IDT29FCT520AT/BT/CT/DT, 521AT/BT/CT/DT
MULTILEVEL PIPELINE REGISTERS MILITARY AND COMMERCIAL TEMPERATURE RANGES
6.2 3
CAPACITANCE (TA = +25°C, f = 1.0MHz)ABSOLUTE MAXIMUM RATINGS
(1)
Symbol Rating Commercial Military Unit
VTERM
(2)
Terminal Voltage
with Respect to
GND
–0.5 to +7.0 –0.5 to +7.0 V
VTERM
(3)
Terminal Voltage
with Respect to
GND
–0.5 to
V
CC +0.5
–0.5 to
VCC +0.5
V
TA Operating
Temperature
0 to +70 –55 to +125 °C
TBIAS Temperature
Under Bias
–55 to +125 –65 to +135 °C
TSTG Storage
Temperature
–55 to +125 –65 to +150 °C
PT Power Dissipation 0.5 0.5 W
IOUT DC Output
Current
–60 to +120 –60 to +120 mA
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RAT-
INGS may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is
not
implied. Exposure to absolute maximum rating conditions for
extended periods may affect reliability. No terminal voltage may exceed
V
CC by +0.5V unless otherwise noted.
2. Input and V
CC terminals only.
3. Outputs and I/O terminals only.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: TA = 0°C to +70°C, VCC = 5.0V ± 5%; Military: TA = –55°C to +125°C, VCC = 5.0V ± 10%
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
V
IH Input HIGH Level Guaranteed Logic HIGH Level 2.0 — — V
V
IL Input LOW Level Guaranteed Logic LOW Level — — 0.8 V
I
IH Input HIGH Current
(4)
VCC = Max. VI = 2.7V — — ±1 µA
I
IL Input LOW Current
(4)
VCC = Max. VI = 0.5V — — ±1 µA
I
OZH High Impedance
(4)
VCC = Max. VO = 2.7V — — ±1 µA
I
OZL Output Current VO = 0.5V — — ±1
I
I Input HIGH Current
(4)
VCC = Max., VI = VCC (Max.) — — ±1 µA
V
IK Clamp Diode Voltage VCC = Min., IN = –18mA — –0.7 –1.2 V
I
OS Short Circuit Current VCC = Max.
(3)
, VO = GND –60 –120 –225 mA
V
OH Output HIGH Voltage VCC = Min. IOH = –6mA MIL. 2.4 3.3 — V
V
IN = VIH or VIL IOH = –8mA COM’L.
I
OH = –12mA MIL. 2.0 3.0 —
I
OH = –15mA COM’L.
V
OL Output LOW Voltage VCC = Min. IOL = 32mA MIL. — 0.3 0.5 V
V
IN = VIH or VIL IOL = 48mA COM’L.
V
H Input Hysteresis — — 200 — mV
I
CC Quiescent Power VCC = Max. — 0.01 1 mA
Supply Current V
IN = GND or VCC
NOTES: 2619 tbl 05
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at V
CC = 5.0V, +25°C ambient.
3. Not more than one output should be shorted at one time. Duration of the short circuit test should not exceed one second.
4. The test limit for this parameter is ±5µA at T
A = -55°C.
Symbol Parameter
(1)
Conditions Typ. Max. Unit
CIN Input
Capacitance
VIN = 0V 6 10 pF
COUT Output
Capacitance
VOUT = 0V 8 12 pF
2619 lnk 04
2619 lnk 03
NOTE:
1. This parameter is measured at characterization but not tested.