Panasonic CU-C9BKP6, CU-C12BKP6, CS-C9BKP, CS-C12BKP User Manual

0 (0)

Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.

®

Room Air Conditioner

OPERATING INSTRUCTIONS

Before using your air-conditioner,

COOLING MODEL :-

 

Indoor

Outdoor

CS-C9BKP

CU-C9BKP6

CS-C12BKP

CU-C12BKP6

ENGLISH .......................

P.

1 –

P.

11

ESPAÑOL ......................

P.

12 –

P.

22

For assistance, please call; 1-800-211-PANA (7262) or send e-mail to: consumerproducts@panasonic.com or refer to www.panasonic.com

F563366

Thank you for purchasing our Panasonic Room Air Conditioner.

CONTENTS

 

:Features .....................................................

1

:Safety Precautions ....................................

2

■ Installation Precautions

 

■ Operation Precautions

 

:Name of Each Part ................................

3~4

■ Indoor Unit

 

■ Outdoor Unit

 

■ Accessories

 

■ Remote Control

 

:Preparation Before Operation ..................

5

■ Indoor Unit

 

■ Remote Control

 

:How to Operate ......................................

5~6

:Setting the Timer .......................................

7

:Convenience Operation ............................

7

■ Sleep Mode Operation

 

■ Economy Mode Operation

 

■ Powerful Mode Operation

 

:Care and Maintenance ..............................

8

Cleaning the Indoor Unit and Remote Control

Cleaning the Air Filter

Cleaning the Front Panel

Air Purifying Filters

Pre-season Inspection

When the Air Conditioner is Not Used for an Extended Period of Time

Recommended Inspection

:Helpful Information ...................................

9

:Energy Saving and Operation Hints ........

9

:Troubleshooting ......................................

10

■ Normal Operation

 

■ Abnormal Operation

 

■ Call the Dealer Immediately

 

:Product Specification and Reference ......

11

Note:

Before using your air conditioner, please read this operating instructions carefully and keep it for future reference.

FEATURES

Self-illuminating Button

For your convenience to operate in the dark.

(Refer page 4)

Automatic Operation

Sense indoor temperature to select the optimum mode.

(Refer page 5)

Sleep Mode

Prevent the room from getting too hot or too cold while you are sleeping.

(Refer page 7)

Economy Mode

To reduce electrical power consumption.

(Refer page 7)

Powerful Mode

Reaches the desired room temperature quickly.

(Refer page 7)

Removable Front Panel

For quick and easy cleaning. (washable)

(Refer page 8)

Catechin Air Purifying Filter

Filter that can trap dust, tobacco smoke and tiny particles in the room. It can also prevent growth of bacteria and viruses trapped in this filter.

(Refer page 8)

Solar Refreshing Deodorizing Filter

Used to remove unpleasant odour and deodorize the air in the room.

(Refer page 8)

Auto Restart Control

Restart the unit automatically after power failure.

(Refer page 9)

Blue Coated Condenser At Outdoor Unit

This is the most advanced anti-rust coating.

!Warning

1)Operate your air conditioner from a stable 208/230 volts AC supply.

2)Plug into a separate 15 amps grounded outlet only.

3)Use of extension cords.

Avoid using extension cords. If there are no alternatives, ensure that the cord is a UL listed 3-wire grounding type, rated 250 volt with a minimum current-carrying rating of 15 amps, number 16 or a heavier wire.

4)Use a 15 amps time delay fuse or a circuit breaker.

5)Do not switch off by unplugging the power plug while it is operating. Turn off the air conditioner by using remote control, before unplugging.

6)Remove power plug or disconnect from the main before servicing this appliance.

7)Do not repair by yourself.

In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair.

8)Turn off the power (Isolation from main power supply). Pull off the power plug from the receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the equipment from the main power supply in case of an emergency.

!Caution

DISCONNECT THE MAIN PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE, WHERE SUPPLY CONNECTION IS VIA MAIN PLUG.

POWER SUPPLY

Time Delay Fuse:

Line Cord Plug:

15 Amps

 

Rated Volts:

Socket Type:

208/230 V

 

1

SAFETY PRECAUTIONS

Before operating, please read the following “Safety Precautions” carefully.

To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow:

! Warning

This sign warns of death or serious injury.

! Caution

This sign warns of damage to property.

The instructions to be followed are classified by the following symbols:

This symbol (with a white background) denotes an action that is PROHIBITED.

OFF

These symbols (with a black background) denote actions that are COMPULSORY.

Installation Precautions

!Warning

Do not install, remove and reinstall the unit by yourself.

Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work.

!Caution

This room air conditioner must be

earthed.

Improper grounding could cause electric shock.

Ensure that the drainage piping is connected properly.

Otherwise, water will leak out.

Do not install the unit in a potentially explosive atmosphere.

Gas leak near the unit could cause fire.

Operation Precautions

! Warning

This sign warns of death or serious injury.

● Do not share outlet.

● Do not insert plug to operate the unit. Do not pull out plug to stop the unit.

● Do not operate with wet hands.

● Do not damage or modify the power cord. ● Do not insert finger or other objects into the

indoor or outdoor units.

● Do not expose directly to cold air for a long period.

● Plug in properly.

● Use specified power cord.

OFF

● If abnormal condition (burnt smell, etc.) occurs, switch off and unplug the power supply.

! Caution

This sign warns of injury.

● Do not pull the cord to disconnect the plug. ● Do not wash the unit with water.

● Do not use for other purposes such as preservation.

● Do not use any combustible equipment at airflow direction.

● Do not sit or place anything on the outdoor unit.

● Switch off the power supply before cleaning. ● Ventilate the room regularly.

● Pay attention as to whether the installation rack is damaged after long period of usage.

OFF ● Switch off the power supply if the unit is not

used for a long period.

ENGLISH

2

Panasonic CU-C9BKP6, CU-C12BKP6, CS-C9BKP, CS-C12BKP User Manual

NAME OF EACH PART

Indoor Unit

Indoor Unit

 

 

(when the front panel is opened)

1

2

 

 

1

3

 

3

 

 

2

 

7 6 5 4

1 Front Panel

2 Air Intake Vent

3 Power Supply Cord

4 Air Outlet Vent

5 Vertical Airflow Direction Louver

6 Horizontal Airflow Direction Louver

(manually adjusted)

7 Indicator Panel

1

2 3

456

1 Front Panel

2 Air Filters

3 Air Purifying Filter

Outdoor Unit

1

2

6

ECONOMY POWERFUL POWER SLEEP TIMERI

1 Auto Operation Button

 

 

1 Air Intake Vents

(when the front panel is opened)

 

2 Economy Mode Indicator

GREEN

2 Ground Terminal

(Inside cover)

 

 

 

3 Powerful Mode Indicator

ORANGE

3 Piping

 

 

 

4 Power Indicator

GREEN

4 Connecting Cable

 

 

 

5 Sleep Mode Indicator

ORANGE

5 Drain Hose

 

 

 

6 Timer Mode Indicator

ORANGE

6 Air Outlet Vents

 

 

 

Accessories

Remote Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UTT

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

COOLA L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

OO

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

F

UTTO

DRR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANN

 

 

 

 

 

 

 

 

 

POWERFUL

 

TEMP

F AUTT

 

 

 

 

 

 

 

 

 

 

 

 

 

AN O

 

 

 

 

 

 

 

 

 

 

 

MO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

DE

 

 

 

 

OFF/ON

 

 

 

 

 

 

 

tep

 

 

AIR

WIN G ECONOMY

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

SLE

EP

 

 

 

 

 

 

 

OFF

 

 

 

2

 

 

FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED

 

 

 

 

 

 

C HE

CK

 

 

TIM

 

 

 

SET

3

 

 

 

 

 

 

 

 

 

 

ER

 

 

 

 

 

 

 

 

 

 

 

 

RE

SET

 

 

 

 

CA

 

 

 

 

 

 

 

 

 

 

 

C

LOC K

 

 

 

NC EL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BA

TTE

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY

 

 

 

 

 

 

 

 

 

 

Remote Control Holder

Two RO3 (AAA) dry-cell batteries or equivalent

3

Air Purifying Filter

4

5

(Catechin Air Purifying Filter)

(Solar Refreshing Deodorizing Filter)

3

NAME OF EACH PART

Remote Control

1

 

 

2

AUTO

COOL DRY FAN

 

 

 

AUTO

 

F

ON

 

OFF

AUTO

FAN

 

 

 

TEMP

 

 

3

POWERFUL

 

OFF/ON

 

 

 

!

4

 

 

 

 

 

 

 

5

MODE

ECONOMY

SLEEP

#

6

 

AIR SWING

 

 

 

 

$

 

AUTO

MANUAL

FAN SPEED

7

$

1

2

3

8

%

ON

 

SET

 

 

 

9

OFF

 

CANCEL

^

 

 

 

 

 

TIMER

 

&

0

 

 

 

*

CHECK RESET CLOCK

(

Remote Control Signal.

