Safety

Safety
Please read and keep in a safe place
Operating instructions
Diaphragm gas meters BK-G.6 to BK-G5
© 2018 Elster GmbH · Edition 01.18

Contents

Contents
Translation from the German
Diaphragm gas meters
BK-G.6 to BK-G5 .....................
Contents ..............................
Safety.................................
Checking the usage .....................
Diaphragm gas meters BK-G1.6 to G25 ......2
BK with integrated “Smart Valve” ............2
Type code .............................2
Part designations ........................ 2
Type label/Index plate.....................2
ATEX identification .......................3
Installation ............................4
Temperature test point ..................5
Pressure test point on housing (optional) ...5
Connecting the piping ....................6
Pressure test point on outlet connector
(optional) ..............................6
Opening the test nipple ...................6
Closing the test nipple ....................6
Tightness test ..........................6
Commissioning.........................7
Maintenance/Removal...................8
Accessories ...........................8
Technical data .........................9
Declarations of conformity ..............0
ATEX legend ..........................14
Logistics .............................4
Contact ..............................4
Please read through these instructions
installation, pass the instructions on to the opera­tor. This unit must be installed and commissioned in accordance with the regulations and standards in force. These instructions can also be found at www.docuthek.com.
Explanation of symbols
• ,  ,  ,  ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from non-observance of the instructions and non-com­pliant use.
Safety instructions
Information that is relevant for safety is indicated in the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified gas technicians. Electrical interventions may only be carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM spare parts.
Changes to edition 07.7
The following chapters have been changed: – Checking the usage – Commissioning – Accessories – Technical data – Declarations of conformity – ATEX legend – Logistics
GB
GB-1
F
NL
I
SK
RUS
E
RO
SRB

Checking the usage

m
3
,
-
BK-G..M..
12345678
DE-07-MI002-PTB001 class 1,5
NG-47001BM0443 DIN EN 1359:2007
Q
max
Q
min
S/N: 002545632734 1 imp =^ 0,01 m
3
M ... 0102
Diaphragm gas meters BK-G.6 to G5
Residential or commercial diaphragm gas meters BK for recording gas consumption values for natural gas, town gas, propane and butane, as gases of the first to third families pursuant to DIN EN 437:2003 (DVGW Code of Practice G260). If used for internal
GB
measurements which are not subject to statutory testing, the gas meter is also suitable for hydrogen, nitrogen, air and inert gases.
The meters are designed for use in air at normal
atmospheric conditions. For use in other environ­ments, please contact the manufacturer (see also page 4 (Installation)).

BK with integrated “Smart Valve”

Not suitable for highly contaminated gases, e.g. town gas.
Potentially explosive atmosphere
Diaphragm gas meters that are labelled with
and (see sticker near the index) are suitable for operation in potentially explosive atmospheres, see page10 (Declarations of conformity).
The meter function is only guaranteed when used
under the specified operating conditions – see page 9 (Technical data). Any other use is con­sidered as non-compliant.

Type code

Code Description
BK-G Diaphragm gas meter
.6
.5 4
6 0 6
5
M
C
A
E
B
T
Te
TB
TeB
Chekker mechanical index Absolute ENCODER index
Indication of volume at base conditions
Temperature conversion:
mechanical-electronic temperature
conversion and pressure correction
electronic temperature conversion and
pressure correction
Flow rate
0.016 – 2.5 m
0.025 – 4 m3/h
0.04 – 6 m3/h
0.06 – 10 m3/h
0.1 – 16 m3/h
0.16 – 25 m3/h
0.25 – 40 m3/h
Mechanical index
Electronic index
mechanical
electronic

Part designations

6
4
7
5
2
3
1
Diaphragm gas meter BK
Index with index plate Connectors
4 Pressure test point to BS4161 (optional)
5 Protective caps 6 2 x thermowells (optional)
7 Pressure test point with sealing sleeve (optional)

