PANASONIC WHUD24BE5, WHSD24BE5, WHSD30BE5, WHUD30BE5 User Manual [da, en, no, fi, sv]

0 (0)

F566899

Operating Instructions

Air-to-Water Heatpump

Indoor Unit

Outdoor Unit

WH-SD24BE5 WH-UD24BE5

WH-SD30BE5

WH-UD30BE5

ENGLISH

2

~ 9

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

 

 

Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and

 

 

precisely following the installation instructions given.

 

 

SVENSKA

10

~ 17

Innan du använder enheten, läs noga igenom denna bruksanvisning och spara den för framtida bruk.

 

 

Innan du använder enheten, se till att installationen har utförts noggrant och korrekt av auktoriserad återförsäljare som

 

 

följt de givna installationsinstruktionerna.

 

 

NORSK

18

~ 25

Les bruksanvisningen nøye før du bruker denne enheten, og oppbevar den for fremtidig bruk.

 

 

Før du bruker enheten, må du forsikre deg om at autorisert forhandler har utført korrekt og presis installasjon og har

 

 

fulgt installasjonsinstruksjonene som er gitt.

 

 

SUOMI

26

~ 33

Lue nämä käyttöohjeet huolellisesti ennen yksikön käyttämistä ja säilytä ne tulevaisuutta varten.

 

 

Varmista ennen laitteen käyttöä, että asennuksen on suorittanut valtuutettu jälleenmyyjä ja että se on tehty oikein ja

 

 

tarkasti annettuja asennusohjeita noudattaen.

 

 

DANSK

34

~ 41

Læs brugsanvisningen grundigt igennem før du benytter anlægget og gem den til fremtidig brug.

 

 

Sørg for, at anlægget er installeret korrekt af en autoriseret forhandler i overensstemmelse med de følgende

 

 

instruktioner, før anlægget tages i brug.

 

 

© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2009. Unauthorized copying and distribution is a violation of law.

1F566899_OYTH0907-00_1EN.indd 1

8/19/2009 5:25:53 PM

PANASONIC WHUD24BE5, WHSD24BE5, WHSD30BE5, WHUD30BE5 User Manual

Thank you for purchasing Panasonic Product

TABLE OF CONTENTS

SAFETY PRECAUTIONS

2~3

PRODUCT OVERVIEW

4

BASIC OPERATION

5

ADVANCE OPERATION

6

CARE & CLEANING

7

TROUBLESHOOTING

8

INFORMATION

9

NOTE :

The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for

SAFETY PRECAUTIONSI

Notes :

Panasonic Air-to-Water Heatpump is a split system consisting only of an indoor unit and an outdoor unit. This system designed for combination with Panasonic Tank Unit. In case of non-Panasonic Tank Unit is being used with Panasonic Air-to-Water Heatpump System, Panasonic cannot guarantee neither good operation nor reliability of the system.

This manual describes how to operate the Heatpump system between indoor and outdoor units only.

Other operation such as water tank, radiator and underfloor system, please refer to respective manufacturer operation manuals.

OPERATION CONDITION

 

 

 

Indoor

Outdoor

 

 

 

 

 

 

Water outlet

Ambient

 

 

temperature (°C)

temperature (°C)

 

 

 

 

HEATING

Maximum

55

35

Minimum

25

-20

 

NOTICE : When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly and outdoor unit might stop for protection control.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

Indoor Unit

Power Supply

 

Outdoor Unit

Air inlet

Air inlet

Air outlet

2

1F566899_OYTH0907-00_1EN.indd 2

8/19/2009 5:25:55 PM

DEFINITION

 

The instructions to be followed are classified by the following symbols:

 

This symbol denotes an action

These symbols denote actions

that is PROHIBITED.

that are COMPULSORY.

To prevent personal injury, injury to others, or property damage, please comply the following.

Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classified as below:

Warning

This sign warns of death or

Caution

This sign warns of injury or

 

serious injury.

 

damage to property.

ENGLISH

Indoor Unit

Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fire. Please consult authorized dealer for the installation work.

Do not attempt to repair the unit by yourself. Otherwise, it may cause injury if it is mishandling.

