0.14 to 0.84 MPa)

Air inlet size

1/4 npt(f) or bspt(f)

1/4 npt(f) or bspt(f)

Fluid inlet & outlet size****

3/8 npt(f)

3/8 npt(f)

Weight

5.2 lb (2.4 kg)

4.75 lb (2.2 kg)

Wetted parts (in addition to ball, seat and

Acetal with Stainless

Polypropylene, PTFE

diaphragm materials–which may vary by pump)

Steel fibers, PTFE

 

Instruction manual

308553

308553

*Flow rates are with muffler and do not vary based on diaphragm material

**Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type

***Actual pump performance may be affected by prolonged usage at temperature

Performance Chart

FLUID OUTLET PRESSURE psi (bar, MPa)

120

(8.4, 0.84)

100

(7, 0.7)

80

(5.5, 0.55)

60

(4.1, 0.41)

40

(2.8, 0.28)

20

(1.4, 0.14)

0 gpm 0 (lpm)

Husky 307 Performance

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

(0.17)

 

 

 

 

 

 

A

 

 

 

 

 

5

 

A

 

 

 

 

 

 

 

 

(0.14)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

(0.11)

 

B

 

 

C

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0.085)

 

 

 

 

 

 

 

 

 

 

 

 

2

 

C

 

D

 

 

 

 

 

 

 

(0.057)

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

(0.028)

 

 

 

 

D

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

2

3

4

5

6

7

 

 

8

(3.8)

(7.6)

(11.4)

(15.2)

(19.0)

(22.7)

(26.5)

 

(30.0)

 

 

 

 

FLUID FLOW

 

 

 

 

 

 

 

 

 

 

(Pump tested in water with inlet submerged

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR PRESSURE

 

 

LEGEND

 

 

 

 

 

 

 

A

= at 100 psi (7 bar, 0.7 MPa)

 

Air Consumption

 

 

 

 

 

 

B

= at 70 psi (4.8 bar, 0.48 MPa)

Fluid Pressure

 

 

 

 

 

 

 

 

 

 

 

C= at 40 psi (2.8 bar, 0.28 MPa)

D= at 20 psi (1.4 bar, 0.14 MPa)

AIR CONSUMPTION scfm (m3/min

updated 2/15

PROCESS EQUIPMENT CATALOG

 

 

Loading...