Type label/Index plate

Please quote for all enquiries:
The manufacturer’s serial number S/N can be
found at the bottom of the type label.
The customer identification number is under the
barcode.
BK-G..M..
BK-G..M..
DE-07-MI002-PTB001
Q
max
class 1,5
Q
min
M ... 0102
S/N: 002545632734 1 imp =^ 0,01 m
3
BK-G..A.. with Absolute ENCODER index
/h
ENCODER VALVE Vs
M ... 0102
DE-07-MI002-PTB001
S/N: 002545632734
BK-G..E with index EI
BK-G..E..
Q
max
Q
min
V p
max
M ... 0102
S/N: ............ EI2. ...
BK-G..E with index EI4
BK-G..E
Q
max
Q
min
V p
max
class 1,5
M ... 0102
S/N: ............ EI4. ...
NG-47001BM0443 DIN EN 1359:2007
,
3
BK-G..A..
,
NG-47001BM0443 DIN EN 1359:2007
class 1,5
12345678
class 1,5 t
m
t
g
class 1,5 Valve Ve
t
m
12345678
t
g
t
b
12345678
3
m
-
3
m
-
^
...1 imp
=
GB-2
F
NL
I
SK
RUS
E
RO
SRB
BK-G..B with index EI
........
m g b
M ... 0102
15 ATEX 1550 X
BK-G..
m
,
-
BK-G..B
Q
max
t
m
Q
min
V
p
max
class 1,5
M ... 0102
S/N: ............
t
g
t
b
p
b
EI3. ...
V
b
12345678
BK-G..E with index EI5
BK–G6 E
M ...
= –20 °C ... +55 °C
gas
201x
t
m
t
g
Valve Ve
0102
II 3Gic c IIA T1Gc
Elster GmbH, Strotheweg 1 49504 Lotte, GERMANY
Elster GmbH, Strotheweg 1 49504 Lotte, GERMANY
BK–G6 ETe
201x
Q
max
Q
min
V p
max
DE-11-MI002-PTB001
class 1,5
t
= t
amb
16ATEX1551X
S/N: ............ EI5.0x
BK-G..ETe with index EI6
1 imp
12345678
12345678
Diaphragm gas meters with integrated valve
VALVE Vx
^
...
=
Valve variants: Vs = Smart Valve Ve = bi-stable valve with electronic flow rate testing
(with electronic index EI)
ATEX identification BK-G..M, BK-G..C, BK-G..MT, BK-G..CT
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/2 G c IIB TX
TÜV 11 ATEX 090370 X
Use as follows: Category, internal: none, external: 2 (Zone1).
Type of atmosphere: gases, hazes and vapours.
BK-G..M, BK-G..C, BK-G..MT, BK-G..CT with RFID passive tag
3
GB
t b
Q
max
t m
Q
min V p
max
DE-14-MI002-PTB003
class 1,5
Valve Ve
EI6.0xS/N: ...........
t
g IP
t
= t
amb
15ATEX1550X
M ...
= –25 °C ... +55 °C
gas
0102
GPRS
II -/3 G IIB T4
BK-G..E.. and BK-G..B
The following data is not necessarily specified on
the type label/index plate, but can be called up in the menu:
– specified centre temperaturetsp (for meters with
temperature conversion only), – EN 1359 registration number (if available), – firmware version.
A number of variants are available for the elec tronic indexes. The EIx.xx ID of the index variant can be found at the bottom of the type label or on the index cover next to the serial number S/N.
Further information can be found in the supplemen­tary operating instructions of the relevant index.
Use as follows: Category, internal: none, external: 2 (Zone 1).
Type of atmosphere: gases, hazes and vapours.
BK-G..A, BK-G..AT
-
Use as follows: Category, internal: none, external: 2 (Zone1).
Type of atmosphere: gases, hazes and vapours.
GB-3
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/2 G IIB T4
Ui=5,5V Ii=30mA Pi=33mW Ci=140µF Li=0µF
F
NL
I
SK
RUS
E
RO
SRB
BK-G..E, BK-G..ET, BK-G..ETB with index EI
Elster GmbH, Strotheweg 1 49504 Lotte, GERMANY
Category  devices:
Elster GmbH, Strotheweg 1
BK
GB
Use as follows: Category, internal: 3 (Zone 2), external: 1 (Zone 0).
Type of atmosphere: gases, hazes and vapours.
For the ambient and gas temperatures of the ATEX
Zones, see illustration.
Category  devices:
BK
D-49504 Lotte, Germany
II 3/1G IIB T4
0044
= t
t
amb
TÜV 14 ATEX 143120 X
Elster GmbH, Strotheweg 1 D-49504 Lotte, Germany
= –20 °C ... +55 °C
gas
II -/3 G IIA T1
13 ATEX 1389 X
Use as follows: Category, internal: none, external: 3 (Zone2).
Type of atmosphere: gases, hazes and vapours.
BK-G..B
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/2 G IIA T4
TÜV 12 ATEX 098560 X
Use as follows: Category, internal: none, external: 2 (Zone1).
Type of atmosphere: gases, hazes and vapours.
BK-G..E with EI5
0102
M ...
t
= t
amb
16ATEX1551X
= –20 °C ... +55 °C
gas
II 3Gic c IIA T1Gc
S/N: ............ EI5.0x
Use as follows: Category: 3 (Zone 2).
Type of atmosphere: gases, hazes and vapours.
BK-G..ETe with EI6
t b t m
t
g
IP
Valve Ve
M ...
t
= t
amb
EI6.0x
Use as follows: Category, internal: none, external: 3 (Zone 2).
Type of atmosphere: gases, hazes and vapours.
gas
18ATEX1678 X
GPRS
0102
II -/3 G ic c IIB T4 Gc
= –25 °C ... +55 °C