Do not install the unit at outdoor. This is designed for indoor installation only.

This unit is equipped with Residue Current Circuit Breaker (RCCB). It is strongly recommended to check the operation of the RCCB after installation and periodically after servicing or maintenance by authorized dealer to ensure it is in good working order. Otherwise, it may cause electrical shock or fire in case of malfunction.

The equipment must be earthed to prevent electrical shock or fire.

Power Supply

Do not share the same power outlet with other equipment.

Do not modify power cords.

Do not use extension cords.

Do not operate with wet hands.

Use the specified power supply cord.

If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.

In case of emergency or presence of abnormal

conditions (burnt smell, etc), turn off the power supply, and consult authorized dealer.

Outdoor Unit

• Do not insert your fingers or other objects into the unit, rotating parts may cause injury.

Indoor Unit

Do not install the unit in a potentially explosive atmosphere.

Do not install the unit close to any combustible equipment or at bathroom. Otherwise, it may cause electric shock or fire.

Do not touch the water discharge pipe at the indoor unit during operation.

Do not place anything on top or beneath of the unit.

Ensure that the drainage pipe is connected properly.

Otherwise, leakage may occur.

Control Panel

Do not let the control panel get wet. Otherwise, it may cause electric shock or fire.

Do not press the buttons on the control panel with hard, pointed objects. Otherwise, it may damage the unit.

Do not wash the control panel with water, benzene, thinner or scouring powder.

Do not inspect or service the control panel by yourself. Please consult authorized dealer. Otherwise, it may cause injury if mishandling.

Power Supply

• Switch off the power supply before cleaning or servicing.

• Turn off the power supply if the unit is not used for a long period of time.

This unit is equipped with a built-in surge protective device. However, in order to further protect your unit from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the unit during lightning, it may cause electric shock.

It is recommended to wear gloves during servicing

or maintenance in order to avoid hazard.

Outdoor Unit

• Do not sit or step on the unit, you may fall down accidentally.

• Do not touch the sharp aluminium fin, sharp parts may cause injury.

Check the installation rack periodically to make sure that it is not damaged. After long periods of

use, the strength of the installation rack may have deteriorated.

3

1F566899_OYTH0907-00_1EN.indd 3

8/19/2009 5:25:55 PM

PRODUCT OVERVIEW

Air-to-Water Heatpump

Indoor Unit

Water Pressure Gauge

 

 

• Do not press or hit the glass

 

 

cover with hard, pointed

 

0.2

objects. This may damage the

0.1

0.3

unit.

 

0

0.4

• Ensure that the water

 

MPa

pressure is between 0.05 to

 

 

0.2MPa.

 

 

• In case the water pressure is

 

 

out of the above range, please

 

 

consult authorized dealer.

Control Panel

 

 

 

 

 

 

 

12

13

14

 

 

 

 

 

 

 

 

11

WATER OUTLET

OUTDOOR

 

10

Open the cover to

HEAT

 

 

 

 

 

C

 

C

 

use the buttons

 

 

 

 

 

 

 

 

SETTING

9

 

 

 

 

 

 

 

 

C

 

STATUS

 

 

 

 

 

 

 

 

 

PUMPDW

8

 

 

 

OUTD

OOR

 

1

WATER INLET

ERROR

 

 

ER OUTLET

 

 

 

WAT

 

C

SETTING

 

OFF / ON

 

 

 

 

 

 

HEAT

 

C

 

 

STATUS

 

 

 

 

 

PUMPDW

 

 

 

 

C

ERROR

 

 

 

 

 

7

WATER

INLET

 

 

 

 

 

 

 

 

OFF / ON

 

 

 

2

 

 

 

STATUS

 

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

SET

CHECK

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT

 

SEARCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

CANCEL

ERROR

PUMPDW

 

 

 

 

 

 

 

 

RESET

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

1

OFF/ON Button

8

System Pumpdown Mode Indicator

2

Operation LED

9

System Status Check Mode Indicator

3

System Setting Mode Buttons

10

System Setting Mode Indicator

4

Error Reset Button

11

Heating Operation Indicator

5

System Status Check Mode Buttons

12

Water Outlet Temperature Display

6

System Pumpdown Mode Button

13

Water Inlet Temperature Display

7

System Error Display

14

Outdoor Ambient Temperature Display

4

1F566899_OYTH0907-00_1EN.indd 4

8/19/2009 5:25:56 PM

BASIC OPERATION

ENGLISH

Operation Start / Stop

 

 

The unit starts by pressing OFF / ON

.

