1c |
|
e |
||
|
|
|
e |
lin |
|
|
|
|
|
|
|
s |
th |
rs |
|
|
to |
||
|
s |
c |
|
|
ro |
|
ta |
|
|
c |
|
n |
|
|
A |
|
o |
|
|
1
CAL5-11 |
CA5-10 |
1. 16
Accessories
for A/AF/BC & AE contactors
Auxiliary contact blocks |
|
– Standard |
|
|
|
|
|
|
|
|
|
Positioning |
|
Maximum number |
|
Contact |
|
|
Catalog |
|
List |
|
|
|
of contact blocks |
|
Description |
|
|
|
number |
price |
|
||
|
|
|
|
|
|
|
|||||
|
|
4 blocks: |
A9 – A26 |
1 |
N.O. |
|
|
|
CA5-10 |
|
|
|
|
|
AE9 – AE30 |
|
|
|
|
||||
|
|
|
1 |
N.C. |
|
|
CA5-01 |
|
|
||
Front mounting |
|
BC9 – BC30 |
|
|
|
|
|||||
|
|
|
|
|
|
|
|
$ 15 |
|||
(single pole) |
|
5 blocks: |
A30, A40 |
1 |
N.O. Early make |
|
CC5-10 |
|
|||
|
|
6 blocks: |
A45 – A110 |
|
|
|
|||||
|
|
1 |
N.C. Late break |
|
|
CC5-01 |
|
|
|||
|
|
|
AE45 - AE110 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A9 – A26-40-00 |
4 |
N.O. |
|
|
|
CA5-40E |
|
|
|
|
|
3 |
N.O. & 1 N.C. |
|
|
CA5-31E |
|
|
||
|
|
|
A30 – A110 |
|
|
|
|
||||
Front mounting |
1 block: |
2 |
N.O. & 2 N.C. |
|
|
CA5-22E |
|
|
|||
AE9 – AE110 |
|
|
|
|
|||||||
(4 pole) |
|
|
4 |
N.C. |
|
|
CA5-04E |
|
|||
|
|
BC9 – BC30 |
|
|
|
||||||
|
|
|
2 |
N.O./2 N.C. |
1 |
|
|
CA5-11/11E |
|
||
|
|
|
|
|
|
|
|||||
|
|
|
|
3 |
N.O. & 1 N.C. |
|
|
CA5-31M |
|
30 |
|
|
|
|
A9 – A40-30-10 |
2 N.O. & 2 N.C. |
|
CA5-22M |
|
||||
|
|
1 block: |
|
|
|
||||||
|
|
BC9 – BC25-30-10 |
4 N.C. |
|
|
CA5-04M |
|
|
|||
|
|
|
|
|
|
|
|||||
|
|
|
|
2 |
N.O./2 N.C. |
1 |
|
|
CA5-11/11M |
|
|
|
|
2 blocks: |
A9 – A110 |
1 |
N.O. & 1 N.C. |
|
|
CAL5-11 |
|
|
|
Side mounting |
1 block: AE9 – AE110 |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
||||
(2 pole) |
|
2 blocks: |
A145 – AF750 |
1 N.O. & 1 N.C. (insi |
|
de L or R) |
CA |
L5-11 |
|
||
|
|
2 blocks: |
A145 – AF750 |
1 N.O. & 1 N.C. (outside, L or R) CAL5-11B |
|
|
|
|
Auxiliary contact blocks |
– Front mounting, switching low voltage and low current |
|
|
|
|
|||||
Positioning |
Maximum number |
Contact |
Degree of |
Catalog |
|
List |
|
|||
of contact blocks |
Description |
|
protection |
number |
|
price |
|
|||
|
|
|
|
|||||||
|
|
|
|
1 N.O. |
|
IP40 |
CE5 |
-10D0.1 |
|
|
|
4 blocks: |
A9 – A26 |
1 N.C. |
|
IP40 |
CE5-01D0.1 |
|
|
$ 38 |
|
Front mounting |
AE9 – AE30 |
1 N.O. |
IP40 |
CE5-10D2 |
|
|
||||
|
|
|
||||||||
(single pole) |
|
BC9 – BC30 |
1 N.C. |
|
IP40 |
CE5-01D2 |
|
|
|
|
|
5 blocks: |
A30, A40 |
1 N.O. |
|
IP67 |
CE5-10W0.1 |
|
|
||
|
