Daikin RTD-NET Installation manuals [es]

0 (0)

RTD-NET

Instrucciones de instalación

Español RTD-NET Instrucciones de instalación

0V

+V

POWER

15-24VDC

 

 

 

 

 

 

 

 

RTD-NET

realtime

100.00

 

Control Interface

Control Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMCON

 

 

RS485 D-BUS

 

 

P1

P2

 

 

DB

DA

GND

 

 

 

 

 

+

 

 

-

 

 

 

 

 

SW1

ON

 

 

 

 

 

 

 

LED1

 

LED2

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

LED3

LED4

1

J2

100.00

22.00

All dimensions in mm

realtime

Control Systems

Ø 4.00

90.00

90.00

 

RED

 

 

BLUE

 

+V

0V

 

X18A/X35A

 

VRV

 

 

Indoor

0V

+V

PCB

POWER

 

15-24VDC

Ø 5.00

88.00

78.00

 

RED

 

BLUE

+V

0V

X35A

 

Skyair

 

Indoor

0V +V

PCB

POWER

 

15-24VDC

P1

P2

P1

P2

P1

P2

RTD

P1

P2

ADDRESS 0

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

RS485 D-BUS

 

 

 

 

 

DB

DA GND

 

 

 

 

+

-

 

 

 

 

DB(+)DB(+)

DA(-) DA(-)

GND GND

ADDRESS 1

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

RS485 D-BUS

 

 

 

 

 

DB

DA GND

 

 

 

 

+

-

 

 

 

 

 

 

2

18870-1.06.03 RTD-NET Installation Instructions

Daikin RTD-NET Installation manuals

LED2 LED1

ADDRESS 0

ON

1

2

3

4

5

6

7

8

ADDRESS 8

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 16

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 24

ON

1

2

3

4

5

6

7

8

ADDRESS 32

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 40

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 48

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 56

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 1

ON

1

2

3

4

5

6

7

8

ADDRESS 9

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 17

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 25

ON

1

2

3

4

5

6

7

8

ADDRESS 33

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 41

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 49

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 57

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 2

ON

1

2

3

4

5

6

7

8

ADDRESS 10

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 18

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 26

ON

1

2

3

4

5

6

7

8

ADDRESS 34

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 42

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 50

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 58

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 3

ON

1

2

3

4

5

6

7

8

ADDRESS 11

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 19

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 27

ON

1

2

3

4

5

6

7

8

ADDRESS 35

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 43

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 51

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 59

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 4

ON

1

2

3

4

5

6

7

8

ADDRESS 12

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 20

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 28

ON

1

2

3

4

5

6

7

8

ADDRESS 36

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 44

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 52

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 60

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 5

ON

1

2

3

4

5

6

7

8

ADDRESS 13

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 21

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 29

ON

1

2

3

4

5

6

7

8

ADDRESS 37

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 45

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 53

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 61

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 6

ON

1

2

3

4

5

6

7

8

ADDRESS 14

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 22

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 30

ON

1

2

3

4

5

6

7

8

ADDRESS 38

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 46

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 54

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ADDRESS 62

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

LED2

 

ADDRESS 7

 

LED1

ON

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

ADDRESS 15

 

 

ON

 

 

 

 

 

 

LED2

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

LED1

 

ADDRESS 23

 

 

 

 

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

ADDRESS 31

 

LED2

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

LED1

 

 

ADDRESS 39

 

 

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

LED2

 

ADDRESS 47

 

 

 

LED1

ON

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

ADDRESS 55

 

 

ON

 

 

 

 

 

 

LED2

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

LED1

 

ADDRESS 63

 

 

 

 

ON

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

LED2

LED1

LED2 LED1

18870-1.06.03 RTD-NET Installation Instructions

3

Precauciones y advertencias

Todas las conexiones de cables al dispositivo deben asegurarse adecuadamente a través de fijadores de alivio de tensión

La RTD debe montarse en una caja de metal o de plástico adecuada con una clasificación de inflamabilidad de al menos IEC60695-11-10

V-1. No la instale dentro de la unidad de climatización. En cualquier caso se debe evitar que personas no cualificadas accedan a la caja (puede que no se pueda acceder a la caja sin una herramienta). La unidad se puede montar en vertical o en horizontal

Cuando la RTD se enciende a partir del suministro eléctrico de la unidad interior u otro suministro que no sea de tensión extra-baja de seguridad, todo el cableado externo y los dispositivos fijados eléctricamente deben aislarse adecuadamente para evitar el acceso de personas no cualificadas. Cuando no sea posible, la RTD recibirá la alimentación de un suministro de tensión extra-baja de seguridad.

Los cables RS485 deben ser cables de par trenzado 24awg blindados o no blindados con las especificaciones Cat3, Cat4 o Cat5. Utilice un par trenzado para las conexiones DB, DA y un núcleo adicional para la conexión GND. Instale el cable RS485 tal y como se muestra en la Figura 4.

La red P1, P2 debe conectarse tal y como se muestra en la Figura 3. A la RTD se pueden conectar hasta 16 unidades y un mando a distancia.

Especificaciones

Eléctricas

15V-24V CC, 120mA

Medioambientales

 

 

 

AlimentaciónRegulada

Temperatura

 

Potencia

<2,5VA

Almacenamiento-10 °C a 50 °C

Conectores

Abrazadera al cable de

Funcionamiento0 °C a 50 °C

0,75mm2

 

 

Humedad

0-90% HR

 

 

sin condensación

 

 

 

Red

 

 

 

P1P2

< 500m

 

 

RS485

< 500m

 

 

El producto está marcado con el símbolo que aparece a la izquierda. El símbolo del producto indica que este producto no debe desecharse junto con los demás residuos domésticos. Su eliminación inadecuada puede ser dañina. Es su responsabilidad desechar los equipos entregándolos en un punto de recogida específico para el reciclaje de equipos eléctricos y electrónicos. Los sistemas de climatización deberán tratarse en instalaciones especializadas para poder reutilizar, reciclar y recuperar sus componentes. Si se asegura de desechar el producto correctamente, ayudará a evitar las consecuencias negativas que estos residuos podrían suponer para el medio ambiente y la salud humana. Para más información, póngase en contacto con un instalador o las autoridades locales.

Observe las precauciones durante el manejo de dispositivos sensibles electroestáticos

Hay disponible información adicional, que incluye códigos de avería en www.realtime-controls.co.uk/rtd

4

ES

18870-1.06.03 RTD-NET Installation Instructions