WATER INLET

ERROR

• When unit is ON, operation LED is lit and the actual

OFF / ON

 

 

 

 

temperature for water outlet, water inlet and outdoor

SETTING

STATUS

 

ambient are shown on the control panel display.

 

 

 

 

SET

CHECK

Press OFF / ON

again to stop the operation.

 

 

Operation details (Default setting)

Operation takes place under default settings as follows:

-When Outdoor ambient temperature (Out Lo) is less than 0°C, water outlet set temperature (H2O Lo) is 50°C.

-When Outdoor ambient temperature (Out Hi) is more than 15°C, water outlet set temperature (H2O Hi) is 32°C.

In between the specified outdoor ambient temperature range (Out Lo and Out Hi), the system will automatically adjust the water outlet temperature between specified range (H2O Lo and H2O Hi).

Lower outdoor ambient temperature will result in higher water outlet temperature and vice versa.

Optional Settings

ERROR

Error code reset

 

RESET

• Not usable during normal operation.

 

 

 

PUMPDW

System Pump Down

 

• Not usable during normal operation.

 

 

 

 

• If accidentally pressed the PUMPDW, press OFF / ON

to stop the pump down operation.

5

1F566899_OYTH0907-00_1EN.indd 5

8/19/2009 5:25:56 PM

ADVANCE OPERATION

Recommendation

It is strongly recommended to have the authorized dealer to change the water temperature range. The temperature range for water outlet temperature and outdoor ambient temperature could be set by control panel.

Perform the steps below to set preferred temperature range.

1 , 5

 

 

SETTING

STATUS

 

 

SET

CHECK

2 , 4

 

SELECT

SEARCH

 

 

ERROR

 

 

 

CANCEL RESET

PUMPDW

 

 

 

3

STEP 1: Press SET

for 5 seconds to enter SETTING mode. “SETTING” indicator is ON.

STEP 2: Press

or

to choose a parameter.

 

H2O Lo: Water outlet set

HEAT

Selection range:

temperature at low outdoor

 

C

25°C ~ 55°C

ambient set temperature

 

SETTING

 

 

STATUS

 

 

PUMPDW

H2O Hi: Water outlet set

HEAT

Selection range:

temperature at high outdoor

 

C

25°C ~ 55°C

ambient set temperature

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Lo: Low outdoor

HEAT

Selection range:

ambient set temperature

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Hi: High outdoor

HEAT

Selection range:

ambient set temperature

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Note: Please make sure High outdoor ambient set temperature (Out Hi) is always higher than Low outdoor ambient set temperature (Out Lo).

STEP 3: After selecting the desired parameter, press

SELECT

” indicator will blink when a

to enter the parameter. “

parameter is selected.

 

 

STEP 4: Press or to set the desired temperature.

STEP 5: Press SET again to confirm the setting.

Repeat steps 2 to 5 to set other parameters.

Press CANCEL or wait 30 seconds to exit SETTING mode.

The setting temperature will be stored in the system once confirm.

“SETTING” mode cannot be activated when the “PUMPDW” and “STATUS” indicator is ON.

6

1F566899_OYTH0907-00_1EN.indd 6

8/19/2009 5:25:58 PM

CARE & CLEANING

• Switch off the power supply before cleaning.

CAUTION

Indoor Unit & Control Panel

Do not splash water directly.

Wipe the unit gently with a soft, dry cloth.

Outdoor Unit

Do not obstruct the air inlet and air outlet vents, it may cause low performance or breakdown. Please remove obstacles to assure the ventilation.

During winter, please clean and remove the snow near outdoor unit so that the snow does no cover the air inlet and air outlet vents.

Inspection

In order to ensure optimal performance of the unit, seasonal inspections on the unit and field wiring have to be carried out at regular intervals. This maintenance should be carried out by authorized dealer.

