Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.
Split Type Room Air Conditioner
OPERATING INSTRUCTIONS
Indoor Unit Model: |
Outdoor Unit Model: |
CS-SA9CKP |
CU-SA9CKP5 |
CS-SA12CKP |
CU-SA12CKP5 |
ENGLISH ...................... |
P. |
1 |
—— P. 8 |
PORTUGUÊS ............... |
P. |
9 —— P. 16 |
|
DEUTSCH ..................... |
P. 17 |
—— P. 24 |
|
FRANÇAIS .................... |
P. 25 —— P. 32 |
||
NEDERLAND ................ |
P. 33 |
—— P. 40 |
|
ITALIANO ..................... |
P. 41 |
—— P. 48 |
|
GREEK ......................... |
P. 49 |
—— P. 56 |
|
ESPAÑOL ..................... |
P. 57 —— P. 64 |
||
RUSSIAN ...................... |
P. 65 |
—— P. 73 |
MATSUSHITA AIR-CONDITIONING CORP.
XIECUN, ZHONGCUN TOWN, PANYU DISTRICT.
GUANGZHOU CITY, GUANGDONG PROVINCE, CHINA
F563553
F563553/01-08/EN |
1 |
5/6/02, 10:34 am |
Thank you very much for purchasing Panasonic Split Type Room Air Conditioner.
CONTENTS
3 Safety Precautions ...................................... |
1~2 |
■Installation Precautions
■Operation Precautions
3 Name of Each Part ....................................... |
2~3 |
|
■ |
Indoor Unit |
|
■ |
Outdoor Unit |
|
■ |
Accessories |
|
3 Basic Operation ........................................... |
4~5 |
|
3 Setting the Timer ............................................... |
5 |
|
3 Care and Maintenance ................................ |
5~6 |
■Cleaning the lndoor Unit and Remote Control
■Cleaning the Air Filter
■Cleaning the Front Panel
■Pre-season lnspection
■When the Air Conditioner is Not Used for an Extended Period of Time
■Recommended lnspection
3 Helpful Information ........................................... |
6 |
3 Energy Saving and Operation Hints ............... |
6 |
3 Trouble Shooting .............................................. |
7 |
■Normal Operation
■Abnormal Operation
■Call the Dealer lmmediately
3 Evaluation of the Performance ........................ |
8 |
3 Safety Notes ...................................................... |
8 |
1
SAFETY PRECAUTIONS
Before operating, please read the following “Safety Precautions” carefully.
●To prevent personal injury, injury to others and property damage, the following instructions must be followed.
●Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow:
Warning
This sign warns of death or serious injury.
Caution
This sign warns of injury or damage to property.
●The instructions to be followed are classified by the following symbols:
This symbol (with a white background) denotes an action that is PROHIBITED.
These symbols (with a black background) denote actions that are COMPULSORY.
■ Installation Precautions
Warning
Do not install, relocate or repair the unit by yourself.
This air conditioner must be earthed.
Improper grounding could cause electric
shock or fire.
Caution
Ensure that the following installation precautions have been applied before installing the air conditioner.
■ The power socket must be earthed.
Improper grounding may cause current
leakage.
■Ensure that the drainage pipings are properly connected.
Water leakage could happen due to improper connection thus cause inconvenience.
■Do not install the unit in a potentially explosive atmosphere. Otherwise, fire or other hazard may occur.
F563553/01-08/EN |
2 |
5/6/02, 10:34 am |
■ Operation Precautions
Warning |
3 |
This sign warns of death or serious injury.
●Do not share outlet.
●Do not insert plug to operate the unit. Do not pull out plug to stop the unit.
●Do not operate with wet hands.
●Do not damage or modify the power cord.
●Do not insert finger or other objects into the indoor or outdoor units.
●Do not expose directly to cold air for a long period.
●Plug in properly.
● Use specified power cord.
● If abnormal condition (burnt smell, etc.) occurs, switch off and unplug the power supply.
Caution
This sign warns of injury.
●Do not pull the cord to disconnect the plug.
●Do not wash the unit with water.
●Do not use for other purposes such as preservation.
●Do not use any combustible equipment at airflow direction.
●Do not sit or place anything on the outdoor unit.
●Switch off the power supply before cleaning.
●Ventilate the room regularly.
● Pay attention as to whether the installation rack is damaged after long period of usage.
● Switch off the power supply if the unit is not used for a long period.
NAME OF EACH PART
■ Indoor Unit
2
1
3
4 |
5 |
|
6 |
7 |
|
|
8 |
9 |
1 Front Panel
2 Air Intake Vent
3 Power Supply Cord
4 Air Outlet Vent
5 Vertical Airflow Direction Louver
6Horizontal Airflow Direction Louver (manually adjusted)
7Auto Operation Button
(when the front panel is opened)
8 Air Filters
9Indicator Panel
●POWER : Green (Operation)
●T I M E R : Orange
Auto Operation / Test Run Operation
If the remote control not available, press the button for Auto Operation. Keeping this button depressed for more than 5 seconds to start the Test Run Operation (cooling only), for the purpose of installation or repairment only.
■ Outdoor Unit |
|
ENGLISH |
|
|
|
1 |
2 |
|
|
|
3 |
|
|
4 |
|
|
5 |
6 |
|
|
1 Air Intake Vents |
|
2 |
1 |
|
|
2 Ground Terminal |
|
3 |
(Inside cover) |
|
|
3 Piping |
|
|
4 Connecting Cable |
|
4 |
|
|
|
5 Drain Hose |
|
|
6 Air Outlet Vent |
6 |
5 |
|
|
■Accessories
● Remote Control
● Two dry-cell batteries.