Make sure it is not obstructed.

Maximum distance : 10 m (32.8 ft.).

Signal received sound.

One short beep or one long beep.

Notes for Remote Control.

Do not throw or drop.

Do not get it wet.

Certain type of fluorescent lamps may affect signal reception. Consult your dealer.

1 Signal Transmitter

2 Operation Display

3 Powerful Mode Operation Button

4 Room Temperature Setting Button

(self-illuminating button)

5 Operation Mode Selection Button

6 Economy Mode Operation Button

7 Auto Airflow Direction Button

8ON-Timer Button

9OFF-Timer Button

0 Reset Point

(Press with fine-tipped object to clear the memory)

!OFF/ON Button (self-illuminating button)

@ Sleep Mode Operation Button

# Fan Speed Selection Button

$ Manual Airflow Direction Selection Button

% Timer Set Button

^ Timer Cancellation Button

& Time-Setting Button

* Clock Button

( Remote Control Cover

How to Insert the Batteries

2

 

 

 

 

 

 

PO

W

 

 

 

 

 

 

 

 

 

 

ERFUL

 

 

 

 

 

 

MODE

 

 

 

 

 

 

 

 

AUTO

AIR

SWING ECONOMY

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

OFF

ON

 

 

MANUAL

 

 

 

SL

 

 

 

 

2

 

FAN

 

 

 

 

 

 

 

 

 

 

 

 

CHECK

TIMER

 

SET

3

 

SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

 

 

 

 

 

 

 

 

 

CANCEL

 

 

 

 

 

 

CLOCK

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

1

 

5V

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

5V

 

 

 

 

 

 

 

 

 

1

1 Slide down the remote control cover completely

2 Insert the batteries

Be sure the direction is correct

12.00 at display - flashing

Set the current time (CLOCK) immediately to prevent battery exhaustion.

About the batteries

Can be used for approximately one year.

Observe the following when replacing the batteries

Replace with new batteries of the same type.

Do not use rechargeable batteries (Ni-Cd).

Remove the batteries if the unit is not going to be used for a long period.

ENGLISH

4

PREPARATION BEFORE OPERATION

Indoor Unit

2

1

6

3

54

1Connect the power supply cord to an independent power supply

2Open the front panel

3Remove the air filters

4Fit the air purifying filters in place

5Insert the air filters

6Close the front panel

Remote Control

– To set the current time

AIR SWING

AUTO MANUAL FAN SPEED

1

2

3

ON

 

SET

OFF

 

CANCEL

 

TIMER

2

 

 

1

CHECK RESET CLOCK

1Press 1.

2Then press 2 to increase or decrease the time.

3Press 1 again.

Set time at display will light up.

HOW TO OPERATE

2

3

 

 

 

5

 

 

AUTO

 

 

 

 

 

 

ON

 

OFF

 

 

R

 

TIMER

 

ESET

CLO

 

 

 

 

 

 

CK

 

 

POW

ERFUL

 

 

 

 

MODE

 

 

 

AIR

SWING ECONOMY

 

 

 

 

MANUAL

 

 

SLEEP

2

FAN

 

 

 

SPEED

 

 

 

 

 

SET

CANCEL

 

A

 

 

UT

 

 

O

 

 

A

 

 

UT

 

 

O

A

 

FA

U

T

N

 

O

OFF/ON

1

6

4

To start the operation

Press 1.

POWER indicator (green) on the indoor unit will light up.

To stop, press once more.

Setting Mode

Press 2 to select:-

AUTO – Automatic Operation

COOL – Cooling Operation

DRY – Soft Dry Operation

FAN – Air Circulation Operation

Setting Temperature

Press 3 to increase or decrease the temperature.

The temperature can be set between 60°F ~ 86°F.

Recommended temperature:

COOL 75°F ~ 78°F

2°F ~ 4°F

DRY Lower than the room temperature

• During AUTO Operation, press 3 to select:-

• Operation with 4°F higher than the standard temperature.

• Operation with the standard temperature.

• Operation with 4°F lower than the standard temperature.

Standard Temperature

Indoor

Operation

Standard

temperature

temperature

 

Cooling

77°F

73°F

Soft Dry

72°F

Once the Automatic Operation is selected, the indoor temperature sensor operates automatically to select the desired operation mode with Cooling or Soft Dry.

After the operation mode has been selected, the mode does not change.