Clear any obstruction at the air inlet and air outlet vents of outdoor unit.

For Extended Non-Use

• Turn off the power supply.

Perform the steps below to check system status

 

 

 

1

SETTING

 

STATUS

 

SET

 

CHECK

 

SELECT

 

SEARCH

2

 

 

 

CANCEL

ERROR

PUMPDW

 

RESET

 

ENGLISH

STEP 1:

Press

CHECK for 5 seconds to enter STATUS mode.

STEP 2:

Press

or

to check the Compressor Running Frequency or Error History.

Press CANCEL or wait 30 seconds to exit STATUS mode.

Once STATUS mode is entered, “STATUS” indicator is ON.

STATUS mode cannot be activated when the “SETTING” indicator is ON.

7

1F566899_OYTH0907-00_1EN.indd 7

8/19/2009 5:25:58 PM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The following symptoms do not indicate malfunction.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

Cause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water flowing sound during operation.

• Refrigerant flow inside the unit.

 

 

 

 

 

Operation is delayed a few minutes after

• The delay is a protection to the unit’s compressor.

 

 

 

 

restart.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit emits water/steam.

• Condensation or evaporation occurs on pipes.

 

 

 

 

Outdoor unit emits steam during heating

• This is due to defrost operation happens at the heat exchanger.

 

 

 

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit does not operate.

• When the outdoor temperature is out of the operation condition range,

 

 

 

 

 

 

 

 

 

 

 

 

 

the heatpump system enter protection control.

 

System difficult to heat-up.

When heating is operated by indoor unit together with floor heating or panel heater simultaneously, there may be case where warm water temperature is getting lower and cause floor heating or panel heater heat-up is weaken.

When outdoor air temperature is low, it may be difficult to get warm.

Is the snow pile blocking the discharge outlet or intake inlet of outdoor unit.

When water outlet set temperature is low, it may be difficult to get warm.

System cannot get warm instantly.

Operation starts after power resumes.

Due to the nature of the heatpump system, it may take some time to heat-up the water if the unit is operated from cold-start.

Auto restart is in function and operates under.

Check the following before calling for servicing.

Symptom

Check

 

 

 

Heating operation is not working efficiently.

Set the temperature correctly.

 

Is the panel heater valve closed.

 

Clear any obstruction at the air inlet and air outlet vents of outdoor unit.

Noisy during operation.

Check if the unit has been installed at an incline or the cover is not

 

 

closed properly.

The unit does not work.

Operation LED is no lit or control panel display is blank.

Check if the circuit breaker is tripped.

Is the power supply off or power failure.

The operation LED blinks and error code appear on control panel display

C

C

C

 

WATER INLET

ERROR

• Turn the unit off and reveal the error code to authorized dealer.

8

1F566899_OYTH0907-00_1EN.indd 8

8/19/2009 5:25:59 PM

INFORMATION

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:

Abnormal noise during operation.

Water/foreign particles have entered the control panel.

Water leaks from Indoor unit.

Circuit breaker switches off frequently.

Power cord becomes unnaturally warm.

Switches or buttons are not functioning properly.

Information for Users on Collection and Disposal of Old Equipment

These symbols on the products, packaging, and/or accompanying documents mean that used electrical and

electronic products should not be mixed with general household waste.

For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.

By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling.

For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items.

Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

For business users in the European Union

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.

[Information on Disposal in other Countries outside the European Union]

These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.

ENGLISH

9

1F566899_OYTH0907-00_1EN.indd 9

8/19/2009 5:25:59 PM

Tack för ditt inköp av

Panasonic -produkt

INNEHÅLLSFÖRTECKNING

SÄKERHETSFÖRESKRIFTER

10~11

PRODUKTÖVERSIKT

12

GRUNDLÄGGANDE ANVÄNDNING 13

AVANCERAD ANVÄNDNING

14

UNDERHÅLL & RENGÖRING

15

PROBLEMLÖSNING

16

INFORMATION

17

OBS :

Bilderna i denna skötselanvisning är endast illustrativa och kan därför skilja sig från den faktiska modellen. Förändringar kan göras utan föregående meddelande angående framtida förbättringar.