Installation

WARNING
Please observe the following to ensure that neither
persons nor the gas meter are damaged during installation and operation:
– Note the max. allowable operating pres-
surep page2 (Type label/Index plate).
– Note the permitted ambient temperaturetm and
gas temperaturetg, see page2 (Type label/ Index plate) or page9 (Technical data).
– The gas meters are certified for mechanical
environments pursuant to Class M1 of Directive 2004/22/EC. When installed, the meters must not be subject to permanent vibration such as that caused by machines in the vicinity. In case of doubt, vibration isolation must be provided. For gas meter versions BK..A, BK..E and BK..B, ClassE2 for electromagnetic environments also applies.
– The dangers of chemical reactions between
gas meter parts and the chemical substances in the environment are to be discussed by the manufacturer and the operator and must be eliminated.
– When installing the diaphragm gas meterBK with
integrated valve, make sure that no dirt particles get into the meter and thus into the valve.
– The yellow sealing sleeve protects the pressure
test point on the gas meter. It may only be opened for connecting a pressure measuring line.
– Use seals made from tested materials. Elastomer
seals or asbestos-free flat seals from Elster are
recommended. – Only use the seals once. – For meters resistant to high temperatures, only
use seals tested to be resistant to high tempera-
tures.
and measuring rangeQ
max
max
, see
GB-4
F
NL
I
SK
RUS
E
RO
SRB
– For installation and operation, note the applicable
1 2
national regulations and the directives of the gas supply company. For Germany, the valid DVGW Code of Practice G600 (DVGW-TRGI) applies.
– Work on meters and the installation of meters
which are marked with and are installed in potentially explosive atmospheres may only be carried out by persons with appropriate qualifi­cations.
– The gas meter marked with must be in-
cluded in the equipotential bond when being
installed in a potentially explosive atmosphere,
e.g. by connecting it to a grounded pipeline. Installation must be carried out in accordance with EN60079-14.
– The gas meter marked with must be pro-
tected from falling parts.
– Avoid subjecting the unit to mechanical stress
and prevent damage. Gas meters must be in­stalled without any mechanical stress, preferably only by suspending them on the connectors. When using additional clamps, it must be en­sured that no lateral forces act on the gas meter.
These can be avoided by using flexible or supple
connection lines, for instance.
▷ If the calibration seal has been damaged or re-
moved, the gas meter is no longer approved for measurements which are subject to statutory testing.
▷ If the gas meter is stored or installed outdoors,
protect the site against rain. Condensing humid-
ity is permitted.
▷ Meters which are marked with H3 are suitable
for installation outdoors without additional pro­tection.
Remove protective caps.
Installation in the vertical position: connectors must be pointing upwards.
Note direction of flow (arrow). The gas meter must not be in contact with ma-
sonry or other parts.
Ensure that there is sufficient installation space. Ensure unobstructed view of the index.
The seal faces on the screw unions must be
clean and damage-free.
▷ Ensure that the seal is correctly seated.
Co-axial meters:
▷ The seal must be centred over the internal dia-
meter.
Note the installation position of the pressure ring.
The inner beaded edge must point upwards.
▷ Replace damaged pressure rings when replac-
ing the meter.
Co-axial and two-pipe meters:
▷ For the compression of seals and the resulting
tightening torques for the screw unions, the seal
manufacturers’ specifications must be observed.
Tightening torques for the recommended flat
seals in conjunction with screw connectors pursuant to DIN 3376-1 and 3376-2, see
www.docuthek.com → Elster-Instromet Prod-
ucts Gas measuring devices Diaphragm
meters Ergänzung für Betriebsanleitung BK, Verschraubungen und Anzugsmomente für BK­G1,6 bis BK-G25 (Supplement to BK operating
instructions, Screw unions and tightening tor-
ques forBK-G1.6 toBK-G25)(D).
Install the gas meter free of mechanical stress.
If a pulse transmitter IN-Z6x is used for pulse tapping on the gas meter marked with – see
Data sheet for pulse transmitter IN-Z6x (D,GB) www.docuthek.com→ Elster-Instromet Prod-
ucts Gas measuring devices Diaphragm
meters Pulse transmitterIN-Z61 and the
standard EN60079-14 (Explosive atmospheres).

Temperature test point

Temperature sensors can be inserted into the thermowells for measuring the gas temperature
in the meter housing.
Secure each of the temperature sensors using
the capstan screw provided.

Pressure test point on housing (optional)

GB
When using an elastomer seal, always use a pressure ring (shape A).
GB-5
Loading...
+ 9 hidden pages