Panasonic CU-A95KR, CUA75KR, CSA75KR, CU-A125KR, CS-A95KR User Manual

...
4 (1)
Panasonic CU-A95KR, CUA75KR, CSA75KR, CU-A125KR, CS-A95KR User Manual

Room Air Conditioner

OPERATING INSTRUCTIONS

Indoor

Outdoor

Model CS-A75KR Model

CU-A75KR

CS-A95KR

CU-A95KR

CS-A125KR CU-A125KR

Before using your air-conditioner, please ENGLISH ................................ P. 1 – P. 28 read this operating instructions carefully

and keep it for future reference.

F563254

CONTENTS

1Before use

:

FEATURES ......................................................................

3

:

SAFETY PRECAUTIONS ..........................................

4 – 6

 

Installation Precautions

 

 

Operation Precautions

 

: NAME OF EACH PART ...........................................

7 – 10

 

Indoor Unit

 

 

When the front panel is opened

 

 

Outdoor Unit

 

 

Accessories

 

 

Remote Control

 

 

When the remote control is opened

 

 

How to use the remote control

 

 

When the back cover is opened

 

:

PREPARATION BEFORE OPERATION ...............

11 – 12

 

Indoor unit

 

 

Remote Control

 

 

Inserting batteries

 

 

Setting the clock

 

 

About the batteries

 

2How to use

: HOW TO OPERATE ...............................................

13 – 14

Automatic • Heating • Cooling • Soft Dry

Operation details

Adjusting Airflow Direction and Fan Speed

Operation details

:

SETTING THE TIMER ............................................

15 – 16

 

Recommended Setting of Timer

 

:

CONVENIENCE OPERATION ...............................

17 – 18

Sleep Mode

Operation details

Economy or Powerful Mode Operation details

1

 

 

 

 

3 If necessary

:

.................................CARE AND MAINTENANCE

19 – 22

 

Cleaning the Indoor Unit and Remote Control

 

Cleaning the Air Filter

Cleaning the Front Panel

Removing the front panel

Fixing the front panel

Cleaning the front panel

Replacing the Air Purifying Filters

Removing the air purifying filters

Reinstalling the air purifying filters

Pre-season Inspection

When the Air Conditioner is Not Used for an Extended Period of Time

Recommended Inspection

: TROUBLESHOOTING ...........................................

23 – 24

Normal Operation

Abnormal Operation

Call the Dealer Immediately

:

HELPFUL INFORMATIONS ..........................................

25

:

ENERGY SAVING AND OPERATION HINTS...............

26

ENGLISH

2

FEATURES

SELF-ILLUMINATING BUTTON

For your convenience to operate in the dark.

(Refer page 9)

AUTOMATIC OPERATION

Sense intake air temperature every hour to select the optimum mode.

(Refer page 13)

SLEEP MODE

Prevent the room from getting too hot or too cold while you are sleeping.

(Refer page 17)

ECONOMY MODE

To reduce electrical power consumption.

(Refer page 18)

POWERFUL MODE

Reaches the desired room temperature quickly.

(Refer page 18)

REMOVABLE FRONT PANEL

For quick and easy cleaning (washable).

(Refer page 20)

CATECHIN AIR PURIFYING FILTER.

Filter that can trap dust, tobacco smoke and tiny particles in the room. It can also prevent the growth of bacteria and viruses trapped in this filter.

(Refer page 21)

DEODORIZING FILTER

Used to remove unpleasant odours and deodorize the air in the room.

(Refer page 21)

AUTO RESTART CONTROL

Automatically restart the unit after power failure.

(Refer page 25)

Thank you for purchasing a Panasonic Room Air Conditioner.

Note:

Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.

3

SAFETY PRECAUTIONS

Before operating, please read the following “Safety Precautions” carefully.

To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follows:

ENGLISH

! Warning

This sign warns of death or serious injury.

! Caution

This sign warns of damage to property.

■ The instructions to be followed are classified by the following symbols:

This symbol (with a white background) denotes an action that is PROHIBITED.

OFF

These symbols (with a black background) denote actions that are COMPULSORY.

Installation Precautions

!Warning

Do not install, remove and reinstall the unit yourself.

Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work.

!Caution

This room air conditioner must be earthed.

Improper grounding could cause electric shock.

Do not install the unit in a place where there may be explosive gas leaks.

Gas leaks near the unit could cause fires.

Ensure that the drainage piping is connected properly.

Otherwise, water will leak out.

4

Operation Precautions

! Warning

This sign warns of death or serious injury.

Do not share outlet.

Do not repair by yourself.

Do not insert plug to operate the unit. Do not pull out plug to stop the unit.

Plug in properly.

Do not operate with wet hands.

Use specified power cord.

Do not damage or modify the power cord.

OFF

If abnormal condition (burnt smell, etc) occurs, switch off and unplug the power supply.

Do not insert finger or other objects into the indoor or outdoor units.

Do not exposed directly to cool air for a long period.

5

OFF

Switch off the power supply if the unit is not used for a long period.

ENGLISH

! Caution

This sign warns of injury.

Do not pull the cord to disconnect the plug.

Switch off the power supply before cleaning it.

Do not wash the unit with water.

Do not use for other purpose such as preservation or etc.

Do not use any combustible equipment at airflow direction.

Ventilate the room regularly.

Do not sit or place anything on the outdoor unit.

Pay attention as to whether the installation rack is damaged due to long period of usage.

6

NAME OF EACH PART

Indoor Unit

Front Panel

Air Intake Vents

Power Supply Cord

POWER SLEEP

TIMER

ECONOMY POWERFUL

Panel Opener

 

 

 

 

Signal Receptor

 

Horizontal Airflow Direction

Air Outlet Vents

 

 

Louver (Manually adjusted)

 

 

Operation Indicators

 

 

Vertical Airflow Direction

 

 

● POWER

: Green

 

 

Louver

 

 

● SLEEP

: Orange

 

 

 

 

 

 

 

 

● TIMER

: Orange

 

 

 

 

Economy/Powerful Indicators

 

 

 

Economy - Green

 

POWER SLEEP TIMER

 

 

Powerful - Orange

 

 

 

 

 

 

 

 

 

 

ECONOMY

 

 

 

 

 

POWERFUL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the front panel is opened

Front Panel

Auto Operation Button

Air Purifying Filter

Air Filters

POWER SLEEP TIMER

ECONOMY

POWERFUL

Tab for Front Panel

7

Outdoor Unit

Air Intake Vents

(Rear)

Connecting cable

(Side)

Drain Hose

Piping

Air Outlet Vents

Ground Terminal (Inside Cover)

Accessories

COOL

AUTO

TEMP

POWERFUL

OFF/ON

 

Remote Control

Remote Control Holder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

Two RO3 (AAA) dry-cell batteries

Air Purifying Filters

or equivalent

(Catechin Air Purifying Filters and

 

Deodorizing Filters)

8

Loading...
+ 21 hidden pages