SÄKERHETSFÖRESKRIFTERI

OBS :

Panasonics Luft-till-Vatten-Värmepump är ett split-system som består av endast en inomhusenhet och en utomhusenhet. Det här systemet är tillverkat för att användas med Panasonics ackumulatortank. Om du använder Panasonics Luft-till-Vatten-Värmepump med en ackumulatortank från en annan tillverkare än Panasonic, kan Panasonic varken garantera god prestanda eller tillförlitlig drift.

I denna manual beskrivs hur du använder värmepumpsystemet mellan inomhusoch utomhusenheterna enbart.

För annan användning av t.ex. vattentank, värmeelement och golvvärmesystem, se bruksanvisningen från respektive tillverkare.

TILLÅTNA DRIFTSFÖRHÅLLANDEN

 

 

 

 

 

 

Inomhus

Utomhus

 

 

Vattenutloppstemperatur

Omgivningstemperatur

 

 

(°C)

(°C)

 

 

 

 

VÄRME

Max.

55

35

 

 

 

Min.

25

-20

 

MÄRK : Då utomhustemperaturen är utanför temperaturområdet ovan, sjunker uppvärmningskapaciteten avsevärt och utomhusenheten kan stoppa för skyddskontroll.

Denna apparat är inte ämnad att användas av personer (inklusive barn) med fysiska, sensoriska eller mentala hinder, eller med otillräcklig erfarenhet eller kunskap, om de inte övervakas eller fått instruktioner angående användandet av apparaten av en person som är ansvarig för deras säkerhet. Barn skall övervakas så att de inte leker med apparaten.

Inomhusdel Strömförsörjning

Utomhusdelen

Luftintag

Luftintag

Utblåsning

10

1F566899_OYTH0907-00_2SV.indd 10

8/19/2009 5:37:18 PM

DEFINITIONER

Instruktioner klassificeras med följande symboler:

Denna symbol betecknar en

Dessa symboler betecknar

handlingar som MÅSTE

handling som är FÖRBJUDEN.

FÖLJAS.

 

Observera följande för att förhindra personoch egendomsskador.

Felaktig användning orsakad av att skötselanvisningen inte följts kan leda till skador, nedan klassas deras allvar:

Varning

Denna symbol varnar för

Försiktighet

Denna symbol varnar för

personskada eller skada på

 

dödsfara eller allvarliga skador.

 

egendom.

 

 

 

Inomhusdel

Installera inte, avlägsna inte och återinstallera inte enheten själv; oriktig installation kan orsaka läckage, elstöt eller eldsvåda. Var god rådfråga auktoriserad återförsäljare om installationsarbete.

Försök inte reparera enheten på egen hand. Detta kan i så fall orsaka personskada, om det görs på fel sätt.

Installera inte enheten utomhus. Den är endast utformad för installation inomhus.

Denna enhet är utrustad med Jordfelsskydd (RCCB). Du rekommenderas starkt att kontrollera RCCB:ns drift efter installationen och med

jämna mellanrum efter service eller underhåll av auktoriserad återförsäljare för att försäkra dig om att den är i gott skick. Annars kan den orsaka elstöt eller eldsvåda, ifall fel uppstår på den.

Utrustningen måste jordas för att förhindra elstötar och brand.

Strömförsörjning

Dela inte samma uttag eller säkring med annan utrustning.

Ändra inte på elkablar.

Använd inte skarvkablar.

Ta inte i värmepumpen med våta händer.

Använd den specificerade anslutningskabeln.

Om anslutningskabeln är skadad, måste den bytas ut av tillverkaren, dess serviceagentur, eller liknande kvalificerade personer för att undvika fara.

Vid nödfall eller onormala förhållanden

(lukten av bränt, etc), stäng av strömmen, och rådfråga auktoriserad återförsäljare.

Utomhusdelen

• För inte in dina fingrar eller andra föremål i enheten, eftersom roterande delar kan orsaka personskada.

Inomhusdel

Installera inte värmepumpen i explosiv miljö.

