GS-R400 Family
20W TO 140W STEP-DOWN SWITCHING REGULATOR FAMILY
FEATURES
MTBF in excess of 200,000 hours
4A max output current
46V max input voltage
4V max drop-out voltage
Soft start
Remote logic inhibit/enable
Remote output voltage sense
Non-latching overload and short circuit protection
Crow-bar output overvoltage protection
DESCRIPTION
The GS-R400 series is a versatile family of high current, high voltage step-down switching voltage regulators.
The integral heatsink allows a large power handling capability and it provides also an effective shielding to minimize EMI.
SELECTION CHART
Type |
|
Output |
|
Input |
|
Output |
Regulation |
Efficiency |
|
|
|
|||
|
|
|
|
|
|
|
|
|||||||
Ordering |
Voltage |
|
Voltage |
|
Ripple |
Line |
Load |
|
|
Notes |
||||
Number |
|
(V) |
|
(V) |
|
(mVpp) |
(%) |
|
|
|
|
|||
|
|
|
(mV/V) |
(mV/A) |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R405 |
|
5.1 ± 2% |
|
9 to 46 |
|
25 |
2 |
20 |
70 |
|
Fixed output voltage |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R412 |
|
12.0 ± 4% |
|
16 to 46 |
|
50 |
5 |
40 |
80 |
|
|
" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R415 |
|
15.0 ± 4% |
|
19 to 46 |
|
65 |
5 |
60 |
85 |
|
|
" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R424 |
|
24.0 ± 4% |
|
28 to 46 |
|
100 |
6 |
90 |
90 |
|
|
" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R405S |
|
5.1 ± 2% |
|
9 to 46 |
|
25 |
2 |
20 |
70 |
|
Reset output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R400V |
|
5.1 to 40 |
|
Vo+4 to 46 |
|
25 to 100 |
6 |
20 to 90 |
70 to 90 |
Progr. output voltage |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R400VB |
5.1 to 40 |
|
Vo+4 to 46 |
|
25 to 100 |
6 |
20 to 90 |
70 to 90 |
Progr. output voltage and |
|||||
|
|
current. Frequency synchr. |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Note: The line regulation is measured at Iout=1A |
|
|
|
|
|
|
|
|
||||||
The load regulation is measured at Vin=Vo+8V and Iout=1 to 3A |
|
|
|
|
|
|
||||||||
For VO ³ 36V and Io = 4A an external heatsink or forced ventilation are required. |
|
|
|
|
|
|||||||||
ABSOLUTE MAXIMUM RATINGS |
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Symbol |
|
|
|
|
|
|
Parameter |
|
|
|
|
Value |
|
Unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Vi |
|
DC Input Voltage |
|
|
|
|
|
|
|
48 |
|
V |
||
Irt* |
|
Reset Output Sink Current |
|
|
|
|
|
20 |
|
mA |
||||
|
|
|
|
|
|
|
|
|
|
|
||||
Tstg |
|
Storage Temperature Range |
|
|
|
|
|
– 40 to +105 |
|
°C |
||||
Tcop |
|
Operating Case Temperature Range |
|
|
|
|
– 20 to +85 |
|
°C |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* GS-R405S only |
|
|
|
|
|
|
|
|
|
|
|
|
||
June 1994 |
|
|
|
|
|
|
|
|
|
|
|
1/5 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GS-R400 FAMILY
CONNECTION DIAGRAM AND MECHANICAL DATA
Pin 2 GS-R405S only
Pin 5,6,7 GS-R400VB only
Pin 12 GS-R400V/VB only
Dimensions in mm Bottom view
PIN DESCRIPTION
Pin |
Function |
|
Description |
|
|
|
|
|
|
||
1 |
Inhibit |
The module is disabled by a high logic level applied to this pin. |
|
||
|
|
|
|
||
2 |
Reset |
Reset output (GS-R405S only). |
|
||
|
|
|
|
||
3 |
+ Input |
DC input voltage. Recommended maximum voltage is 46V. |
|
||
|
|
|
|
||
4 |
Input GND |
Return for input voltage source. |
|
||
|
|
|
|
||
5 |
Oscillator |
100kHz oscillator output. To be connected to Sync (pin 6) input if the unit is a master and |
|
||
left open if it is a slave (GS-R400VB only). See fig. 5. |
|
||||
|
|
|
|||
|
|
|
|
||
6 |
Sync |
Synchronization input. To be connected to the Oscillator output (pin 5) of the master (GS- |
|
||
|
|
R400VB only). See fig. 5. |
|
||
|
|
|
|
||
7 |
Current limiting |
A resistor (³ 2.2kW) connected from this pin to pin 9 sets the current limiting level |
|
||
|
|
(GS-R400VB only). |
|
||
|
|
|
|
||
8 |
Output GND |
Return for output current path. |
|
||
|
|
Internally connected to pin 4. |
|
||
|
|
|
|
||
9 |
– Sense |
Senses the remote load return. Must be tied to pin 8 when the remote sensing feature is |
|
||
|
|
not used. See fig. 1. |
|
||
|
|
|
|
||
10 |
+ Sense |
Senses the remote load high side. Must be tied to pin 11 when the remote load sensing |
|
||
|
|
feature is not used. See fig. 1. |
|
||
|
|
|
|
||
11 |
+ Output |
Regulated DC output voltage. |
|
||
|
|
|
|
||
12 |
Program |
A resistor (£ 18kW) connected between this pin and pin 10 sets the output voltage |
|
||
|
|
(GS-R400V and GS-R400VB only). |
|
||
|
|
|
|
|
|
2/5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|