Siemens S8 PCN, S6 Power PCN Service Manual

0 (0)

Private Communication Systems

Mobile Phones

S6 Power PCN

S8 PCN

Level 2.5

Repair Documentation

V 1.1

V1.1

Page 1 of 23

PN MP ST

D. Schnoor

08/98

Private Communication Systems

Mobile Phones

Table of Contents:

 

1 INTRODUCTION ................................................................................................................................................

3

2 TCXO

 

...................................................................................................................................................................................

4

3 FUSE 1A

 

...................................................................................................................................................................................

8

4 FUSE 0.25 A

 

.................................................................................................................................................................................

11

5 MOLEX CONNECTOR

 

.................................................................................................................................................................................

16

6 RINGER

 

.................................................................................................................................................................................

20

V1.1

Page 2 of 23

PN MP ST

D. Schnoor

08/98

Private Communication Systems

Mobile Phones

1Introduction

This manual is intended to help you carry out S6 power PCN repairs on level 2.5, meaning limited component repairs. Failure highlights are documented and should be repaired in the local workshops.

The S8 PCN uses the same MMI and RF/Control module as the S6 power PCN but has a different casing.

It must be noted that all repairs have to be carried out in an environment set up according to the ESD (Electrostatic Discharge Sensitive Devices) regulations defined in international standards.

If you have any questions regarding the repair procedures or spare parts do not hesitate to contact our technical support team in Kamp-Lintfort, Germany:

Tel.: +49 2842 95 4666

Fax: +49 2842 95 4302

e-mail: dominik.schnoor@klf.siemens.de

V1.1

Page 3 of 23

PN MP ST

D. Schnoor

08/98

Private Communication Systems

Mobile Phones

2TCXO

2.1Affected Units

 

2.1.1Type:

S6 Power PCN

2.1.2Affected IMEIs / Date Codes: All / All

 

2.1.3Affected SW-Versions:

All

2.1.4Fault Code for LSO reporting:

3TCX

2.2Fault Description

2.2.1Fault Symptoms for customers:

Network Search

Handset not logging into network

2.2.2Fault Symptom on GSM-Tester:

Frequency error in synchronized mode >90 Hz

No location update possible

The TCXO (Temperature Compenseated Crystal Oscillator) is responsible for generating the

13 MHz reference frequency of the handset.

If it is defective, the handset cannot synchronize to the base station anymore.

2.3Priority:

........ Mandatory

........ Repair

........ Optional

V1.1

Page 4 of 23

PN MP ST

D. Schnoor

08/98

Private Communication Systems

Mobile Phones

........ Not Yet Defined

2.4Repair Documentation

2.4.1Description of procedure:

2.4.1.1Diagnosis

Check the output frequency of the TCXO using the level-2 testing program for S6 Power PCN.

Set the „Simulator“ option in the S611.INI file to 0 and restart

the program. Start the test, when the program says „Check power and phase of external antenna with your GSM-Tester“, switch the CMD to „LOCAL“ mode and enter the „MODULE TEST“.

On the CMD display you can see the frequency error of the handset. (Make sure that the CMD is on channel 124, power level 5!)

If the frequency error is higher than 2kHz, the TCXO has to be replaced.

2.4.1.2Repair by component change

Use hot air blower to remove defective TCXO.

Avoid excessive heat!

Watch surrounding components!

Resolder new TCXO afterwards.

2.4.1.3Repair by SW-Booting

Not possible!

2.4.1.4Test

Retest handset after repair as described above. The frequency error must now be < 2kHz.

V1.1

Page 5 of 23

PN MP ST

D. Schnoor

08/98

Private Communication Systems

Mobile Phones

2.4.2List of needed material

2.4.2.1Components

TCXO

Part-Number: L36145-G300-Y19

2.4.2.2Jigs and Tools

Hot Air Blower

Soldering Iron

2.4.2.3Special Tools

None

2.4.2.4Working materials

Desolder Wick / Braid

Solder

V1.1

Page 6 of 23

PN MP ST

D. Schnoor

08/98

Siemens S8 PCN, S6 Power PCN Service Manual

Private Communication Systems

Mobile Phones

2.4.3Drawings

Figure 1: S6 Power PCN Board TCXO Side

Figure 2: TCXO (Z601) Placement (Top View)

V1.1 Page 7 of 23 PN MP ST

D. Schnoor

08/98