6 blocks: |
A45 – A110 |
1 N.C. |
|
IP67 |
CE5-01W0.1 |
|
42 |
||
|
|
AE45 - AE110 |
1 N.O. |
|
IP67 |
CE5-10W2 |
|
|||
|
|
|
|
|
||||||
|
|
|
|
1 N.C. |
|
IP67 |
CE5-01W2 |
|
|
1 Includes 1 N.O. & 1 N.C. overlapping
Discount schedule ABA |
Low Voltage Products & Systems |
AC 1030.1 – 12/01
Accessories
for A/AE/AF contactors
A |
c |
|
|
|
|
|
|
|
|
ro |
s |
|
|
|
|
|
|
c |
|
|
|
|
|
|||
|
s |
|
|
|
|
|||
|
o |
|
|
|
th |
|
|
|
|
n |
|
|
|
e |
|
|
|
|
ta |
c |
|
lin |
|
|||
|
|
|
|
to |
|
e |
||
|
|
|
|
1rs |
|
ATK185
ZL75
WB75A-04
BA5-50
Terminal lug kits
|
Wire |
|
|
|
For |
|
|
Catalog |
|
List |
|
range |
|
contactor |
|
number |
|
price |
|
||
6 |
– 250 MCM |
A145 |
– |
A185 |
ATK185 |
|
|
|
$ 45 |
|
4 |
– 400 MCM |
A210 |
– |
A300 |
ATK300 |
|
|
|
68 |
|
(2) 4-500 MCM |
|
A210 |
– |
A300 |
ATK300/2 |
|
|
|
110 |
|
(2) 2/0 – 500 MCM |
AF400 |
– |
AF580 |
ATK580/2 |
|
|
|
150 |
||
(3) 2/0 – 500 MCM |
AF400 |
– |
AF750 |
ATK750/3 |
|
|
|
225 |
1
Contact kits
For contactors |
|
Catalog |
List |
|
number |
price |
|
|
|
||
3 Pole |
|
|
$ 113 |
A/AE/AF50 |
|
ZL50 |
|
A/AE/AF63 |
|
ZL63 |
135 |
A/AE/AF75 |
|
ZL75 |
158 |
A/AE/AF95 |
|
ZL95 |
225 |
A/AE/AF110 |
ZL110 |
255 |
|
A/AF145 |
ZL145 |
300 |
|
A/AF185 |
|
ZL185 |
420 |
A/AF210 |
ZL210 |
525 |
|
A/AF260 |
ZL260 |
855 |
|
A/AF300 |
ZL300 |
1020 |
|
AF400 |
|
ZL400 |
1716 |
AF460 |
|
ZL460 |
2434 |
AF580 |
|
ZL580 |
3795 |
AF750 |
|
ZL750 |
3960 |
4 Pole |
|
|
150 |
A/AE45 |
ZLT45 |
||
A/AE50 |
ZLT50 |
150 |
|
A/AE75 |
|
ZLT75 |
210 |
Mechanical latches
For contactors |
Catalog |
List |
|
number |
price |
||
|
A9 - A75 & AE45 -AE75 |
WB75A- |
|
$ 84 |
- Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the |
|
|
. |
Coil voltage selection chart — |
|
mechanical latches for A & AE contactors |
|||||||
|
|
|
|
|
|
|
|
|
|
|
50 Hz |
|
|
|
60 Hz |
Voltage |
|
||
|
|
|
|
code |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
24 |
|
|
24 |
– |
28 |
01 |
|
|
|
42 |
|
|
42 |
– |
48 |
02 |
|
|
|
48 |
|
|
48 |
– 55 |
03 |
|
|
|
110 |
|
110 |
– |
127 |
04 |
|
||
220 |
– |
230 |
220 |
– |
255 |
|
06 |
|
|
230 |
– |
240 |
230 |
– |
277 |
|
05 |
|
|
380 |
– |
415 |
380 |
– |
440 |
07 |
|
||
415 |
– |
440 |
440 |
– |
480 |
|
08 |
|
|
Range: |
|
|
|
|
|
|
|
|
|
WB75A for contactors A9 – A75, AC9 – AC30, AE45 – AE75 and control relays N and KC. |
Description: WB75A block: contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC) or manual unlatching.