Installera inte enheten nära någon antändbar utrustning eller i våtrum. Det finns i så fall risk för elstöt eller eldsvåda.

Rör inte utgående varmvattenrör vid inomhusenheten under användning.

Ställ ingenting ovanpå eller under enheten.

Se till att dräneringsslangen är korrekt ansluten.

Annars kan läckage uppstå.

Kontrollpanel

Låt inte kontrollpanelen bli våt. Det finns i så fall risk för elstöt eller eldsvåda.

Tryck inte på knapparna på kontrollpanelen med hårda, spetsiga föremål. Det kan i så fall orsaka skada på enheten.

Tvätta inte kontrollpanelen med vatten, bensen, thinner eller skurningspulver.

Utför inte kontroll eller service av kontrollpanelen själv. Var god rådfråga auktoriserad återförsäljare. Detta kan annars orsaka personskada, om det görs på fel sätt.

Strömförsörjning

• Slå ifrån strömmen innan rengöring eller service. • Slå ifrån strömmen om enheten inte ska användas

under en längre tid.

Denna enhet är utrustad med ett inbyggt överspänningsskydd. Men, för att ytterligare skydda din enhet från att skadas vid onormalt starka åskoväder, kan du stänga av strömmen. Rör inte enheten under åskoväder, då det kan orsaka elstöt.

Det rekommenderas att man har på sig handskar

under service och underhåll för att undvika skada.

Utomhusdelen

• Sitt inte och ställ dig inte på enheten, eftersom du då kan trilla och skada dig.

• Rör inte den vassa aluminiumflänsen, eftersom vassa delar kan orsaka personskada.

Kontrollera installationskonsollerna med jämna mellanrum för att vara säker på att inga skador

uppstått. Efter längre användningsperioder, kan installationskonsollernas styrka ha försvagats.

SVENSKA

11

1F566899_OYTH0907-00_2SV.indd 11

8/19/2009 5:37:19 PM

PRODUKTÖVERSIKT

Luft/Vatten Värmepump

Inomhusdel

Vattentrycksmätare

 

 

• Tryck inte och slå inte på

 

 

glaslocket med hårda,

 

0.2

spetsiga föremål. Detta kan

0.1

0.3

skada enheten.

 

0

0.4

• Se till så att vattentrycket är

 

MPa

mellan 0,05 till 0,2MPa.

 

 

• Ifall vattentrycket är utanför

 

 

området ovan, var god

 

 

rådfråga auktoriserad

 

 

återförsäljare

Kontrollpanel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

13

14

 

 

 

 

 

 

 

 

11

WATER OUTLET

OUTDOOR

 

10

Öppna locket för att

HEAT

 

 

 

 

 

C

 

C

 

använda knapparna

 

 

 

 

 

 

 

 

SETTING

9

 

 

 

 

 

 

 

 

C

 

STATUS

 

 

 

 

 

 

 

 

 

PUMPDW

8

 

 

 

OUTD

OOR

 

1

WATER INLET

ERROR

 

 

ER OUTLET

 

 

 

WAT

 

C

SETTING

 

OFF / ON

 

 

 

 

 

 

HEAT

 

C

 

 

STATUS

 

 

 

 

 

PUMPDW

 

 

 

 

C

ERROR

 

 

 

 

 

7

WATER

INLET

 

 

 

 

 

 

 

 

OFF / ON

 

 

 

2

 

 

 

STATUS

 

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

SET

CHECK

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT

 

SEARCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

CANCEL

ERROR

PUMPDW

 

 

 

 

 

 

 

 

RESET

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

1

Knappen OFF/ON

8

Utpumpningsindikator

2

Driftlampa

9

Systemstatusindikator

3

Lägesknappar

10

Lägesindikator

4

Knappen Felåterställning

11

Uppvärmningsindikator

5

Knappar för kontroll av systemstatus

12

Display för Utgående vattentemperatur

6

Utpumpningsknapp

13

Display för Inkommande vattentemperatur

7

Display för Systemfel

14

Display för Utetemperaturen

12

1F566899_OYTH0907-00_2SV.indd 12

8/19/2009 5:37:20 PM

GRUNDLÄGGANDE ANVÄNDNING

SVENSKA

Användning Start / Stopp

 

 

• Enheten startar om du trycker på OFF / ON

.

