General information Product overview
Description
AF09 – AF750 and AFN00 - AFN4
•Maximum UL/CSA horsepower ratings
•Available with non-reversing, reversing, two speed one winding and two speed two winding
•Available in non-combination and combination
•Available in UL type 1,3R,12, 4, and 4X stainless steel enclosures
•Available with non-fusible or fusible disconnect switches and thermal magnetic circuit breaker
•Compact space saving design
•Standard auxiliary contact configurations: AF09 – AF750 (AFN00-AFN4)
1 N.O. & 1 N.C.
•Double break contact design
•Lowest possible contact bounce
•Operates over an extended voltage range of 85% to 110% of rated control voltage
Overload relay protection
Starters, sizes AF09 – AF300 (AFN00-AFN4), have Class 10 adjustable ther - mal bimetallic overload relay protection as standard.
Sizes AF400 – AF750, have selectable Class 10, 20, 30 adjustable electronic overload relay protection as standard.
Optional electronic overload relay protection is available for all starter sizes.
Field modification kits
Offers a wide variety of pilot device kits for non-reversing, reversing, two speed one winding and two speed two winding starters.
Control circuit transformer kits are also available with the following voltages:
Control Voltage |
200-208 |
230-240 |
460-480 |
575-600 |
|
|
|
|
|
120V AC @ 50/60 Hz |
A |
B |
C |
D |
24V AC @ 50/60 Hz |
E |
F |
G |
H |
|
|
|
|
|
The field kits are pre-wired, ready to operate, making installation easy and reliable
2 | IEC & NEMA Enclosed starters
General information
Features and benefits
7
56
1
8
Features and benefits
1.Durable protective finish (carbon steel enclosures)
-Industry exclusive electrophoretic dip coat prime
-Power coated surface for added protection
2.Flange trough collar opening
-Channels liquids and dust away from enclosure gasket and enclosure interior
3.Seamless foamed-in-place gasket
-Provide secure seal against contaminates
-Ensures a dust tight and water tight seal
4.Pre-drilled mounting plate
-Easy mounting for control circuit transformer kit
2
3 4
5.Rugged and compact 22 mm pilot devices
-Meets UL/NEMA Type 1, 3R. 4, 4X. 12, 13
6.Convenient hole plugs for pilot device control
-Allows for quick installation of pilot device kit
7.Disconnect handle accepts 3 -3/8” padlocks in off position for safe maintenance
8.Quarter turn enclosure latches
-Allows for quick entry and proper sealing of enclosure
IEC & NEMA Enclosed starters | 3
Catalog number explanation
Non-combination starter
AF26 1 S N 1 - 2 H A
Contactor size
AF26 |
AF210 |
AFN00 |
AF30 |
AF260 |
AFN0 |
AF50 |
AF300 |
AFN1 |
AF63 |
AF400 |
AFN2 |
AF75 |
AF460 |
AFN3 |
AF110 |
AF580 |
AFN4 |
AF145 |
AF750 |
|
AF185 |
|
|
Starter type
1 - Non reversing
2 - Reversing
3 - 2 Speed, 1 winding
4 - 2 Speed, 2 winding
Single phase
S - Single phase (insert only for single phase)
Disconnect type
Blank - Non-combination (starter only)
N - Non-fusible disconnect
Enclosure type
2 - NEMA/UL Type 1, 3R, 4, 12
X - NEMA/UL Type 4X (Stainless steel)
Coil voltage CCT
Coil voltage selection
AC Volts, 40-60 Hz
24 AC |
|
|
100 - 250 AC |
|
|
250 - 500 AC |
|||
|
|
|
|
|
|
|
|
|
|
1 |
|
|
2 |
|
|
3 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
CCT Selection |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
||
Control Voltage |
200-208 |
|
230-240 |
460-480 |
|
575-600 |
|
||
|
|
|
|
|
|
|
|
|
|
120V AC @ 50/60 Hz |
|
A |
|
B |
|
C |
|
D |
|
24V AC @ 50/60 Hz |
|
E |
|
F |
|
G |
|
H |
|
|
|
|
|
|
|
|
|
|
|
Option 1
See factory installed modifications on pages 29 & 30
Overload selection
See overload relay selection on pages 34 - 37
IEC & NEMA Enclosed starters | 5