Captive screw type connecting terminals, built-in cable clamps, M 3.5 (=, -) posidrive 1 screw with screwdriver guidance, delivered untightened and protected against accidental direct contact.
Operation: After closing, the contactor continues to be held in the closed position by the latching mechanisim should the supply voltage fail at the contact coil terminals.
Contactor opening can be controlled:
•Electrically by an impulse* (AC or DC) on the WB75A block coil. The coil is not designed to permanently energized.
•Manually by pressing the pushbutton on the front face of the WB75A block.
Mounting: WB75A is clipped onto the front face of the contactor.
Identification marker
Mounting |
Coil |
|
Catalog |
List |
|
on |
voltage |
|
number |
price |
|
A9 – A110 |
Pack of 50 |
BA5- |
50 |
|
$ 15 |
Low Voltage Products & Systems |
Discount schedule ABA |
1 .25 |
|
|
AC 1030.1 – 12/01 |
1c |
|
e |
||
|
|
|
e |
lin |
|
|
|
|
|
|
|
s |
th |
rs |
|
|
to |
||
|
s |
c |
|
|
ro |
|
ta |
|
|
c |
|
n |
|
|
A |
|
o |
|
|
1
ZA16-81
Accessories
for A/AE/AF contactors Coils & coil voltage codes
Coils |
— AC operated |
|
|
|
|
|
|
|
|
For contactors |
|
|
Catalog |
List |
|||
|
|
|
number |
price |
||||
|
|
|
|
|
|
|
||
|
A9 |
– |
A16 |
ZA16- |
|
$ 24 |
||
|
A26 |
– |
A40 |
ZA40- |
|
30 |
||
|
A45 |
– |
A75 |
ZA75- |
|
57 |
||
|
A95 |
– |
A110 |
ZA110- |
|
60 |
||
|
A145 |
– |
A185 |
ZA185- |
|
150 |
||
|
A210 |
– |
A300 |
ZA300- |
|
180 |
||
Coils |
— DC operated |
|
|
|
|
|
|
|
|
AE9 – |
AE16 |
ZAE16 |
- |
|
24 |
||
|
AE26 |
– |
AE40 |
ZAE40 |
- |
|
30 |
|
|
AE45 |
– |
AE75 |
ZAE75- |
|
57 |
||
|
AE95 |
– |
AE110 |
ZAE110- |
|
90 |
||
|
BC9 |
– |
BC30 |
KBC30G- |
|
36 |
||
Auxiliary including an insertion contact and a varistor for DC operated contactors |
|
|
|
|
||||
|
AE45 |
– |
AE75 |
CDL5-01 |
|
45 |
||
|
AE95 |
– |
AE110 |
CCL5-01 |
|
|||
|
|
|
||||||
Coils |
— AC/DC operated |
|
|
|
|
|
|
|
|
AF45 |
– |
AF75 |
ZAF75- |
|
120 |
||
|
AF95, AF110 |
ZAF110- |
|
165 |
||||
|
AF145 – AF185 |
ZAF185- |
|
200 |
||||
|
AF210 – AF300 |
ZAF300- |
|
240 |
||||
|
AF400, AF460 |
ZAF460- |
|
450 |
||||
|
