ABB AB
Cewe-Control
SE-721 61 Vasteras Sweden
Tel: +46 21 32 07 00
Fax: +46 21 12 60 01
<![endif]>Revision C
8/8
Softstarter PSR60, PSR72, PSR85, PSR105
|
|
70mm(2.76’’) |
180mm(7.09’’) |
58mm(2.28’’) |
||||
|
|
1L1 |
|
3L2 |
|
5L3 |
|
|
|
|
|
|
|
ST A1 A2 |
|
|
|
|
|
|
|
PSR60-600-81 |
|
|
||
<![if ! IE]> <![endif]>220mm(8.66’’) |
<![if ! IE]> <![endif]>200mm(7.88’’) |
On |
Ready |
L1 |
L2 |
L3 |
<![if ! IE]> <![endif]>208mm(8.19’’) |
<![if ! IE]> <![endif]>198mm(7.80’’) |
Run |
TOR |
|
|
|
||||
|
|
U |
10 |
|
|
|
|
|
|
|
1 |
|
T1 |
T2 |
T3 |
|
|
|
|
20 |
|
|
|
|
|
|
|
|
U |
10 |
St ar t / |
|
|
|
|
|
|
0 |
|
|
|
|
||
|
|
|
|
St op 24 VDC |
|
|
||
|
|
20 |
|
|
|
|
|
|
|
|
40 |
55 |
ST |
A1(+) A2 |
|
|
|
|
|
70 |
Run Com TOR |
|
|
|||
|
|
|
|
|
|
Run Com TOR
2T1 |
4T2 |
6T3 |
6.2mm(0.24’’)
4 X M6
|
5L3 |
|
|
|
3L2 |
|
|
|
|
1L1 |
|
|
|
|
|
ST |
A1 |
A2 |
|
|
|
|||
|
L1 |
L2 |
L3 |
|
|
|
|
||
On |
Reayd |
|
T3 |
|
TOR |
T2 |
|
||
Run |
T1 |
|
|
|
U |
Star t / |
|
|
|
|
VDC |
|
||
|
Stop |
24 |
|
|
U |
|
A1 |
A2 |
|
ST |
|
|
||
|
Run |
Com |
TOR |
|
|
|
|
||
|
Run Cmo |
TOR |
||
|
|
|||
|
6T3 |
|
|
|
4T2 |
|
|
|
|
2T1 |
|
|
|
|
According to
UL 508 and CSA-C22.2 No. 14-05
Minimum Enclosure size 24*13*8 Inch. Two latching points min.
For use in Pollution degree 2 environment. Suitable for use on a circuit capable of delivering not more than 85000 symmetrical A, 600 V max when protected by (x) J class time delay fuses.
Model PSR60 |
PSR72 |
PSR85 |
PSR105 |
(x) = 110A |
125A |
150A |
200A |
Use fuse only. |
|
|
|
Device intended to be supplied by an external isolated power supply that complies with limited voltage/current circuit req.of UL508. The external isolated power supply voltage shall not be higher than 24V dc and shall be protected by an UL248 fuse rated max. 4A
<![endif]>>25mm(0.98” )
PSR60, 72, 85, 105 |
|
||
|
Start / |
|
|
|
Stop |
24 VDC |
|
|
ST |
A1(+) A2 |
|
|
Run |
Com TOR |
|
Insex 4mm |
4.5 Pozidriv N 1 |
|
|
8,0 Nm |
|
0.6 Nm |
|
71lb.in |
|
5lb.in |
|
AWG 6... AWG 2/0 |
AWG 18... AWG 12 |
||
20mm(0.79’’) |
|
|
|
|
2 X 0.75... 1.5 mm |
2 |
|
1 X 10... 95 mm2 |
2 |
||
2 X 6... 35 mm 2 |
1 X 0.75... 2.5 mm |
|
1SFC132040M0001
1/8
On |
Ready |
Supply |
Ready |
1L1 |
3L2 |
|
|
5L3 |
|||
Run |
|
TOR |
Run |
|
Full voltage |
|
|
|
|
|
|
U |
10 |
|
|
|
|
|
|
|
|
|
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
20 |
S |
Start ramp 1 - 20 s |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ST A1 |
A2 |
|
U |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
Stop ramp 0 - 20 s |
|
|
|
PSR60-600-81 |
||||
|
|
S |
|
|
|
||||||
|
20 |
|
|
|
On |
Ready |
L1 |
L2 |
L3 |
|
|
|
|
|
|
|
|
Run |
TOR |
|
|
|
|
|
55 |
|
|
|
U |
10 |
|
|
|
|
|
|
|
|
|
1 |
|
T1 |
T2 |
T3 |
|
||
|
|
|
|
|
20 |
|
|||||
40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Initial voltage |
40 - 70% |
|
U |
10 |
|
|
|
|
|
|
|
|
|
Start / |
|
|
|||||
|
|
|
|
0 |
|
Stop 24 VDC |
|
||||
|
|
% |
|
|
|
|
20 |
|
|
|
|
|
70 |
|
|
|
40 |
55 |
ST |
A1(+) A2 |
|
||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
70 |
Run Com TOR |
|||
|
|
|
|
|
|
|
|
||||
100% |
|
|
|
|
|
|
|
|
|
||
Initial voltage |
|
|
|
|
|
|
|
Run Com TOR |
|||
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
2T1 |
4T2 |
|
|
6T3 |
|
|
|
Start ramp |
Stop ramp |
|
|
|
|
|
|
||
Power Supply |
|
|
|
|
|
|
|
|
|
|
|
(A1 - A2) |
|
|
|
|
|
|
|
|
|
|
|
Main voltage |
|
|
|
|
|
|
|
|
|
|
|
(L1 - L3) |
|
|
|
|
|
|
|
|
|
|
|
Start/Stop signal |
|
|
|
|
|
|
|
|
|
||
(A1 - ST) |
|
|
|
|
|
|
|
|
|
|
|
Motor voltage |
|
|
|
|
|
|
|
|
|
|
|
(T1 - T3) |
|
|
|
|
|
|
|
|
|
|
|
Run output |
|
|
|
|
|
|
|
|
|
|
|
TOR output |
|
|
|
|
|
|
|
|
|
|
|
LED1 |
|
|
|
|
|
|
|
|
|
|
|
On/ Ready |
|
|
|
|
|
|
|
|
|
|
|
LED2 |
|
|
|
|
|
|
|
|
|
|
|
Run /TOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2/8 |
|
|
|
|
|
7/8 |