WATER INLET

ERROR

• Då enheten är på (ON), är driftlampan tänd och den

OFF / ON

 

faktiska temperaturen för utgående vattentemperatur,

 

 

inkommande vattentemperatur och utetemperaturen

SETTING

STATUS

visas på kontrollpaneldisplayen.

 

SET

CHECK

• Tryck på OFF / ON

 

 

 

 

igen för att stoppa driften.

Användningsdetaljer (Ursprungsinställning)

Användning med ursprungsinställningarna sker enligt följande:

-Då Utetemperaturen (Out Lo) är lägre än 0°C, är den inställda utgående vattentemperaturen (H2O Lo) 50°C.

-Då Utetemperaturen (Out Hi) är högre än 15°C, är den inställda utgående vattentemperaturen (H2O Hi) 32°C.

Inom det specificerade temperaturområdet för utetemperaturen (Out Lo och Out Hi), justeras utgående vattentemperatur automatiskt av systemet inom det specificerade området (H2O Lo och H2O Hi).

Lägre temperatur i utomhusomgivningen resulterar i högre utgående vattentemperatur och vice versa.

Valfria Inställningar

ERROR

Felkodsåterställning

 

RESET

• Kan inte användas under normal användning.

 

 

 

PUMPDW

“Pumpdown”

 

• Kan inte användas under normal användning.

 

 

 

 

• Om PUMPDW trycks in av misstag, tryck på OFF / ON

för att stoppa “Pumpdown”.

13

1F566899_OYTH0907-00_2SV.indd 13

8/19/2009 5:37:20 PM

AVANCERAD ANVÄNDNING

Rekommendation

Vi rekommenderar att en auktoriserad återförsäljare ändrar vattentemperaturområdet. Temperaturområdet för utgående vattentemperatur och utetemperaturen kan ställas in på kontrollpanelen.

Utför stegen nedan för att ställa in det önskade temperaturområdet.

1 , 5

 

 

 

SETTING

STATUS

 

 

 

SET

CHECK

2

, 4

 

SELECT

SEARCH

 

 

 

ERROR

 

 

 

 

CANCEL RESET

PUMPDW

 

 

 

 

3

STEG 1:

Tryck in SET

i 5 sekunder för att gå till läget SETTING. “SETTING”-indikatorn är på (ON).

STEG 2:

Tryck på

eller

för att välja en parameter.

 

H2O Lo: Inställd utgående

HEAT

Valområde:

vattentemperatur vid låg inställd

 

C

25°C ~ 55°C

utetemperatur

 

SETTING

 

 

STATUS

 

 

PUMPDW

H2O Hi: Inställd utgående

HEAT

Valområde:

vattentemperatur vid hög inställd

 

C

25°C ~ 55°C

utetemperatur

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Lo: Låg inställd

HEAT

Valområde:

utetemperatur

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Out Hi: Hög inställd

HEAT

Valområde:

utetemperatur

 

C

-15°C ~ 15°C

 

 

 

SETTING

 

 

STATUS

 

 

PUMPDW

Obs: Var god se till att Hög inställd utetemperatur (Out Hi) alltid är högre än Låg inställd utetemperatur (Out Lo).

STEG 3: Efter att du valt önskad parameter, tryck på

SELECT

” -indikatorn blinkar då en

för att gå till parametern. “

parameter är vald.

 

 

STEG 4: Tryck på eller för att ställa in den önskade temperaturen.

STEG 5: Tryck på SET igen för att bekräfta inställningen.

Repetera steg 2 till 5 för att ställa in andra parametrar.

Tryck på CANCEL eller vänta i 30 sekunder för att gå ur läget SETTING.

Inställningstemperaturen kommer att lagras i systemet efter att den bekräftats.

Läget “SETTING” kan inte aktiveras då “PUMPDW” -och “STATUS” -indikatorn är på (ON).

14

1F566899_OYTH0907-00_2SV.indd 14

8/19/2009 5:37:21 PM

Loading...
+ 30 hidden pages