AF580, AF750 |
ZAF750- |
|
525 |
||||
– Coil voltage suffix. Refer to Coil Voltage Selection charts below and substitute the desired coil voltage code for the |
|
|
. |
|
Coil voltage selection — AC operated for A9 – A300; UA26 – UA110
VAC (50Hz) |
VAC (60Hz) |
Voltage |
|
|||
Code |
|
|||||
|
|
|
|
|
|
|
|
|
24 |
|
24 |
81 |
|
|
|
26 |
|
28 |
16 |
|
|
|
28 |
|
32 |
17 |
|
|
|
42 |
|
42 |
82 |
|
|
|
48 |
|
48 |
83 |
|
|
|
60 |
|
60 |
73 |
|
|
|
100 |
100 – 110 |
74 |
2 |
|
|
|
110 |
110 – 120 |
84 |
|
|
110 |
– 115 |
115 – 127 |
89 |
3 |
||
|
|
120 |
|
140 |
29 |
|
125 |
– 127 |
150 |
30 |
|
||
|
|
175 |
|
208 |
34 |
|
|
|
190 |
|
220 |
36 |
|
|
|
200 |
200 – 220 |
75 |
2 |
|
220 |
– 230 |
230 – |
240 |
80 |
|
|
230 |
– |
240 |
240 – |
260 |
88 |
|
230 |
– |
240 |
277 |
42 |
|
|
230/400 |
|
— |
62 |
1 |
||
|
|
— |
230/400 |
63 |
1 |
|
380 – 400 |
400 – 415 |
85 |
|
|||
400 – 415 |
415 – 440 |
86 |
|
|||
|
|
— |
|
480 |
51 |
|
|
|
440 |
|
500 |
53 |
|
|
|
500 |
|
600 |
55 |
|
|
|
550 |
|
— |
56 |
|
660 |
– 690 |
|
— |
58 |
|
|
|
|
|
|
|
|
|
Coil voltage selection — DC operated for AE contactors
|
Voltage code |
VDC |
AE |
|
contactors |
12 |
80 |
24 |
81 |
42 |
82 |
48 |
83 |
50 |
21 |
60 |
84 |
75 |
85 |
110 |
86 |
125 |
87 |
220 |
88 |
240 |
89 |
250 |
38 |
Coil voltage selection — DC operated for BC contactors
|
Voltage code |
VDC |
AE |
|
contactors |
12 |
07 |
24 |
01 |
42 |
02 |
48 |
16 |
50 |
17 |
60 |
03 |
75 |
22 |
110 |
04 |
125 |
27 |
220 |
05 |
240 |
33 |
250 |
34 |
|
|
Coil voltage selection — |
|
|
|
AC/DC operated for AF50 – AF750 |
|
||
|
|
VAC & VDC |
|
|
Suffix |
|
|||
|
|
40-60 Hz |
|
|
Code |
|
|||
|
24 |
– |
60 VDC |
|
68 |
4 |
|||
|
20 |
|
– |
60 |
VDC |
|
72 |
5 |
|
|
48 |
|
– |
130 VAC/VDC |
|
69 |
|
||
1 Only for A9 – A16. |
100 |
– |
250 |
VAC/VDC |
|
70 |
|
||
200 |
– |
500 |
VAC/VDC |
|
71 |
|
|||
2 Not for A145 – A300 |
|
|
|
|
|
|
|
|
|
3 A145 – A300 at 60 Hz, 115V only. |
|
|
|
|
|
|
|
|
|
4 AF400 – AF750. |
|
|
|
|
|
|
|
|
|
5 AF145 – AF300. |
|
|
|
|
|
|
|
|
|
1. 26 |
Discount schedule ABA |
|
|
|
|
Low Voltage Products & Systems |
|
AC 1030.1 – 12/01