5

Setting the Fan Speed

• Press 4 to select:-

FAN

 

 

 

 

 

 

 

 

 

 

Low Fan Speed

FAN

 

 

 

 

 

 

 

 

 

 

Medium Fan Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN

 

 

 

 

 

 

 

 

 

 

High Fan Speed

 

 

 

 

 

 

 

 

AUTO

FAN – Automatic Fan Speed

The speed of the indoor fan is adjusted automatically according to the operation. The indoor fan stops occasionally during cooling operation.

Setting the Vertical Airflow Direction

• Press 5 or 6 to select:-

COOL / DRY Operation

FAN Operation

AUTO

 

AUTO

 

36°

 

 

61°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Swing up/down

Swing up/down

Automatically

Automatically

 

 

 

 

 

 

 

 

 

 

MANUAL

 

MANUAL

 

 

 

Five stages of adjustment

Five stages of adjustment

can be made between

can be made between

14° ~ 36°.

 

0° ~ 61°.

 

 

Setting the Horizontal Airflow Direction

• Adjust it manually

Notes

If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.5 W of electricity will be used even if the indoor unit has been turned off with the remote control.

If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes.

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum mode.

Temperature is not displayed on the remote control during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to dehumidification. It does not lower the room temperature.

During Soft Dry operation, the indoor fan operates at Low fan speed.

FAN – Air Circulation Operation

When the room temperature reaches the set temperature, operation commences at Low airflow volume. It stops when the room temperature drops to 4°F below the set temperature.

(It is useful when using a heater).

ENGLISH

6

8

POWERFUL

OFF/ON

 

7

MODE

ECONOMY

SLEEP

6

 

 

 

 

AIR SWING

 

 

 

AUTO

MANUAL

FAN SPEED

 

1

1

2

3

3

ON

 

SET

 

 

 

5

OFF

 

CANCEL

4

 

 

 

 

 

TIMER

 

2

SETTING THE TIMER

Ensure that the current time is correct before setting the timer. The timer cannot be set if the time display is flashing.

ON-TIMER Operation

To start the air conditioner operation automatically.

Press 1 to set the operation.

Press 2 to increase or decrease the time.

Then press 3.

To cancel this operation, press 4.

OFF-TIMER Operation

To stop the air conditioner operation automatically.

Press 5 to set the operation.

Press 2 to increase or decrease the time.

Then press 3.

To cancel this operation, press 4.

Timer Mode Operation Details

When the ON-Timer is set, operation will start before the actual set time. This is to enable the room temperature reaches the set temperature at the set time.

COOL, DRY,

15 minutes

AUTO

in advance

Once the ON-Timer is set, operation will start at the set time everyday.

The current time is not displayed when the timers are set.

When both timers are used together, the TIMER mode indicator on the indoor unit remains lit even when the operation is stopped by the OFF-TIMER.

CONVENIENCE OPERATION

Sleep Mode Operation

To obtain a comfortable room temperature while sleeping:-

Press 6.

Sleep mode indicator on the indoor unit will light up.

To cancel this operation, press once more.

Sleep Mode Operation Details

When the room temperature reaches the set temperature, the airflow volume will change to low automatically.

Sleep Mode Operation time is 8 hours.

When used together with the timer, the timer has a priority.

 

Temperature

S T

 

e e

 

t m

 

t

p

Sleep

i

e

r

Operation

n

a

button is

g

t

pressed.

u

 

r

0~1 hour

e

Approx. 1°F increase.

Sleep shift operation starts.

← 1 hour →

Approx. 1°F increase.

Cooling or Soft Dry Operation for sleep shift operation will start to avoid overcooling.

Time

after approx. 8 hours of sleep shift operation, it will stop automatically.

Economy Mode Operation

To save electrical power consumption.

Please use this mode when the room has reached your desired temperature.

• Press 7.

*Economy mode indicator (green) on the indoor unit will light up.

Press once more to cancel this operation.

Powerful Mode Operation

To obtain the set temperature quickly.

Press 8.

*Powerful mode indicator (orange) on the indoor unit will light up.

*Powerful mode will operate for 15 minutes only.

• To cancel this operation, press once more.

Economy / Powerful Mode Operation Details

• Economy and Powerful operation cannot be selected simultaneously.

• The changes of the temperature and airflow volume are automatic.

• The remote control display remains unchanged.

• If sleep button or operation mode button is pressed, economy or powerful operation will be cancelled.

• During FAN – Air circulation operation, the powerful and economy operation are not available.

 

Temperature

Airflow

 

 

volume

 

 

 

Economy Mode

1°F higher

Super Low

Operation

than set temp.

 

 

 

 

Powerful Mode

5°F lower

Super High

Operation

than set temp.

 

 

 

 

7

Loading...
+ 17 hidden pages