Motorola SN54LS168J, SN54LS169J, SN74LS168D, SN74LS168N, SN74LS169D Datasheet

...
0 (0)
Q0 Q1 Q2 Q3
14 13 12 11
VCC = PIN 16 GND = PIN 8

BCD DECADE/MODULO

16 BINARY SYNCHRONOUS BI-DIRECTIONAL COUNTERS

The SN54/74LS168 and SN54/74LS169 are fully synchronous 4-stage up/down counters featuring a preset capability for programmable operation, carry lookahead for easy cascading and a U/D input to control the direction of counting. The SN54/74LS168 counts in a BCD decade (8, 4, 2, 1) sequence, while the SN54/74LS169 operates in a Modulo 16 binary sequence. All state changes, whether in counting or parallel loading, are initiated by the LOW-to-HIGH transition of the clock.

Low Power Dissipation 100 mW Typical

High-Speed Count Frequency 30 MHz Typical

Fully Synchronous Operation

Full Carry Lookahead for Easy Cascading

Single Up/Down Control Input

Positive Edge-Trigger Operation

Input Clamp Diodes Limit High-Speed Termination Effects

CONNECTION DIAGRAM DIP (TOP VIEW)

VCC

 

TC

Q0

 

Q1

 

Q2

Q3

 

CET

PE

 

16

 

15

 

14

 

13

 

12

 

11

 

10

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Flatpak version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

has the same pinouts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Connection Diagram) as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Dual In-Line Package.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

 

 

U/D

 

CP

P0

 

P1

 

P2

P3

 

CEP

GND

PIN NAMES

LOADING (Note a)

 

 

 

 

 

HIGH

LOW

 

 

 

 

 

 

 

 

 

CEP

Count Enable Parallel (Active LOW) Input

0.5

U.L.

0.25

U.L.

CET

Count Enable Trickle (Active LOW) Input

1.0

U.L.

0.5

U.L.

CP

Clock Pulse (Active positive going edge) Input

0.5

U.L.

0.25

U.L.

PE

Parallel Enable (Active LOW) Input

0.5

U.L.

0.25

U.L.

 

 

 

 

 

 

 

 

U/D

Up-Down Count Control Input

0.5

U.L.

0.25

U.L.

P0±P3

Parallel Data Inputs

0.5

U.L.

0.25

U.L.

Q0±Q3

Flip-Flop Outputs

10

U.L.

5 (2.5)

U.L.

TC

Terminal Count (Active LOW) Output

10

U.L.

5 (2.5)

U.L.

 

 

 

 

 

 

 

 

 

NOTES:

a.1 TTL Unit Load (U.L.) = 40 μA HIGH/1.6 mA LOW.

b.The Output LOW drive factor is 2.5 U.L. for Military (54) and 5 U.L. for Commercial (74)

b.Temperature Ranges.

SN54/74LS168

SN54/74LS169

BCD DECADE/MODULO 16 BINARY SYNCHRONOUS BI-DIRECTIONAL COUNTERS

LOW POWER SCHOTTKY

 

 

 

J SUFFIX

 

 

 

CERAMIC

 

 

 

CASE 620-09

16

1

 

 

 

 

 

 

 

 

N SUFFIX

 

 

 

PLASTIC

16

 

 

CASE 648-08

 

 

 

 

1

 

 

 

 

 

D SUFFIX

 

16

 

SOIC

 

 

CASE 751B-03

 

 

1

 

 

 

ORDERING INFORMATION

SN54LSXXXJ Ceramic

SN74LSXXXN Plastic

SN74LSXXXD SOIC

LOGIC SYMBOL

9 3 4 5 6

PE P0 P1 P2 P3

1U/D

7

CEP

TC

15

10

CET

 

 

2CP

FAST AND LS TTL DATA

5-302

Motorola SN54LS168J, SN54LS169J, SN74LS168D, SN74LS168N, SN74LS169D Datasheet

SN54/74LS168 SN54/74LS169

 

 

 

 

 

STATE DIAGRAMS

 

 

 

 

 

 

SN54/ 74LS168

 

 

 

SN54 / 74LS169

 

UP / DOWN DECADE COUNTER

 

 

 

 

 

 

0

1

2

3

4

 

0

1

2

3

4

15

 

 

 

5

 

15

 

 

 

5

14

 

 

 

6

Count Up

14

 

 

 

6

 

 

 

Count Down

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

7

 

13

 

 

 

7

12

11

10

9

8

 

12

11

10

9

8

SN54 / 74LS168

 

 

 

 

SN54 / 74LS169

 

 

 

UP:

TC = Q0 Q3 (U / D)

 

 

UP:

TC = Q0 Q1 Q2 Q3 (U / D)

DOWN:

TC = Q0 Q1 Q2 Q3 (U / D)

 

DOWN:

TC = Q0 Q1 Q2 Q3 (U / D)

 

 

 

LOGIC DIAGRAMS

 

 

 

 

SN54 / 74LS168

 

 

P0

P1

P2

P3

PE

 

 

 

 

CEP

 

 

 

 

CET

 

 

 

 

U/D

 

 

 

 

 

 

 

 

TC

CP

 

 

 

 

CP

D

 

 

 

 

Q0

Q1

Q2

Q3

FAST AND LS TTL DATA

5-303

 

 

SN54/74LS168 SN54/74LS169

 

 

 

 

LOGIC DIAGRAMS (continued)

 

 

 

 

SN54 / 74LS169

 

 

P0

P1

P2

P3

PE

 

 

 

 

CEP

 

 

 

 

CET

 

 

 

 

U/D

 

 

 

 

 

 

 

 

TC

CP

 

 

 

 

CP

D

 

 

 

 

Q0

Q1

Q2

Q3

GUARANTEED OPERATING RANGES

Symbol

Parameter

 

Min

Typ

Max

Unit

 

 

 

 

 

 

 

VCC

Supply Voltage

54

4.5

5.0

5.5

V

 

 

74

4.75

5.0

5.25

 

 

 

 

 

 

 

 

TA

Operating Ambient Temperature Range

54

± 55

25

125

°C

 

 

74

0

25

70

 

 

 

 

 

 

 

 

IOH

Output Current Ð High

54, 74

 

 

± 0.4

mA

IOL

Output Current Ð Low

54

 

 

4.0

mA

 

 

74

 

 

8.0

 

 

 

 

 

 

 

 

FAST AND LS TTL DATA